background image

5

Pressure range

102R
103R
102A

Rated pressure[kPa]

−100.0〜100.0

  −100〜1000

            0.0〜100.0 ※

Output voltage [V]

−1.000〜1.000
−0.100〜1.000

    0.000〜1.000

※Unit:kPa abs.

Top view

Protect cover

LOBAT

MkPa

bar

HOLD

psi

O.SET

in.mmHgAq

LIQUID TYPE

HANDY MANOMETER

COPAL ELECTRONICS

MODE

ZERO

SET  UP

HOLD

POWER

6     1

Connector

Manufacturer

JST Mfg. Co., Ltd.

Housing

ZHR-6

Contact

SZH-002T-P0.5
SZH-003T-P0.5

Wire gauge

AWG28〜26
AWG32〜28

Connector No.






Description

External power input (5V)

Analog output terminal (±1V)

GND

CAL
CAL
CAL

Analog Function

Attachment of protect cover

Open the battery cover on the back of the main body and insert the pre-wired connector according to the table shown below. After applying external power, 
press the  POWER  button to turn on the power. Be sure to use the product with the batteries removed. The mode will not switch to the analog output 
mode unless the batteries are removed.

Analog voltage as indicated will be output to the analog output terminal.
Pressure range, rated pressure and output voltage are shown to the table below.
No voltage or signal should be applied to the CAL terminal since it is for adjustment use only.
Failure to heed this warning may result in product malfunction or damage to the main body.

Please attach the protect cover to the main body from top 
side(the  side  of  pressure  port)to  the  end  completely.  Be 
careful  about  the  front  side  of  the  cover.  Strap  canʼt  be 
attached with the protect cover on the main body.

Periodical Calibration

If you would like to calibration request, please contact the sales office where you purchased.

Warranty 

The warranty period for the product shall be one year. A failure due to causes attributed to design or manufacturing defects during the period one year 
from the date of delivery shall be repaired or replaced free of charge. However, the term “warranty” herein referred to shall imply the warranty for the 
product unit only, and damages from failure of the product shall be excluded. The following shall be excluded from the warranty:
⑴ Failure or damage caused by improper use and careless operation in violation of the Operating Instructions.
⑵ Failure or damage caused by inappropriate modification, adjustment, or repair.
⑶ Failure or damage caused by acts of God, fire, or other unavoidable accidents.
⑷ Replacement of accessories (cables, etc.) and supplies that come with the product.
[Note]
Copying or reprinting the entire or part of the Operating Instructions shall be prohibited except where exceptions to copyright laws apply. Furthermore, 
descriptions stated in the Operating Instructions are subject to change without prior notice.

Summary of Contents for PG-100B Series

Page 1: ...ntionally in the air by holding the strap may result in unexpected accidents injury or product damage Be sure to use the product with its main body gripped firmly 6 Be careful not to give external shocks to the products External shocks such as hitting and dropping may cause product failure 7 Installation of attachments When installing an attachment to the pressure port the tightening torque should ...

Page 2: ... be careful not to allow the neutral detergent solution to enter the pressure port and or main body Infiltration of the neutral detergent may cause product failure 6 Caution for storage of protect cover Please store the protect cover in a cool and dark place if it is to be stored Ultraviolet rays exposure may make the quality of the cover deteriorate Please replace the protect cover with new one in...

Page 3: ...ero adjustment Hold Offset Auto power off Unit switching 0 5 F S 2digits Gases Liquids compatible with SUS316L 0 to 50 No freezing 15 to 85 RH or below No condensing 3 VDC AAA dry cell x 2 M5 female screw P 0 8 IP40 IEC standards 55 W 16 9 D 110 H Approx 100g Approx 1 000 hours 5 0 5V DC 5mA maximum External supply 1 000V 10mV Indicated value standard 102A Absolute 103R 102R 2 0 F S 2digits 1 0 F S ...

Page 4: ... function is invalid in 102A range because it is based on an absolute vacuum 3 Switching of auto power off function With the power turned off press the POWER button for one second or longer while pressing the HOLD button to set the mode to the switching mode of the auto power off function Choose the mode from four modes including P3 3 min P20 20 min PAt 20 min after the pressure reaches zero and PoF ...

Page 5: ...function or damage to the main body Please attach the protect cover to the main body from top side the side of pressure port to the end completely Be careful about the front side of the cover Strap canʼt be attached with the protect cover on the main body Periodical Calibration If you would like to calibration request please contact the sales office where you purchased Warranty The warranty period f...