Alarm list
May be due to
Description existing alarm
Alarm text on the display
Alarms
S-series
Alarms
VVM/SMO
(S2125)
Poor flow.
5 repeated alarms for low low-pressure
within 4 hours.
Low lp cooling
212
156 (80)
Significant wind effect.
Fan blocked or not connected.
5 unsuccessful start attempt.
Fan alarm from heat pump
233
224 (182)
Connection, supply line return line
switched around,
Return is hotter than flow.
Exchange Sensors
flow / return
234
225 (8)
Open-circuit or short-circuit on
sensor input.
Sensor fault BT3.
Sensor fault BT12.
Sensor fault from heat pump
530
531
227 (34)
227 (36)
Sensor fault BT14.
532
227 (38)
Sensor fault BT15.
533
227 (40)
Sensor fault BT16.
534
227 (42)
Sensor fault BT17.
535
227 (44)
Sensor fault BT28.
536
227 (46)
Sensor fault BP8.
538
227 (50)
Sensor fault BP9.
539
227 (52)
Sensor fault BT84.
541
227 (56)
System temperature and/or flow
too low.
10 failed consecutive defrostings.
Unsuccessful defrosting
236
228 (2)
Insufficient available system
volume.
Significant wind effect.
Poor flow, poor heat transfer.
Operation is stopped from the indoor sec-
tion after less than 5 minutes.
Short run times for com-
pressor
237
229 (4)
Incorrect settings for heating
and/or hot water.
Disruption in the refrigerant cir-
cuit.
3 repeated alarms for high discharge
within 4 hours.
Hot gas alarm
238
230 (78)
Lack of refrigerant.
Lack of refrigerant.
5 repeated alarms for low evaporation
temperature within 4 hours.
Low evaporation temp
240
232 (76)
Blocked expansion valve.
Significant wind effect.
Poor connection between PCB
and inverter.
Alarm 203 from heat pump for 20
seconds.
Communication fault to In-
verter
254
264 (203)
Inverter unpowered or broken.
Defective inverter. Discharge
sensor (BT14) has come loose
from its mount.
The inverter has tried to heat up the
compressor, but has failed.
Fault in inverter. Heating not
working.
494
298 (92)
The discharge sensor, BT14, or
high pressure sensor, BP9, has
come loose and is not giving cor-
rect measurement values.
Sensor BT14 or BP9 has come loose or is
otherwise defective.
Sensor BT14 or BP9 loose or
defective
495
300 (94)
Poor airflow, e.g. because of
leaves, snow or ice.
10 repeated defrostings according to the
protection conditions.
Recurring
safety defr.
291
341 (6)
Lack of refrigerant.
Lack of refrigerant.
5 repeated low pressure alarm within 4
hours.
Recurring low pressure
294
344 (72)
Blocked expansion valve.
Disruption in the refrigerant cir-
cuit.
Clogged particle filter, air or stop-
page in the heating medium flow.
5 repeated high pressure alarm within 4
hours.
Recurring high pressure
295
346 (74)
Poor system pressure.
The inverter is not compatible
Initiation fault, inverter.
Unspecified faults
314
400 (207)
The inverter is not compatible
400 (209)
Configuration file missing.
400 (211)
Charge error configuration.
400 (213)
NIBE S2125
Chapter 9 | Disturbances in comfort
40