background image

Bayco Products, Inc. • 640 South Sanden Blvd. • Wylie, TX 75098 • 1-800-233-2155 • 1-469-326-9400 • www.nightstick.com

INS-XPR-5568-DL-20

04-03-2020

contacts  on  it  being  inserted  first  and  the  rails  on  the  bottom  of  the  Battery  Pack 

positioned toward the back of the light.

 

y

With the 5568-BATT Lithium-ion Rechargeable Battery Pack fully inserted into the 

handle of the light, close the Battery Compartment Door and secure it in place with the 

Battery Compartment Door Screw.

WARNING: Do not over-tighten the Battery Compartment Door Screw.

The Angle Light is now ready to be powered using the Nightstick 5568-BATT Lithium-

ion Rechargeable Battery Pack.

5566-CARRIER NON-RECHARGEABLE BATTERY CARRIER

WARNING: The Nightstick 5566-CARRIER Non-Rechargeable Battery Carrier is a 

proprietary shape and design and will only fit in the XPP-5562, XPR-5564, XPP-

5566, and XPR-5568 Angle Lights. Do not attempt to use this battery pack in any 

other light. Do not attempt to use any other battery pack in this light.

The Nightstick 5568-CARRIER Non-Rechargeable Battery Carrier is designed to 

fit 3 AA batteries. In order to maintain the XPR-5568’s Intrinsically Safe rating, the only 

AA batteries certified for use with this light are the 

Energizer EN91

 or 

Energizer E91

.

Do not attempt to use any other brand or model of AA batteries with this light.
Do not attempt to use any type of rechargeable AA batteries with this light.

Installing or replacing the batteries

 

y

Begin by positioning the 5566-CARRIER Non-Rechargeable Battery Carrier with the 

arrow pointing to the left.

 

y

Using 3 – AA 

Energizer EN91

 or 

Energizer E91

 (make sure that all 3 batteries are 

of one or the other model…do not use a combination of the two), install the batteries 

per the diagram located on the base of the battery carrier.

 

y

Take care not to bend any of the battery contact springs, and to make sure that all 3 

batteries are properly seated before installing into the angle light. 

NOTE: The battery carrier cover will only fit one way. It is not possible to install it 

in a reversed position.

The Nightstick 5566-CARRIER Non-Rechargeable Battery Carrier is ready to 

install into the Angle Light. Installation of the 5566-CARRIER Non-Rechargeable 

Battery Carrier into the Angle Light is the same as installing the 5568-BATT Lithium-ion 

Battery Pack. Please see the instructions listed above in the 

5568-BATT LITHIUM-ION 

RECHARGEABLE BATTERY PACK

 section.

PLACING THE ANGLE LIGHT INTO THE CHARGER

The Nightstick 5568-CHGR1 charger is designed to securely hold a properly installed 

XPR-5568 Angle Light in place under conditions up to and including 9g of lateral force 

meeting the requirements of NFPA 1901 (2009). 

WARNING: Installing the Angle Light into the charger MUST be done using the 

following steps. Failure to do so could damage the charger or its ability to hold 

the Angle Light securely in place.

The spring-loaded tab located on the bottom of the charger, is designed to hold the 

bottom base of the Angle Light securely in place.

 

y

Firmly grip the Angle Light in one hand and press the bottom of the Angle Lights base 

downward onto the black spring-loaded tab and then push the base of the Angle Light 

forward into the charger until it slips past the spring-loaded tab and snaps into the charger.

Confirmation of proper installation can be seen in the LED Charge Indicator Light. 

When the Angle Light is properly installed in the charger, and power is being supplied by 

the Nightstick AC or DC Power Supply, the LED Charge Indicator Light on the charger 

will light up constant RED indicating that the unit is being charged.

REMOVING THE ANGLE LIGHT FROM THE CHARGER

 

y

Firmly grip the Angle Light and pull straight back from the charging cradle. 

 

y

NO NEED TO PRESS BUTTON to disengage light from charging base.

CHARGING THE ANGLE LIGHT

WARNING: Use only the supplied Charger, Lithium-ion Rechargeable Battery Pack 

and AC or DC Power Supply for charging. Do not attempt to charge this light with 

non-rechargeable or rechargeable AA batteries installed.

