General
S2125 is equipped with an internal electronic controller that
handles all functions necessary for operation of the heat
pump, e. g. defrosting, stop at max/min temperature, con-
nection of the compressor heater, and protective functions
during operation.
The integrated control shows information via status-LEDs
and can be used during servicing.
Under normal operating conditions the home owner does
not need to have access to the controller.
S2125 communicates with the NIBE indoor module/control
module, which means that all settings and measurement
values from S2125 are adjusted and read off on the indoor
module/control module.
Caution
The main product’s software must be the latest
version.
LED status
The base board (AA2) has a status LED for easy control and
troubleshooting.
Explanation
State
LED
Base board without power
Not lit
PWR
(green)
Base board power on
Continuous
light
CPU without power
Not lit
CPU
CPU running
Flashes
(green)
CPU not running correctly
Continuous
light
No communication with indoor
module/control module
Not lit
EXT COM
(green)
Communication with indoor
module/control module
Flashes
No communication with inverter
Not lit
INT COM
(green)
Communication with inverter
Flashes
Neither defrosting nor protection
is active
Not lit
DEFROST
(green)
Some protection is active
Flashes
Defrosting in progress
Continuous
light
No errors
Not lit
ERROR
(red)
Info alarm (temporary), active
Flashes
Continuous alarm, active
Continuous
light
Relay in de-energised position
Not lit
K1, K2, K3, K4,
K5
Relay activated
Continuous
light
No function
N-RELAY
No function
COMPR. ON
Explanation
State
LED
Inverter without power
Not lit
PWR-INV
(green)
Inverter has power
Continuous
light
HARMONIC FILTER (RA1)
Harmonic filter (RA1) has a status LED for easy control and
troubleshooting.
When the capacitor is in operation, LED 201 is lit with a
steady light.
Explanation
State
LED
Capacitor disconnected
Not lit
LED 201
(red)
Capacitor connected
Continuous
light
Master control
To control S2125, a NIBE indoor module/control module is
required, which calls upon S2125 according to demand. All
settings for S2125 are made via the indoor module/control
module. It also shows the status and sensor values from
S2125.
Parameter
space
Value
Description
4 – 14
4
°C
Cut-out value activation passive
defrosting
-5 – 5
-3
°C
Start temperature BT16 to calcu-
late index
Yes / No
No
(1 / 0)
Permit fan de-icing
Yes / No
No
(1 / 0)
Permit silent mode
Yes / No
No
(1 / 0)
Permit defrost more often
NIBE S2125
Chapter 7 | Control
32
Control