8
Precautions for the air-cooled pump unit
・ When removing the radiator, drain oil first, and remove the outlet/inlet pipes, four supporting bolts (6 x 15), two pan head screws on the fan side
(4 x 50), fan, and then motor, in this order. If a large amount of oily dust is attached to the radiator, soak in a warm water solution with dissolved
neutral detergent, and rinse in water. After that, blow compressed air on it.
・ Clean oil deposit using solvent (Trichloroethylene) approximately once a year
(Deteriorated oil will be dissolved gradually in the solvent. Leave solvent inside for approximately 30 minutes).
・ When the detector indication ring turns yellow, remove the cover on top of the filter,
and clean the element using light oil, etc.
Precautions for the water-cooled pump unit
・ Check that water is always running in the oil cooler pump unit.
・ If there is a risk of water freezing due to being in cold regions, a time of extreme
cold, or when interrupting operation, remove the drain plug of the pump unit, and
drain the water from it.
・ Since accumulated water deposit inside the pump unit could result in a decrease in
cooling function, clean the cooling water conduit once a year.
Note : When cleaning the water conduit, remove the water chamber covers on both sides.
Oil filter
Water chamber cover
Cooling wat
er outlet
Inlet openings
Cooling water drain plug
(White) Danger
(Yellow) Clean the element
(Blue) Normal
Detector
● When using the product at especially low temperatures (approximately -30ºC to 0ºC) or high temperatures (approximately 40ºC or more), heat or cold-
resistant lubricating oil and applicable internal parts are required. For details, consult us in advance.
● For purchase of special traction drive oil, contact us or any of the ENEOS Corporation offices.
■ Speed change section
For special traction drive oil, the oil lifespan is extremely long, and the replacement interval is very long.
* For the replacement interval, refer to the above table.
■ Speed reduction section
Replace lubricating oil described in the above table at the specified replacement interval.
Note 1. For lubricating oil supplied at shipping, contact us accordingly.
2. The oil replacement interval differs depending on conditions of use. In particular atmospheres subject to high humidity and/or active gas, shorten the replacement interval described
in the above table.
3
3-1 Special Lubricating Oil
Lubricating oil plays an important role in power transmission, and also has various effects on burn, wear, and/or rust prevention, and/or cooling.
Since lubricating oil greatly influences the performance of the product and product life, be sure to use the special traction drive oil for the speed change
section. The type of lubricating oil differs between the speed change and speed reduction sections. In the event that different types of oil are used,
sufficient performance may not be attained, or extension of the product life may be greatly influenced.
■ The type of lubricating oil differs between the speed change and speed reduction sections. In the event that different types of oil are used, sufficient performance may not be
attained, or extension of the product life may be greatly influenced.
3-2 Replacement of lubricating oil
Installation
Speed drive
Speed drive
model
RX-60 to 3700
NRX-60 to 7500
ARX-60 to 750
SC-200E to 22000C
O-200E to 1500E
RX-5500
7500
NRX-11K
15K
RX-11K to 15K
NRX-18K to 30K
Lubrication
system
Speed change section
Gear section
Oil lubrication
Forced oil
lubrication
Oil lubrication
Type
Special traction drive oil for the speed
change section
JIS K 2219
Industrial Gear
Oil Class 2
ISO VG220
Brand
Idemitsu
RINGCONE Traction
Drive Oil TD Oil 10
RINGCONE Traction
Drive Oil TD Oil 22
Daphne Super
Gear Oil 220
ENEOS
Bonnoc TS220
Mobil
Mobilgear
600XP 220
Showa
Shell
Omala S2G
220
Cosmo
Cosmo Gear
SE 220
Replacement
interval
Every 20,000 hours,
or every 4 - 5 years
Every 5,000 hours, or every year
Reducer type
Planetary/Pinion reducer
Inscribed planetary reducer
Worm reducer
Speed drive
model
RX-60 / 90
NRX-60 / 90
ARX-60 / 90
RX-200B
NRX-200B / 400B
RX-400 to 7500
NRX-750 to 18K
ARX-400 to 750
SC-200E to 22000C
O-200E to 1500E
RX-90
NRX-90
ARX-90
RX-200B to 15K
NRX-200B to 30K
ARX-400 to 750
RX-90 to 3700
NRX-90 to 5500
ARX-90 to 750
SC-200E to 3700E
O-200E to 1500E
SC-200E to 3700E
O-200E to 1500E
Nominal
reduction ratio
G3M / G5M
G3M / G5M
G3 / G5 / G6
G11 to G71
N(G)11 to 71
C11 to 87
W10 to W30
Reducer frame
number
-
-
-
A / B
A / B / C
D to G
H to N
-
Lubrication
system
Grease
Grease
Oil
Oil
Grease
Oil
Oil
Type(Viscosity)
NLGI No.1
Grease
NLGI No.0
Grease
JIS K 2219
Industrial Gear Oil Class 2
ISO VG220
JIS K 2213
Turbine Oil Class 2
ISO VG46
NLGI No.2
Grease
JIS K 2219
Industrial Gear Oil Class 2
ISO VG100
JIS K 2219
Industrial Gear Oil
Class 2
ISO VG320
Brand
Idemitsu
Daphne
Coronex
EP No.1
Daphne Polylex
No.0
Daphne Super Gear Oil 220
Daphne Mechanic
Oil 46
-
Daphne Super Gear Oil 100
Daphne Super
Gear Oil 320
ENEOS
Epnoc
Grease AP1
Pyronoc Grease
No.0
Bonnoc TS220
FBK Oil RO46
-
Bonnoc TS100
Bonnoc TS320
Mobil
Mobilux
EP No.1
-
Mobilgear 600XP 220
DTE Oil Medium
-
Mobilgear 600XP 100
Mobilgear 600XP 320
Showa
Shell
Alvania
EP No.1
Stamina RL No.0
Omala S2G 220
Tellus S2M 46
-
Omala S2G 100
Omala S2G 320
Cosmo
Dynamax
EP No.1
-
Cosmo Gear SE 220
Cosmo Allpus 46
-
Cosmo Gear SE 100
Cosmo Gear SE 320
Kyodo
Yushi
Unilube
DL No.1
Excellite EP No.0
-
-
-
-
-
Nippeco
-
-
-
-
NDS Grease
-
-
Replacement
interval
Every 20,000 hours,
or
every 4 - 5 years
Every 5,000 hours, or every year
Every 20,000
hours, or
every 4 - 5
years
Every 5,000 hours, or every year