![background image](http://html1.mh-extra.com/html/nidec/digitax-hd-m75x-series/digitax-hd-m75x-series_quick-start-manual_1687791008.webp)
8
Digitax HD M75X Quick Start Guide
Issue Number: 2
1
Product information
1.1
Ratings
Table 1-1 Drive ratings, cable sizes and fuse ratings
* These are fast acting fuses.
** Short circuit rating - Input current based on a symmetrical supply fault level of 5 kA. For UL
installations with a short circuit current rating greater than 5 kA refer to the
Digitax HD M75X Series
Installation and Technical Guide
.
1.2
Model number
Figure 1-1 Model number
Model
No of
input
phases
Typical AC
input current
(single axis)
AC Fuse ratings
(single axis)
Cable size (single axis)
Nominal
current
Peak
current
Typical
continuous
output power
Input
**
Output
A
IEC gG
UL Class
CC, J or T
*
mm
2
AWG
mm
2
AWG
A
A
kW
01200022
1
3.7
8
15
0.75
14
0.75
24
1.1
6.6
0.3
01200040
1
6.9
12
15
1.5
14
0.75
22
2.2
12
0.7
01200065
1
11.4
16
15
2.5
12
0.75
20
3.5
19.5
1.1
02200090
1
17.7
25
25
4
10
0.75
16
5.6
27
1.8
02200120
1
23
32
30
6
10
0.75
16
7.5
36
2.3
03200160
1
31.5
32
40
6
8
1.5
14
10.8
48
3.4
01200022
3
5.8
8
15
0.75
14
0.75
20
2.2
6.6
0.7
01200040
3
7.9
12
15
1.5
14
0.75
18
4
12
1.3
01200065
3
10.5
16
15
2.5
14
0.75
16
6.5
19.5
2
02200090
3
16.7
25
25
4
10
1
14
9
27
2.7
02200120
3
20.3
32
30
6
10
1.5
12
12
36
3.7
03200160
3
27.9
32
40
6
8
2.5
12
16
48
5
01400015
3
3.1
6
15
0.75
14
0.75
20
1.5
4.5
0.8
01400030
3
4.8
8
15
0.75
14
0.75
20
3
9
1.6
01400042
3
5.3
8
15
0.75
14
0.75
18
4.2
12.6
1.9
02400060
3
10.1
16
25
2.5
14
0.75
16
6
18
3.1
02400080
3
12.1
16
25
2.5
12
0.75
14
8
24
4.2
02400105
3
14.9
20
25
4
12
1.5
14
10.5
31.5
3.6
03400135
3
20.8
32
30
6
10
2.5
12
13.5
40.5
6.9
03400160
3
22
32
30
6
10
2.5
12
16
48
7.6
Identification Label
Electrical Specifications
Derivative
Frame Size:
Voltage Rating:
Current Rating:
Nominal current rating x 10
Power Format:
0
Optional Build
Customer Code
00
A
B
1
0
1
Cus tomer Code :
00 = 50 Hz
Documentation
1
Doc umentation:
2 - 200 V (200 - 240 ±10 %)
4 - 400 V (380 - 480 ±10 %)
M753 -
01 2
00022
A
Configuration
1
Safety:
1 - Standard
Enc ode r Interface:
0 - Standard
01 = 60 Hz
Power
Format
Encoder
Interface
Mounting kit and display options:
AB101 - Mounting kit not fitted/
Compact display fitted
(M750, M753)
AB110 - Mounting kit fitted/
Compact display not fitted (M751)
Digitax HD range
Pro duct Line
M751 - Base
M753 - EtherCAT
M750 - Ethernet
01
02
03