background image

17 

Specifications 

1-1  General Specifications 

 
LCD display digits :  

3 1/2 digit large scale LCD readout. 

Display count : 

2000 counts. 

Measuring rate : 

1.5 times / sec. 

Overrange display : 

“OL” is displayed for 

Ω

” functions, shows the real value for “A” 

and “V” function. 

Automatic power off time :  

Approximately 10 minutes after power on.  

Low battery indicator : 

=

 is displayed.  

Power requirement : 

1.5V x 2 batteries  

Battery life : 

ALKALINE 200 hours  

 

1-2  Environmental Conditions 
Indoor Use. 
Calibration : 

One year calibration cycle. 

Operating temperature :  

0°C ~ 30°C (

80% RH)  

30°C ~ 40°C (

75% RH)  

40°C ~ 50°C (

45%RH) 

Storage temperature : 

-20 to +60°C, 0 to 

80% RH (batteries not fitted). 

Overvoltage category :  

IEC 61010-1 600V CAT.

 

CAT         Application field 

 

The circuits are not connected to 

mains. 

 

The circuits are directly connected to 

Low-voltage installation. 

 

The building installation. 

 

The source of the Low-voltage 

installation. 

Operating altitude : 

2000m (6562 ft)

 

Conductor Size : 

27mm diameter. 

Pollution degree : 

2  

EMC : 

EN 61326-1

    

Shock vibration : 

Sinusoidal vibration per 

MIL-T-28800E (5 ~ 55 Hz, 3g maximum).

 

Summary of Contents for NI 03

Page 1: ...NI 03 Stroomtang Multimeter...

Page 2: ......

Page 3: ...gespecificeerd in de handleiding anders kan de bescherming door de stroomtang niet worden gegarandeerd Maak gebruik van individuele bescher mingsmiddelen wanneer risicovolle onderdelen in de te meten...

Page 4: ...2 Aan Uit Automatische uitschakeling De stroomtang schakelt zichzelf automa tisch uit ca 10 minuten nadat deze is aangezet...

Page 5: ...3 AC V DC V Weerstand Los Uit Ontlaad High Voltage Capacitor...

Page 6: ...4 Doorgang Vasthouden data Druk...

Page 7: ...CA CAT 600V met van de de stroomtang Berscherm barri re voor veilig vasthouden Houdt de meter niet voorbij de Vervanging batterij I I I I OK OK OK I I 0 betrekking tot de bek t o v de aarde barri re v...

Page 8: ...Alkaline 200 uren 1 2 Omgevingsvoorwaarden Gebruik binnenshuis Kalibratie 1x per jaar Werkingstemperatuur 0 C 30 C 80 relatieve vochtigheid 30 C 40 C 75 relatieve vochtigheid 40 C 50 C 45 relatieve v...

Page 9: ...keurigheid C 18 28 DC AC Spanning Bereik DC Nauwkeurigheid AC Nauwkeurigheid 200 0V 1 0 2dgt 600V 1 5 5 dgt 50Hz 500Hz Overspanningsbeveiling 600V AC DC Invoer impedantie 10M 100pF CMRR NMRR Common Mo...

Page 10: ...liging 600V rms Open circuit Spanning Ca 1 3V 1 100 dgt rollen 2 10 dgt rollen 3 de maximale LCD weergave is 1400 tellen Doorgang Interne pieper activeert wanneer de weer stand van het te testen circu...

Page 11: ...ons verholpen indien het instrument zonder invloed van buitenaf en ongeopend aan ons retour wordt gestuurd Beschadigingen voortkomend uit het laten vallen of incorrect gebruik vallen buiten de garant...

Page 12: ...V Vrieslantlaan 6 3526 AA Utrecht P O Box 7023 3502 KA Utrecht The Netherlands Tel 31 0 30 288 13 11 Fax 31 0 30 289 88 16 E mail sales nieaf smitt nl Internet http www nieaf smitt nl http www nieaf...

Page 13: ...11 NI 03 Clampmeter...

Page 14: ...Meter might be impaired Individual protective device must be used if hazardous live parts in the installation where the measurement is to be carried out could be accessible Symbols as marked on the T...

Page 15: ...13 Power On Off Auto Power Off The meter will automatically shut itself off after approximately 10 minutes after power on...

Page 16: ...14 ACV DCV Resistance...

Page 17: ...15 Continuity Data Hold...

Page 18: ...16 ACA CAT 600V with respect to earth for the jaw Tactile Barrier for hand guard Do not hold the meter across the Tactile Barrier I I I I OK OK OK I I 0 Battery Replacement...

Page 19: ...2 Environmental Conditions Indoor Use Calibration One year calibration cycle Operating temperature 0 C 30 C 80 RH 30 C 40 C 75 RH 40 C 50 C 45 RH Storage temperature 20 to 60 C 0 to 80 RH batteries n...

Page 20: ...s Range DC Accuracy AC Accuracy 1 0 2dgt 1 5 5dgt 50Hz 500Hz 200 0V 600V Over voltage protection DC AC 600V Input Impedance 10M less than 100pF CMRR NMRR Common Mode Rejection Ratio Normal Mode Reject...

Page 21: ...pen circuit Voltage 1 3V approx 1 100 dgt rolling 2 10 dgt rolling 3 The maximum LCD reading is 1400 counts Continuity Internal beeper activates if the resistance of the circuit under test is less tha...

Page 22: ...nt unauthorized repair alteration contamination or abnormal conditions of operation or handling Any implied warranties arising out of the sale of this product including but not limited to implied warr...

Page 23: ......

Page 24: ...V Vrieslantlaan 6 3526 AA Utrecht P O Box 7023 3502 KA Utrecht The Netherlands Tel 31 0 30 288 13 11 Fax 31 0 30 289 88 16 E mail sales nieaf smitt nl Internet http www nieaf smitt nl http www nieaf i...

Reviews: