![Nikkor JAA79051 Repair Manual Download Page 37](http://html1.mh-extra.com/html/nikkor/jaa79051/jaa79051_repair-manual_1689440037.webp)
Additional page
JAA79051-R.3624.A
- L28-7・ AF-S DX18-70/3.5-4.5G -
January. 28. 2005
(4) 4th lens group alignment (Center alignment)
①
Remove the alignment screwdrivers (long, middle, short) from the equipment (for periphery) and insert them
into the equipment (for center). Then move the holder-moving lever up to lock the holder.
②
Mount the lens on the equipment (for center) (ref.
①
of (3) for how to fit in it.), and set the zoom ring to
TELE-end (70-mm side).
③
Remove the both cable that connects the VIDEO terminal of the CCD camera and the fiber-optic cable that
connects MEGALIGHT 100 from the equipment (for periphery), then connect them to the equipment (for
center). Turn the "LIGHT CONT." knob of MEGALIGHT 100 to adjust brightness, and turn the focus ring
to adjust the shape of the pinhole on the monitor. (ref. Pic.1 for the image of the pinhole.)
Pic.1
CCD camera
VIDEO cable
Fiber-optic cable
INC