B.6 Gas Connection- 3/4” N.P.T.

At rated input the gas supply should deliver a minimum pressure of at least 15 mbar (6" water column)
at the broiler connection for natural gas. Incoming gas supply pressure must not exceed 50 mbar (14"
water column).

Note

: The installation of this appliance must conform with local codes, or in the absence of local codes,

with the National Fuel Gas Code, ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1
including:

1. The appliance and its individual shutoff valve must be disconnected from the gas supply
piping system during any pressure testing of that system at test pressures in excess of
1/2 psi (3.45 kPa).

2. The appliance must be isolated from the gas supply piping system by closing its
individual manual shutoff valve during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 psi (3.45 kPa).

B.7 Installing Gas Appliance Connectors and Flexible Gas Lines Correctly

For safety in the kitchen area, and to insure maximum service life, it is vitally important to correctly install
connectors. The connector shall comply with the Standard for Connectors for Moveable Gas Appliances,
ANSI Z21.69 or CAN/CGA-6.16 and a quick disconnect device that complies with the Standard for Quick-
Disconnect Devices for use with gas fuel, ANSI Z21.41 or CAN1-6.9

In order to avoid sharp kinks or excessive bends that could have a damaging effect on the connector, it
may be necessary to attach pipe elbows in order to bring the connector into its proper plane. For easy
movement of the appliance, the connector should be installed with a "lazy" loop for minimum tension.

Note: Gas appliances should be disconnected prior to maximum movement. (Minimal movement is
possible to connect hose.)

B.8 Restraining Device Installation and Use

This high strength restrainer is to be used with all moveable (castered) appliances. It fully complies with
American Gas Association requirements. References: Z21.69, Z83.11, and Z21.41 with current revisions.
Installation is quick and positive. In Canada, device is in accordance with CAN 1-6.9-M70 Quick
Disconnect Devices for use with gas fuel, and CAN 1-6.10-88 metal connectors for gas appliances.
Correct length for any appliance is simply a matter of loosening two adjuster clips (1) and re-tightening.
(3" to 6" shorter than appliance connector is desired length.) Restrainer is made of heavy duty steel
cable, with a strong scissor hood (2) at one end, and an equally strong spring hook (3) at the other.
Cotter pin (4) is supplied to secure the installation. For proper attachment to the broiler, use the supplied
hardware to attach the device to the holes in the shear plate of the broiler stand.

NOTE: If disconnection of the restraint is necessary, reconnect the restraint after the appliance

has been returned to its originally installed position.

Nieco Corporation - Model MPB73

Summary of Contents for MPB73

Page 1: ...store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance APPROVALS IMPORTANT RETAIN THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE Updated 6 3 08 Br...

Page 2: ......

Page 3: ...ements 6 B 5 Clearance 6 B 6 Gas Connection 7 B 7 Flexible Gas Line Installation 7 B 8 Restraining Device 8 B 9 Electrical Connection 8 B 10 Pre Operation Check 8 C Operation 9 C 1 Controls and Indica...

Page 4: ...amage claims are the responsibility of the purchaser and ARE NOT covered under warranty The warranty does not extend to Damages caused in shipment or damage as a result of improper use Installation of...

Page 5: ...has been factory trained and has a complete supply of parts for your Nieco Automatic Broiler You may contact the factory direct at 707 284 7100 if you have trouble locating your local Nieco Distributo...

Page 6: ...ts The Nieco Corporation does not endorse the use of any particular cleaning degreasing agent Use only those chemicals that are approved for use your kitchen The broiler should be grounded according t...

Page 7: ...f adequate size and the following minimum capacity Do not obstruct the flow of combustion and ventilation air An adequate air supply must be available for safe and proper operation For installations i...

Page 8: ...In order to avoid sharp kinks or excessive bends that could have a damaging effect on the connector it may be necessary to attach pipe elbows in order to bring the connector into its proper plane For...

Page 9: ...e of local codes with the National Electrical Code ANSI NFPA 70 or the Canadian Electrical Code CSA C22 2 as applicable Before starting broiler tighten all electrical connections in control box An ele...

