Filler valve (QM10)
NOTE
The non-return valve in the filler valve (QM10)
in F750 must be removed to prevent vacuum
in AHPS.
1. Remove the non-return valve located next to the
filler valve (QM10).
2. Install enclosed R15 plug
F750, Copper
LEK
/
A
PH
Plug
LEK
/
A
PH
F750, Stainless steel
LEK
/
A
PH
Plug
LEK
/
A
PH
Immersion heater connection
1. Install 2 enclosed o-rings Ø28mm in the grooves
on the connector on the other flexible hose.
O-rings
Flexible pipe
2. Install the flexible pipe in the immersion heater
connection with the supplied metal clip (28 mm).
Flexible pipe
Metal clip
Immersion heater
connection
3. Route the flexible pipe to the rear of F750.