GB
11
PRODUCT
Type
Wood burning insert
Trade name
Contura i2
Intended area of use
Heating of rooms in residential buildings
Fuel
Wood
MANUFACTURER
Name
NIBE AB / Contura
Address
Box 134, Skulptörvägen 10
SE-285 23 Markaryd, Sweden
VERIFICATION
According to AVCP
System 3
European standard
EN 13229:2001 / A2:2004 / AC:2007
Test institute
KIWA UK 61354, NB 0692
Declaration of performance according
to Regulation (EU) 305/2011
DECLARED PERFORMANCE
ESSENTIAL CHARACTERISTICS
PERFORMANCE
HARMONISED TECHNICAL
SPECIFICATION
Fire safety
Pass
Fire classification
A1
Minimum distance to flammable
materials
Rear:
200 mm
Side:
250 mm
Ceiling: 1200 mm
Ceiling: 700 mm (front grate)
Front: 1400 mm
Floor: 275 mm
Fire hazard due to burning fuel falling out
Pass
EN 13229:2001 / A2:2004 / AC:2007
Cleanability
Pass
Emissions from combustion
CO:
< 1500
mg/ Nm
3
(13% O
2
)
Surface temperatures
Pass
Temperature on the handle
Pass
Mechanical resistance
Pass
Temperature in the space for wood storage
NPD
Nominal output
5,0 kW
Efficiency
80,3%
Flue gas temperature at nominal output
269°C
Flue gas temperature in flue spigot
NPD
The undersigned is responsible for the manufacture and conformity with the declared performance.
Niklas Gunnarsson,
Business area manager NIBE STOVES
Markaryd, April 4, 2022
No. Ci2-CPR-220404
Summary of Contents for Contura Ci2
Page 1: ...Ci2 Ci2G contura eu ...
Page 12: ...33 1 2 3 5 6 7 4 Handle with care ...
Page 14: ...35 8 9 10 ...
Page 15: ...36 11 12 ...
Page 17: ...38 Accessory Tilbehør Accessoire Tillbehör GB NO FR SE 1 2 3 ...
Page 19: ...40 3 4 ...
Page 20: ...41 x4 5 x4 6 ...
Page 21: ...42 7 mm 7 8 ...
Page 22: ...43 9 10 ...
Page 23: ...44 11 12 ...
Page 25: ......
Page 26: ......
Page 27: ......
Page 28: ...811483 IAV SE EX Ci2 2 2022 05 24 NIBE AB Box 134 285 23 Markaryd Sweden contura eu ...