Page 10: ...turn to set cook times Load Sensing Control Use to calibrate broiler and set temperature Main On Off Switch Push up to turn on down to turn off On Off Indicator Light Broiler is on when illuminated ON...

Page 11: ...fter the third attempt the ignition failure light will flash and the main on off switch must be cycled to repeat the procedure If this still doesn t light the broiler see the MANUAL IGNITION instructi...

Page 12: ...ol C 3 Shutdown Procedures PLANNED SHUTDOWN 2 Close the MAIN GAS VALVE b Valve is closed when it is perpendicular to pipe EMERGENCY SHUTDOWN 1 Turn off the MAIN POWER SWITCH Your Nieco Automatic Broil...

Page 13: ...ng control This control will detect when your broiler is getting too hot and will lower the gas pressure to help cool the broiler down in the event of a flare up The control is factory set and does no...

Page 14: ...sembly CAUTION Follow the Disassembly and Reassembly steps to ensure proper operation of the broiler Failure to do so may result in operational problems WARNING BROILER PARTS ARE HOT DO NOT ATTEMPT TO...

Page 15: ...crub Pad Towel Heat Resistant Gloves Degreaser Soft Bristle Brush Utility Knife Small Orifice Brush Shaft Cleaning Tool Tools Needed 1 2 This Stop sign shows a step in the procedure that must be follo...

Page 16: ...ad Slide grease pan out Make sure grease pan is cool before putting in water or it may warp the pans Take to sink area and spray with degreaser Wash with a scrub pad rinse and sanitize in the 3 compar...

Page 17: ...warp Discharge Pan Insert P N 17605 Discharge End Tools Instructions Clean Per Shift 3 Compartment Sink Degreaser 1 2 3 4 Green Scrub Pad Dip Tank If Applicable Lift discharge pan up and off slots Tak...

Page 18: ...tions Dishwasher Clean Twice daily 1 2 3 Green Scrub Pad 4 Tilt stripper blade away from chain lift off brackets Make sure stripper blade is cool before putting in water or it may warp Take to sink ar...

Page 19: ...roiler Wipe shaft cleaning tool with a towel Do not run the broiler while cleaning the shafts Clean only the part that is accessible Chain Shafts Discharge End Tools Instructions Clean Daily 1 Shaft C...

Page 20: ...urner are facing up Burners must be completely dry before reassembly Lower Burners P N 16974 Double 17622 Single Side Tools Instructions Clean Weekly Heat Resistant Gloves 1 2 3 4 5 Scrub Pad From the...

Page 21: ...T Be careful not to burn yourself Grasp handle and lift Catalyst off to remove from Shroud SOAK IN WARM WATER FOR 1 HOUR RINSE WITH WATER ONLY NEVER USE ANY CHEMICALS ON THE CATALYST Lay flat to drain...

Page 22: ...ctions Clean Weekly 3 Compartment Sink Scrub Pad Heat Resistant Gloves Degreaser 1 CAUTION Extremely Hot 2 3 Lift each burner up and out of broiler Take to the 3 compartment sink and scrub with a scru...

Page 23: ...23 Nieco Corporation Model MPB73 Clean orifices using a small dry orifice brush Orifices P N 14041 41 Upper and lower Inside Tools Instructions Small Orifice Brush Clean Monthly 1 Burner Orifice...

Page 24: ...reverse buttons located on the side of the control box to help clear a belt jam Check the stripper blade to make sure it is installed properly Feeder belt not moving Make sure the feeder is assembled...

Page 25: ...25 Nieco Corporation Model MPB73 F PARTS LOCATION DRAWINGS Feed End View...

Page 26: ...Discharge End View 26 Nieco Corporation Model MPB73...

Page 27: ...era tion of your broiler G SPECIFICATIONS AUTOMATIC BROILER Model MPB73 DIMENSIONS INCH MM Length 28 50 724 Height 31 33 796 Width 37 21 945 ENERGY GAS MODELS Gas connection 3 4 N P T Electrical conne...

Page 28: ...Nieco Corporation 7950 Cameron Drive Windsor CA 95492 707 284 7100 Office 707 284 7430 Fax www nieco com e mail service nieco com Printed in the USA 2007 Nieco Corporation...

Reviews: