English -
13
EN
CMD 2--> addr: 3, cmd: 4
CMD 3--> addr: 5, cmd: 12
5.8
–
Command for setting the duration
of the mechanical motor movements
The duration of the mechanical motor movements can be
set. The relevant command is:
SET_TIME [XXX] [Carriage Return]
The fields are one space apart and the string ends with Car-
riage Return.
The fields are:
SET_TIME
Command for setting the duration.
[XXX]
Value in seconds (max. 240 sec.).
The default value at initial start-up is 10 seconds and any
modification of this value is stored in the memory.
At the next re-start, the last value stored will be used.
5.9
–
Changing a device’s address
The address of a motor can be set using the following com-
mand:
ADR [XX] [YY] [Carriage Return]
The fields are one space apart and the string ends with Car-
riage Return.
The fields are:
[XX]
Current address of the motor; the address must
mandatorily contain two digits and must be in
hexadecimal form.
[YY]
New address of the motor; the address must
mandatorily contain two digits and must be in
hexadecimal form.
For example, for modifying the motor address from 03 to 07,
use the following command.
ADR 03 07 [Carriage Return]
5.10
–
Viewing information on memorised
transmitters
Information on memorised transmitters can be viewed using
the following command:
TLC_STATUS [Carriage Return]
The information regards the number of memorised transmit-
ters and their operating mode.
The typical response will be:
tlc_status
Number of remote control in mem: 3
Number of free position in mem: 29
TLC 1 : Mode 2 - Function number 1 - Key UP
TLC 2 : Mode 1
TLC 3 : Mode 2 - Function number 2 - Key DOWN
Summary of Contents for TT6
Page 2: ...2 2 ...
Page 119: ......
Page 120: ...IS0064A00MM _20 09 2011 www niceforyou com Nice SpA Oderzo TV Italia info niceforyou com ...