2

Bundled Items

Model Number Designation

Maintenance Precautions

(1)Periodic maintenance check should be carried out.

Make sure the product operates normally before using. Unexpected event may cause product failure and affect its basic function..

(2)Do not disassemble or modify the product.

Unauthorized disassembly or modification may result in a malfunction. The product warranty does not cover failures caused by disassembly and/or 
modification of the product.

(3)The batteries used are AAA manganese dry cells or AAA alkaline dry cells.

Use of batteries other than as stated above may cause product failure.

(4)Insert the batteries to contact the correct positive and negative terminals.

Insertion  of  the  battery  in  the  wrong  direction  may  induce  rupture  or  electrolyte  leakage  of  the  battery,  resulting  in  product  failure.  When  the 
product is intended not to be used for a long period of time, remove the battery from it in order to prevent electrolyte leakage.

(5)Stains on the product should be wiped off with a soft, dry cloth.

Stains on the product should be wiped off with a cloth immersed in a neutral detergent diluted with water and squeezed well; dry with a soft cloth. At 
this time, be careful not to allow the neutral detergent solution to enter the pressure port and/or main body. Infiltration of the neutral detergent may 
cause product failure.

(6)Caution for storage of protect cover

Please store the protect cover in a cool and dark place if it is to be stored. Ultraviolet rays exposure may make the quality of the cover deteriorate. 
Please replace the protect cover with new one in case color of it changes or the visibility of the display deteriorates.

⑴Model number    :PG−100
⑵Available media :B

(Gases/Liquids compatible with SUS316L)

⑶Pressure range  :102R, 103R, and 102A.
⑷Indication unit   :Blank(kPa)
          M(MPa)
          H

(mmHg)

          W(With unit switching function)

**

⑸Inspection report :Blank(Not attached)
          X1

(Inspection report attached)

          X2

(Inspection report and calibration certificate attached)

⑹ Certificate   :Blank(Not attached)
          T(Traceability certificate attached)

* … For particular application. The application is necessary for buying this model.
** … Foreign sales. The application is necessary for buying this model.

・Attachments ※
     One-touch fitting:SSC6-M5 

 

 

 

 

 

 

1 piece

     Insert ring    :WR0640 

 

 

 

 

 

 

1 piece

・Strap   

 

 

 

 

 

 

 

 

 

1 piece

・Operating instructions(This manual) 

 

 

 

 

 

 

1 sheet

・AAA dry cell(The service life of the batteries that come with the product is not guaranteed.) 

2 cells

・Protect cover(with product) 

 

 

 

 

 

 

 

1 piece

※Refer to a maker's homepage for the details of an attachment. NIHON PISCO CO.,Ltd.: http://www.pisco.co.jp/

PG−100 B−103R−M X1 T

Summary of Contents for PG-100B Series

Page 1: ...ntionally in the air by holding the strap may result in unexpected accidents injury or product damage Be sure to use the product with its main body gripped firmly 6 Be careful not to give external shocks to the products External shocks such as hitting and dropping may cause product failure 7 Installation of attachments When installing an attachment to the pressure port the tightening torque should ...

Page 2: ... be careful not to allow the neutral detergent solution to enter the pressure port and or main body Infiltration of the neutral detergent may cause product failure 6 Caution for storage of protect cover Please store the protect cover in a cool and dark place if it is to be stored Ultraviolet rays exposure may make the quality of the cover deteriorate Please replace the protect cover with new one in...

Page 3: ...ero adjustment Hold Offset Auto power off Unit switching 0 5 F S 2digits Gases Liquids compatible with SUS316L 0 to 50 No freezing 15 to 85 RH or below No condensing 3 VDC AAA dry cell x 2 M5 female screw P 0 8 IP40 IEC standards 55 W 16 9 D 110 H Approx 100g Approx 1 000 hours 5 0 5V DC 5mA maximum External supply 1 000V 10mV Indicated value standard 102A Absolute 103R 102R 2 0 F S 2digits 1 0 F S ...

Page 4: ... function is invalid in 102A range because it is based on an absolute vacuum 3 Switching of auto power off function With the power turned off press the POWER button for one second or longer while pressing the HOLD button to set the mode to the switching mode of the auto power off function Choose the mode from four modes including P3 3 min P20 20 min PAt 20 min after the pressure reaches zero and PoF ...

Page 5: ...function or damage to the main body Please attach the protect cover to the main body from top side the side of pressure port to the end completely Be careful about the front side of the cover Strap canʼt be attached with the protect cover on the main body Periodical Calibration If you would like to calibration request please contact the sales office where you purchased Warranty The warranty period f...

Reviews: