Docking
11
For the Installer
FIGHTER 2010
FIGHTER 2010
EVC 13
AV
RV
SF
SÄV
TV
FG
RG
RT 10
FIGHTER 2010 docked with EVC 13 (floating condensing)
FIGHTER 2010 is controlled by a room thermostat and
works with floating condensing against the return from the
heating system. FIGHTER 2010 works in stage 1 or stage
2 depending on the outdoor air temperature. If FIGHTER
2010 can not provide the heating requirement additional
heat is connected using the existing control equipment
from EVC 13.
Additional heat can be blocked above the set outdoor tem-
perature by means of the automatic control system in
FIGHTER 2010. The heating medium also circulates
through FIGHTER 2010 during the set stop temperature.
Hot water production only takes place using the existing
hot water heater.
The right curve is chosen on EVC 13 so that FIGHTER
2010 is not disturbed.
The accessory RT 10 is required for this option.