To set the Operation Mode set the PROG switch to the position as
shown in the figure below, and press the LEARN button according to
the desired setting:
PROG SWITCH POSITION
PROGRAMMING
OPERATION MODE
LED BLINKS
1 time
2 times
3 times
APFP
AF
APF
27 - PHOTOCELL SETTINGS
In this mode it is possible to configure the photocell operation mode:
NA: Normal operation (Normally Open);
Photocell Closes: In this mode, after leaving the front of the photocell
the gate closes automatically after counting the set time.
Count Queue: In this mode, upon receiving a pulse from (Pushbutton
Opens), the switch adds 1 to the counter, and will only close the gate
after passing in front of the photocell.
Example: If 3 pulses are received at the pushbutton (Opens), it will
be necessary to perform 3 triggers on the photocell to close the gate.
To configure photocell operation, set the PROG switch to the position
as shown in the figure below, and press the LEARN button according
to the desired setting:
82