Sound levels
2 m
6 m
10 m
LEK
2 m
6 m
10 m
S2125 is usually placed next to a house wall, which gives a
directed sound distribution that has to be taken into consid-
eration. Accordingly, when setting up, you should always
attempt to select the side that faces the least sound-sens-
itive neighbouring area.
The sound pressure levels are further affected by walls,
bricks, differences in ground level, etc and should therefore
only be seen as guide values.
Sound pressure at distance (m)
2
Sound
power
1
10
9
8
7
6
5
4
3
2
1
24
25
26
27
28.5
30
32
34.5
38
44
49
Nominal sound value
S2125-8
30
31
32
33
34.5
36
38
40.5
44
50
55
Max. sound value
25
26
27
28
29.5
31
33
35.5
39
45
50
Max. sound value, silent
mode
24
25
26
27
28.5
30
32
34.5
38
44
49
Nominal sound value
S2125-12
34
35
36
37
38.5
40
42
44.5
48
54
59
Max. sound value
29
30
31
32
33.5
35
37
39.5
43
49
54
Max. sound value, silent
mode
1
Sound power level, L
W
(A), according to EN12102
2
Sound pressure calculated according to directivity factor Q=4