EN
8
– English
Note
– The factory settings are highlighted in grey.
L8
L1
L2
L3
L4
L5
L6
L7
L8
Manoeuvre 1 result (most recent)
Manoeuvre 2 result
Manoeuvre 3 result
Manoeuvre 4 result
Manoeuvre 5 result
Manoeuvre 6 result
Manoeuvre 7 result
Manoeuvre 8 result
The type of fault that has occurred in
the last 8 manoeuvres can be establi-
shed
See TABLE 12 – Fault log.
List of
faults
TABLE 8
-
Programming procedure second level functions
01.
Press and hold down the “
Set
” key for approx. 3 seconds.;
02.
Release the key when LED “
L1
” starts flashing;
03.
Press the “
” or “
u
” key to move the flashing LED to the LED representing the “input LED” of the parameter to be modified;
04.
Press and hold the “
Set
” key through to completion of point 06;
05.
Wait approx. 3 seconds, until the LED representing the current level of the parameter to be modified illuminates;
06.
Press keys “
” or “
u
” to move the LED representing the value of the parameter;
07.
Release the “
Set
” key;
08.
Wait 10 seconds (maximum time) to exit the programming mode.
Note
– During this procedure, points 03 to 07 need to be repeated when programming other parameters during the phase itself .
SET
SET
SET
SET
L1
or
or
3 s
10 s
6.3 - Special functions
6.3.1 - Function: “Move anyway”
This function allows the automation to be operated even when any of the safe-
ty devices does not work correctly or is out of use.
The automation can be controlled in the “
hold-to-run
”, mode. Proceed as fol-
lows:
01.
Send a command to operate the gate using a transmitter or a key selector,
etc. If everything operates correctly, the gate will move normally, otherwise
proceed as follows;
02.
within 3 seconds, activate the control again and keep it activated;
03.
after approximately 2 seconds, the gate will perform the required move-
ment in “
hold-to-run
”; mode; i.e. the gate will continue to move only as
long as the control is activated.
If the safety devices do not operate, the flashing light flashes a few times to indi-
cate the kind of problem (see chapter 6 - Table 10).
6.3.2 - Function: “Maintenance warning”
This function serves to indicate when automation maintenance is required. The
maintenance warning signal is emitted by a lamp connected to the “flash” or
“els” output when this output is programmed as a “maintenance indicator light”
The various light signals are shown in
Table 9
.
To program the limit value of the maintenance operations, see
Table 7
.
6.4 - Deleting the memory
To delete the control unit memory and restore all factory settings, proceed as
follows:
press and hold keys “
” and “
u
” until leds L1 and L2 start flashing.
TABLE 9 - “Maintenance light”
Number of manoeuvres
Signal
Below 80% of the limit
Between 81% and 100% of the limit
Beyond 100% of the limit
Light on for 2 seconds at the start of the opening manoeuvre.
Light flashing for the entire duration of the manoeuvre.
Light flashing continuously.
Summary of Contents for POP PP7124
Page 2: ......
Page 109: ...IX 1 2 3 3a 315 mm max 250 mm 167 mm 545 mm min 400 mm 254 mm...
Page 110: ...X 4 6 5 7 M8x55 M6x100 8 1 2 A MAX B...
Page 111: ...XI 9 1 2 10 1 2 M6x20...
Page 112: ...XII A 11 12 PP7224 PP7124...
Page 113: ...XIII N L 13 PP Sto p Blueb us Flash PP7224 ELS Open 15 14...
Page 114: ...XIV 16 1 2 17 18...
Page 115: ...XV 1 2 19 20 4 5 7 3 6 2 1...
Page 116: ...IS0095A01MM_04 02 2013 www niceforyou com Nice SpA Oderzo TV Italia info niceforyou com...