JAA79051-R.3624.A
- L30 ・ AF-S DX18-70/3.5-4.5G -
PREPARATION FOR INSPECTION AND ADJUSTMENT OF MAIN PCB
●
In case of replacing the main PCB, SWM unit or MR encoder unit, be sure to adjust the followings:
1.
Adjustments
・
Adjustment of MR duty
・
Adjustment of driving frequency and motor control
2.
Equipment and tools required
・
Single output rated voltage power supply: 1 unit
6.0V 3.0A
・
Oscilloscope: 1 unit for adjusting the MR duty/adjusting the driving frequency and motor control
・
AF-I communication box (J15306 or J15306-1): 1 unit
・
AF-I communication adapter (J15307): 1 unit
INC