BATTERY CONNECTIONS
If an electrical battery charger will be used, a 12 volt
sealed lead acid battery rated for 33 or 34 ampere hour
or more is recommended.
A 1.5 amp automatic battery charger is sufficient for
most applications
The battery may also be recharged with a solar panel. If
solar charging is a requirement refer to page 4 or contact
our customer service department at 800-226-0178 to
help determine the solar panel size needed. A 12 volt
105 ampere hour battery is recommended with solar
charging.
BAT12V33
12 Volt 33 to 34aH Sealed Battery
Connect the two ring terminals on the connec-
tor end of the cable to the battery. The battery
charger or solar panel should be installed at
this time.
(RED is po) and Black is negative(-)
This is pre-installed on in
the control box.
The operator is now active. Limits must be set and tested. The current sense must now be pro-
grammed as shown on page 15.
If the operator does not work, check the battery connections for proper polarity. If the connections
are reversed, the “
REVERSE BATTERY POLARITY
” LED will be illuminated at the bottom center of
the circuit board.