7
– English
EN
3.6 - Settings/Adjustments
3.6.1 - SETTING THE TYPE OF “DRY-CONTACT”
01.
Press the button
DRY
CONT.
: the current setting appears on the level LEDs.
02.
Use the
or
button to turn on the LED that corresponds to the desired
setting.
03.
➔
The
green OK
LED flashes: (within 3 sec) press the
OK
button to confirm.
Note:
the number of
levels available and the
types of behaviour of
each dry-contact de-
pend on the connected
motor (refer to the motor
manual).
Level LEDs
Type of dry contact
1
DRY_1
2
DRY_2
3
DRY_3
4
DRY_4
5
DRY_5
6
DRY_6
7
DRY_7
8
DRY_8
• Deleting position “I”
01.
Press the button
AUTO
: the LED on the button flashes.
02.
Press the button
RADIO
TEST
: the LED on the button flashes.
03.
➔
The
green OK
LED flashes: (within 3 sec) press the
OK
button to confirm.
04.
Once this operation terminates, the LED on the button
AUTO
flashes.
3.6.3 - SETTING THE SPEED
01.
Press the button
RDC
: the current setting will appear on the level LEDs.
If a speed value has been set with procedure 3.6.2, the LEDs flash to indicate
the approximate closest value.
02.
Use the button
or
, until to turn on the LED that corresponds to the
desired setting.
03.
➔
The
green OK
LED flashes: (within 3 sec) press the
OK
button to confirm.
Note:
the number of
levels available depends
on the type of motor
connected and its ma-
ximum and minimum
speed values.
Examples of levels available for ERA INN
Level LEDs
Speed (RPM)
1
6
2
12
3
20
4
26
5
32
6
40
7
48
8
56
3.6.2 - SETTING THE TIME OF DURATION THE MANEUVER
Warning!
- You can set the duration of the maneuver only if limit switches “0” and “1”
have already been set.
01.
Press the button
RDC
: the current setting will appear on the level LEDs.
If the operating time is not programmed, the LED flashes to indicate the closest
approximation, obtained from the motor speed setting.
02.
Use the
or
button to turn on the LED that corresponds to the desired
setting.
03.
➔
The
green OK
LED flashes: (within 3 sec) press the
OK
button to confirm.
Note:
the number of
available levels depends
on: the type of motor
connected, its maximum
and minimum speed
values and the positions
“0” and “1” stored.
Examples of levels available for ERA INN
Level LEDs
Maneuver time [sec]
1
5
2
7
3
10
4
15
5
20
6
25
7
30
8
35
9 (A1)
40
10 (A2)
50
11 (A3)
60
12 (A4)
70
13 (A5)
80
14 (A6)
90
15 (A7)
100
16 (A8)
110