General  Notes

Please observe the following safety precautions:

1.

Fill the tank prior to connection to power supply.

2.

Connect only to a power supply with the corresponding voltage to that specified on the rating
label positioned on the rear of the unit.

3.

Ensure the power supply has a safety earth (ground) terminal.

4.

Ensure the mains switch and power supply connector are accessible during use.

5.

The mains supply cord fitted to this products is a heat resistant type and should be replaced by
an equivalent type.

6.

Do not block ventilation slots during use.

7.

Always follow good laboratory practice by ensuring substances being heated present no risk of a
hazard (explosion, implosion or release of toxic or flammable gases) or that these have been
addressed. When heating substances where liberation of gases occurs suitable extraction should
be used.

8.

Use only liquids specified in this Instruction Manual within their specified temperature range.

9.

Use caution when topping up or draining the tank as the liquid in the tank may be very hot or
cold.

10.

Drain before moving the bath. Allow the liquid to cool to 50°C or heat up to 10°C or above
before draining.

11.

Use caution when refilling as a hot heating element can create scalding steam.

12.

Always use a lid or layer of polypropylene spheres when operating at temperatures above 60°C.
Take care when lifting the lid. Steam and hot vapours can cause scalding.

13.

Always use the display or a thermometer to check the temperature - do not touch liquid.

14.

If this product is not used in accordance with these instructions, then basic safety protection
afforded by the water bath may be affected.

15.

Check the operation of the low liquid level float switch regularly.

16.

Before using any cleaning or decontamination method except those recommended, check with
your distributor that the proposed method will not damage the equipment.

Amendments

Issue 1

February

2004

New book dedicated to NE4T’s.

Issue 2

December

2004

Amendment to Service Diagram.

Issue 3

December

2005

Updated to service diagram.

Issue 4

August

2006

Update for WEE, DOC, accessories, overview, cleaning

Issue 5

November

2006

Anti-bacterial paint finish

Issue 6

May

2013

Updated with E version instructions.

Symbols

HOT SURFACES

Paragraphs marked by this symbol indicate that a potential hazard to your personal
safety exists from heated surfaces or other appendages on the outside or inside of
the equipment.

CAUTION

This icon accompanies text and/or other international symbols dealing with potential
damage to equipment. When present, it indicates that there is a potential danger of
equipment damage may occur if information stated within the "CAUTION" paragraph
is not adhered to or procedures are executed incorrectly.

The Clifton Range - 3 Year Warranty

3

High Quality  Products at Affordable Prices

PROTECTIVE EARTH OR GROUND TERMINAL

Protective earth conductor terminal.

Summary of Contents for NE4-E Series

Page 1: ...level float switch and if the liquid drops below the recommended level heating is automatically switched OFF top up liquid level then switch off and back on again using the mains switch located on th...

Page 2: ...painted surfaces with Anti bacterial finish 8 Cleaning the stainless steel tank 8 Descaling the stainless steel tank 9 Decontaminationof Equipment 9 VirucidalDisinfectant 9 Disinfectant Sterilant 9 3...

Page 3: ...olypropylene spheres when operating at temperatures above 60 C Take care when lifting the lid Steam and hot vapours can cause scalding 13 Always use the display or a thermometer to check the temperatu...

Page 4: ...rs supplied Turn the thermostirrer upside down and screw the nylon propellor hand tight onto the spindle The spindle is threaded in the opposite direction to the propellor to ensure the propellor stay...

Page 5: ...electrical supply Suitable Liquids Operating temperatures and recommended liquid options Ambient to 99 C Distilled water Heat transfer liquid The LB range is formulated for temperatures from 45 C to 9...

Page 6: ...ater bath NE4 T series stainless steel tank with false base shelf fitted inside NE4 E series clear tank with shelf fitted Indicators heating temperature alarm timer and set temperature Tank View Low l...

Page 7: ...to stabilise and take an actual reading at the far end of the bath to the Thermostirrer Where necessary adjust the temperature controller Heater indicator will illuminate Low Liquid Level Float Switc...

Page 8: ...nge is maintained over its lifetime as the anti bacterial agent is integral within the paint In a laboratory environment it makes this one less source of contamination contributing to essential clean...

Page 9: ...ment and instruments where autoclaving is neither practical nor necessary For more detailed information relat ing to how Virkon should be used with access to test reports www relyon dupont com Is Virk...

Page 10: ...lifton prod ucts are easily recycled with majority of the product constructed from stainless or mild steels which can readily be re used or recycled In excess of 78 of this product range can be easily...

Page 11: ...to suit 22 and 28 Litre Baths Stainless Steel Test Tube Racks Dimensions 270 x 70 x 138mm L x W x H 6870 Stainless Steel Test Tube Rack 26 Hole x 17mm Diameter 6871 Stainless Steel Test Tube Rack 16 H...

Page 12: ...Place the loaded test tube rack into the bath on top of either the stainless steel perforated shelf or the raised shelf Thermometer Clip This can be positioned anywhere on the perimeter of the bath b...

Page 13: ...Spares Service Diagram The Clifton Range 3 Year Warranty 13 High Quality Products at Affordable Prices...

Page 14: ...t finish and is complete with a stainless steel shelf designed for good temperature stability STIRRED Features Include Sensitivity 0 2 C Uniformity 0 05 C Temperature range ambient 5 C 99 C Thermostat...

Page 15: ...for electrical equipment for measurement control and laboratory use BS EN 61326 Electrical equipment for measurement control and laboratory use EMC requirements NICKEL ELECTRO LTD Manufacturers of lab...

Page 16: ...BX0844 BX0845 www nickel electro co uk...

Reviews: