![Nice AVIO1000 Instructions And Warnings For Installation And Use Download Page 52](http://html1.mh-extra.com/html/nice/avio1000/avio1000_instructions-and-warnings-for-installation-and-use_1686800052.webp)
24
– English
English
TECHNICAL CHARACTERISTICS OF THE VARIOUS COMPONENTS OF THE PRODUCT
The product AVIO600 / AVIO1000 is produced by Nice S.p.a. (TV) I. In order to improve its products, Nice S.p.a. reserves the right to modify their tech-
nical characteristics at any time without prior notice. In any case, the manufacturer guarantees their functionality and fitness for the intended purposes.
Note: all the technical characteristics refer to a temperature of 20°C.
DESCRIPTION
DATA
AVIO600
AVIO1000
Type
Electromechanical gearmotor for automated sectional and overhead doors incorporating a control
unit complete with radio receiver for “ECCO5...” transmitters.
Adopted technology
24V
motor, helical teeth reduction gear; drive guide with timing belt and mechanical release. A
transformer inside the motor but separated from the control unit reduces mains voltage to the nomi-
nal voltage of 24V
used by the automation system.
Peak thrust [corresponds to the force
necessary to move a leaf]
10,8 Nm
[600 N]
18 Nm
[1000 N]
Nominal torque [corresponds to the
force necessary to keep a leaf moving]
5,4 Nm
[300 N]
9 Nm
[500 N]
Idling speed
0,2 m/s
0,2 m/s
Speed at nominal torque
0,09 m/s
0,09 m/s
Maximum frequency of cycles
50 complete cycles per day
Maximum continuous cycle time
(For a maximum of approx. 10 cycles per hour. A maximum of 5 cycles per hour
is permitted at 50°C
Operating Limits
Its structural characteristics make it suitable for use on sectional and overhead doors with counter-
weights that are within the dimensions and limits indicated in table 7
Power supply AVIO
230 V
(±10%) 50/60 Hz
Max. absorbed power
250 W
370 W
Insulation class
I (a safety grounding system is required)
Emergency power supply
with PR100 accessory
Flashing light output
For Led visual signalling devices (mod. FL200)
Courtesy light
Internal LED light
BUS output
One output with a maximum load of 6 ECSbus units
“OPEN” input
For normally open contacts (the closing of the contact causes the “OPEN” command)
“SbS” input
For normally open contacts (the closing of the contact causes the “Step-by-Step” command)
“STOP” input
For normally open contacts and/or for 8,2kΩ constant resistance, or normally closed contacts with
recognition of the “normal” status (any variation from the memorised status causes the “STOP”
command)
Radio aerial input
52 Ω for RG58 or similar type of cable
Maximum cable length
Mains power supply: 30 m; inputs/outputs: 20m with aerial cable preferably shorter than 5m
(observe the directions regarding the minimum gauge and type of cable)
Remote control possibility
With ECCO5... transmitters, the control unit can receive one or more of the following commands:
“Step-by-Step” (SbS), “Partial opening”, “Open only” and “Close only”
ECCO5... transmitters memorised
Up to 100 if memorised in mode 1
Range of ECCO5... transmitters
From 10 to 50 m without aerial, from 50 to 100 m with aerial incorporated in the FL200 flashing
light. The range can vary if there are obstacles or electromagnetic disturbances, and is affected by
the position of the receiving aerial incorporated in the flashing light.
Programmable functions
Pause time: selectable options 10, 20, 40, 80 seconds
Motor speed: 4 configurations available
Motor force: 4 configurations available
“Step-by-Step” (SbS) command: 4 configurations available
Exclusion position: 4 possible configurations
Self-programmed functions
Automatic detection of devices connected to the BUS Output.
Automatic detection of the type of “STOP” device (NO/NC contact, 8.2 kΩ resistor or OSE optical device)
Automatic detection of door length and calculation of deceleration points.
Operating ambient temperature
-20°C...+55°C
Assembly
Horizontal
Protection rating
IP40
Dimensions / weight
380 x 280 x h 110 mm / 4 kg