This page is split into three parts in standard mode:
- Assignment of faults
- Assignment of digital outputs
- faults options
- Assignment of faults and digital outputs
The main faults can be supervised by assigning them to digital outputs.
NOTA : The fault « Unbalance current » is only selectable if 3 CT are checked.
This page offers the possibility of assigning faults and operating modes to 4 outputs (AL1, AL2,
D01 and D02).
Example of settings:
- Assignment of «Overvoltage» fault to AL1
- Assignment of «PT100-1 overtemperature» fault to AL2 with the maximum temperature set at
200°C
- Assignment of «Loss of voltage sensing» fault to DO1
- Assignment of «PF/kVAR» digital output to D02