Specifications

Name of Each Part

POWER

HOLD

 UP

SET

ZERO

MODE

COPAL ELECTRONICS

HANDY MANOMETER

LIQUID TYPE

PG-100B-103R

BATTERY:1.5V×2 LR03,R03

RANGE  :-100 〜 1000 kPa

Don't supply over range pressure.

MADE IN JAPAN

CAUTION

SERIAL :0L5001

O.SET

LOBAT

in.mmHgAq

psi

HOLD

bar

MkPa

*Only W type can switch all display unit. 

**Out-of-specification when the analog output function is used.

Model
Pressure range
Type
Rated pressure

Max. pressure
Indication system
Resolution
Indication unit
Function
Indication accuracy(at 25℃)
Indication accuracy(at 25±25℃)
Available media
Operating temp.
Operating humidity
Driving power
Pressure port
IP protection
Outer dimensions
Weight
Battery service life
Analog output(at 25℃)
Power supply
Output voltage
Output accuracy

PG-100B

3-1/2-digit LCD

1digit

kPa, MPa, mmHg, in.Hg, mmAq, psi, bar*

Zero adjustment, Hold, Offset, Auto power off, Unit switching

±0.5%F.S.±2digits

Gases/Liquids compatible with SUS316L

0℃ to 50℃(No freezing)

15 to 85% RH or below (No condensing)

3 VDC, AAA dry cell x 2

M5 female screw(P=0.8)

IP40(IEC standards)**

55(W)×16.9(D)×110(H)

Approx. 100g

Approx. 1,000 hours

5±0.5V DC, 5mA maximum, External supply

±1.000V

±10mV (Indicated value standard)

102A

Absolute

103R

102R

±2.0%F.S.±2digits

±1.0%F.S.±2digits

0〜100kPa abs.

(mmHg undisplayable)

200kPa abs.

−100〜1000kPa

(mmHg undisplayable)

1500kPa

−100〜100kPa

(−750〜750mmHg)

200kPa

Pressure range

102R
103R
102A

Unit switching function(Only for −W model)

mmHg



in.Hg



psi



bar



mmAq



MPa



kPa



“−”means undisplayable.

Gauge

AAA Dry Cell (2 cells)

・Unit indication

・Pressure indication

LCD

Pressure Port

M5×0.8

Screw depth: 5

Nameplate

ZERO Button

・Zero adjustment

・Offset/Cancellation

・Under switching mode: 

   "SELECT"
HOLD Button

・Hold/Cancellation

・Under switching mode: 

    "ENTER"

Attachment

POWER Button

・Turning power

    ON/OFF

Function Indication

・For Offset: 

   "O.SET"

・For battery low: 

   "LOBAT"

・For Hold: 

   "HOLD"

Summary of Contents for PG-100B Series

Page 1: ...ntionally in the air by holding the strap may result in unexpected accidents injury or product damage Be sure to use the product with its main body gripped firmly 6 Be careful not to give external shocks to the products External shocks such as hitting and dropping may cause product failure 7 Installation of attachments When installing an attachment to the pressure port the tightening torque should ...

Page 2: ... be careful not to allow the neutral detergent solution to enter the pressure port and or main body Infiltration of the neutral detergent may cause product failure 6 Caution for storage of protect cover Please store the protect cover in a cool and dark place if it is to be stored Ultraviolet rays exposure may make the quality of the cover deteriorate Please replace the protect cover with new one in...

Page 3: ...ero adjustment Hold Offset Auto power off Unit switching 0 5 F S 2digits Gases Liquids compatible with SUS316L 0 to 50 No freezing 15 to 85 RH or below No condensing 3 VDC AAA dry cell x 2 M5 female screw P 0 8 IP40 IEC standards 55 W 16 9 D 110 H Approx 100g Approx 1 000 hours 5 0 5V DC 5mA maximum External supply 1 000V 10mV Indicated value standard 102A Absolute 103R 102R 2 0 F S 2digits 1 0 F S ...

Page 4: ... function is invalid in 102A range because it is based on an absolute vacuum 3 Switching of auto power off function With the power turned off press the POWER button for one second or longer while pressing the HOLD button to set the mode to the switching mode of the auto power off function Choose the mode from four modes including P3 3 min P20 20 min PAt 20 min after the pressure reaches zero and PoF ...

Page 5: ...function or damage to the main body Please attach the protect cover to the main body from top side the side of pressure port to the end completely Be careful about the front side of the cover Strap canʼt be attached with the protect cover on the main body Periodical Calibration If you would like to calibration request please contact the sales office where you purchased Warranty The warranty period f...

Reviews: