3.5) Description of the electrical connections
Here follows a brief description of the electrical connections. Please
refer to the “7.3. Adding or Removing Devices” paragraph for further
information.
FLASH:
flashing light output “LUCYB” type or similar outputs with a
single 12V lamp, max. 21 W.
S.C.A.:
“Open Gate Light” output. An indication lamp can be con-
nected (24V max. 4W).
BLUEBUS:
compatible devices can be connected up to this termi-
nal. They are connected in parallel using two conductors only,
through which both the electricity supply and the communication
signals travel. Please refer to paragraph “7.3.1BlueBUS” for further
information about BlueBUS.
STOP:
input for the devices which block or eventually stop the
manoeuvre in progress. Contacts like “Normally Closed”, “Normally
Open” or constant resistance devices can be connected up using
special procedures on the input. Please refer to Paragraph “7.3.2
STOP Input” for further information about STOP.
P.P.:
input for devices which control movement. It is possibile to
connect “Normally Open” devices up to this input.
ANTENNA:
connection input for the radio receiver aerial (the aerial
is incorporated in LUCY B).
13
14
15
The manufacturers recommend you position the leaf at approximately half travel before starting the checking and start up phase of the
automation. This will ensure the leaf is free to move both during opening and closure.
4) Final checks and start up
4.1) Choosing the direction
The direction of the opening manoeuvre must be chosen depending
on the position of the gearmotor with respect to the leaf. If the leaf
must move left for opening, the selector must be moved towards left
as shown in Figure 16; alternatively, if the leaf has to move right
during opening, the selector must be moved towards the right as
shown in Figure 17.
16
17
LUCYB
S.C.A.
MOFB
MOSE