 

y

The time required to charge the Angle Light is conditional on the remaining charge 

left in the Lithium-ion Rechargeable Battery Pack at the time of charging. The maximum 

charge time required is approximately 6 hours.

 

y

Fully charge the Lithium-ion Rechargeable Battery Pack before the first use, or if the 

Lithium-ion Rechargeable Battery Pack has been unused for several months. 

 

y

Install the Angle Light into the charger using the exact method described in this 

Instruction Manual above (“

PLACING THE ANGLE LIGHT INTO THE CHARGER”

). 

WARNING: Failure to do so could damage the charger and/or the light.

 

y

When the Angle Light is properly seated in the charger, the LED Charge Indicator 

light will turn solid RED indicating that the Lithium-ion Rechargeable Battery Pack is 

charging. The Lithium-ion Rechargeable Battery Pack is fully charged when the LED 

Charge Indicator light turns GREEN.

 

y

The Lithium-ion Rechargeable Battery Pack does not have any Recharge Memory 

Effect, therefore placing the Angle Light in the charger prior to full depletion of the 

battery does not adversely affect the battery life. The Angle Light can be kept in the 

charger indefinitely without any negative impact on the battery or the battery life.

OPERATION

THE XPP-5568 HAS 8 SEPARATE LIGHTING MODES:
Flashlight Modes

To activate the Flashlight, press and release the Flashlight Switch. The default mode 

will be High-brightness. To select the brightness level for the Flashlight, press and hold 

the Flashlight Switch. The flashlight will cycle from high to medium to low

 

at a rate of 

approximately one mode per second. The light will continue to cycle through the various 

modes as long as the switch is held down. When the desired brightness level is reached, 

release the Flashlight Switch and the light will remain in that brightness mode. To turn the 

Flashlight off, press and release the Flashlight Switch one more time.

Strobe

To activate the Strobe, double click the Flashlight Switch. To turn the Strobe off, 

press and release the Flashlight Switch one more time.

Floodlight Modes

To activate the Floodlight, press and release the Floodlight Switch. The default mode 

will be High-brightness. To select the brightness level for the Floodlight, press and hold 

the Floodlight Switch. The floodlight will cycle from high to medium to Survival at a rate of 

approximately one mode per second. The light will continue to cycle through the various 

modes as long as the switch is held down. When the desired brightness level is reached, 

release the Floodlight Switch and the light will remain in that brightness mode. To turn 

the Floodlight off, press and release the Floodlight Switch one more time.

Dual-Light Mode

Dual-Light mode allows the user to turn on both the Flashlight and the Floodlight 

at the same time. Dual-Light mode can be activated by simply pressing the Flashlight 

Switch and then the Floodlight Switch at the same time. If the Angle Light already has 

the Flashlight or the Floodlight on (regardless of what brightness mode that light is in), 

pressing the switch for the light that is NOT on, will activate Dual-Light mode. The user 

can leave Dual-Light mode and go back to either Flashlight or Floodlight mode simply by 

pressing the switch for the mode that they wish to turn off. To turn both lights off, simply 

press each of the switches independently.

WARRANTY 

LIMITED LIFETIME WARRANTY

Bayco Products, Inc. warrants this product to be free from defects in workmanship 

and materials for the original purchaser’s lifetime. The Limited Lifetime Warranty 

includes the LEDs, housing and lenses. Rechargeable batteries, chargers, switches, 

electronics and included accessories are warranted for a period of two years with proof 

of purchase. Normal wear and failures which are caused by accidents, misuse, abuse, 

faulty installation and lightning damage are excluded.

We will repair or replace this product should we determine it to be defective. This 

is the only warranty, expressed or implied, including any warranty of merchantability or 

fitness for a particular purpose.

For a complete copy of the warranty, go to www.baycoproducts.com/bayco-product-

support/warranties. Retain your receipt for proof of purchase.

Mode D’emploi

 

Intrant

®

 

XPR-5568

Veuillez lire ces directives avant d’utiliser votre lampe à angle admissible 

rechargeable Nightstick XPR-5568 à sécurité intrinsèque. Elles contiennent des 

renseignements importants et des consignes d’utilisation.

