13
13
Step 10:
Set Limit Switches
Press LED Enable on the right
side of the circuit board.
Turn program switch #1 off
(
TIMER TO CLOSE
)
The gate should be in the closed position. Rotate the bottom collar until the
closed
LED illu-
minates. Open the gate to the desired open position and stop the gate. Rotate the top mag-
net collar until the
open
limit LED illuminates.
Step 11: Re-install Cover and re-engage manual release
Hint: To test wiring of motor do the following
1.
Put gate 1/2 way closed and plug main harness into emergency bypass for 2 seconds. Gate should OPEN. If gate
closes, reverse the red and black motor wires and re-test.
2.
Turn on LEDs on board and put gate in open position; the open LED should light. Put gate in the closed position; the
closed LED light should light. If the opposite light lights reverse the orange and white wires.