INSTALLATION AREA
The distance between S2125 and the house wall must be at least 350 mm, but not more than 500 mm in locations that are
exposed to the wind. The free space above S2125 must be at least 1,000 mm. The free space in front must be at least
1,000 mm for any future servicing.
350 mm
Fritt utrymme bakom
Fritt utrymme framför
dock 1000 mm för ev. framtida service
Min. avstånd
vid användning
av flera F2300
600 mm
1000 mm
400 mm
Minimalt
fritt utrymme
600mm
Minimalt
fritt utrymme
Minimum free
space
Minimum free space
Minimum distance during use
of several S2125
600 mm
600 mm
400 mm
Free space in front for any future servicing
350 – 500 mm
Free space behind*
At least 1,000
mm
* The space behind must not exceed 500 mm in locations that are exposed to the wind.
9
Chapter 2 | Delivery and handling
NIBE S2125