LA LAMPE XPR-5568 EST APPROUVÉE POUR UTILISATION

CLASS I DIV 1 GRPS A-D T4
CLASS II & III DIV1 GRPS E-G T135°C
CLASS I ZONE 0 AEx ia IIC T4 Ga

Ex ia op is I Ma
Ex ia op is IIC T4 Ga
DEMKO 17 ATEX 1927
IECEx UL 17.0082
-20ºC ≤ Tamb ≤ +40ºC
1.5V/Cell Alkaline
3.7V/Cell Li-ion
IP-67
Um: 10V

2575

INTRINSICALLY SAFE

SECURITE INTRINSEQUE

I M1 Ex ia op is I Ma
II 1 G Ex ia op is IIC T4 Ga

E 467756

Bayco Products, Inc.     XPR-5568

Ex ia FLASHLIGHT FOR USE IN HAZARDOUS LOCATIONS

For use with Bayco Li-ion Battery Pack 5568-BATT or 

5566-CARRIER with 3 AA Energizer Type EN91 or E91 

batteries only  

ELECTRICAL SAFETY

640 S. Sanden Blvd., Wylie, TX 75098

Control Drawing: 5568-CERT-DWG1-03

ID 4003544

INMETRO

Segurança

NCC

Ex ia op is I Ma

Ex ia op is IIC T4 Ga (-20ºC ” Tamb ” +40ºC)

18.0110 X

AVERTISSEMENTS – SÉCURITÉ INTRINSÈQUE

 

y

AVERTISSEMENT: Utiliser uniquement le bloc-piles approuvé Nightstick 5568-BATT 

au lithium-ion rechargeable ou les piles non rechargeables approuvées et énumérées 

dans le point 4 des conditions particulières d’utilisation. 

Summary of Contents for Intrant XPR-5568

Page 1: ...design and will only fit in the XPP 5562 XPR 5564 XPP 5566 and XPR 5568 Angle Lights Do not attempt to use this battery pack in any other light Do not attempt to use any other rechargeable battery pa...

Page 2: ...ight is properly seated in the charger the LED Charge Indicator light will turn solid RED indicating that the Lithium ion Rechargeable Battery Pack is charging The Lithium ion Rechargeable Battery Pac...

Page 3: ...eur a t install sur une cloison s che vous aurez besoin d installer 4 vis d ancrage comprises En utilisant un fleuret percer 4 trous travers la cloison s che l emplacement des marques de clou En utili...

Page 4: ...l interrupteur lampe de poche La lampe de poche passera d un cycle de luminosit allant d une lumi re haute moyenne mode bas et puis recommencera une vitesse d environ un mode par seconde L clairage c...

Page 5: ...stala en una superficie met lica taladre 4 orificios de tama o adecuado El di metro de la broca requerida estar determinado por el tipo de metal y el espesor del material NOTA Si el cargador est siend...

Page 6: ...resione y suelte el interruptor del Reflector el modo predeterminado ser Alto Brillo Para seleccionar el nivel de brillo del Reflector mantenga pulsado el interruptor del Reflector El reflector cambia...

Page 7: ...steja firmemente afixado na superf cie de montagem CUIDADO N o use uma furadeira el trica ou broca para instalar os parafusos N o aperte demais Isso pode danificar os orif cios de montagem no carregad...

Page 8: ...rrer os v rios modos enquanto o interruptor for pressionado Quando o n vel de brilho desejado for alcan ado basta soltar o bot o do Floodlight e a luz permanecer nesse modo de brilho Para desligar o F...

Page 9: ...r k nnen oberhalb des Ladeger tes erreicht werden wenn die Winkellampe nicht in das Ladeger t eingef hrt ist y Indem Sie durch die Befestigungsl cher auf der Vorderseite des Ladeger tes schauen gleich...

Page 10: ...Die XPP 5568 hat acht separate Beleuchtungsarten y Hohes Helligkeits Blinklicht y Mittleres Helligkeits Blinklicht y berlebensmodus Blinklicht y Stroboskop Blinklicht y Hohes Helligkeits Flutlicht y M...

Page 11: ...GX RX Type Flashlight ATEX Directive 2014 34 EU The following harmonised standards and technical specifications have been applied Evaluated to the following safety standards by Underwriters Laborator...

Reviews: