4
– English
English
3.1 - INSTALLING THE LIMIT SWITCHES
01.
Position, approximately, the two limit switch brackets [A] on the rack
(Fig. 12).
02.
Move the gate by hand to the open position, stopping it at least 2–3
cm before the mechanical stop; while moving the gate, make sure
that the rack slides smoothly on the pinion.
03.
Slide the limit switch bracket along the rack in the opening direction
until the limit switch trips. Next, move the bracket at least 2 cm further
and then lock it onto the rack with the grub screws provided.
04.
Repeat the same operation to fasten the closed position limit switch.
A
248
216
33
90
305
12
3.4 - ELECTRICAL CONNECTIONS
Make the electrical connections for the various elements according to the following diagram (Fig. 13).
The connections must be made in no-voltage conditions.
NC
TX
RX
NO
Fuse 1A
T
Flas
h
ECSbus
Sto
p
Aerial
Sb
S
OG
I
Fuse 15A
L4
L3
L2
Sb
S
L1
led Stop
led SbS
led ECS
(B)
(A)
(C)
230 V, 500 W max
(D)
A
LM100 (optional)
B
Additional safety element. There’s no use connecting it if it will not be used.
C
Contact for connecting an intercom or video intercom only if these devices have a “dry” contact output.
D
Lamp connection (Not present in version AU01).
13
Summary of Contents for FILO 400
Page 34: ...Français English ...
Page 35: ...Italiano Polski ...