Facts

!

Contura reserves the right to change dimensions and procedures specified in these instructions 
at any time without notice. Access the latest version at www.contura.eu  

Nominal output 

5 kW

Efficiency  

80,3%

Meets requirements of:

European standard EN-13229
Clean Air Act. (UK)
NS 3059 (NO)

Installation by authorised 
technician 

This manual contains instructions about how 
the insert must be assembled and installed. To 
ensure the function and safety of the insert, 
the installation should be carried out by a Hetas 
trained engineer. Contact one of our dealers who 
can recommend suitable installer. When completed, 
the installer should inform the local Council/
authority about the new installation.  

Building application

These main instructions may give guidance which 
would contravene national building regulations. 
Please refer to supplementary instructions or ask 
your local authority for advice regarding building 
regulations.
Before installing a stove or erecting a chimney it 
is necessary for you to make a building application 
permission to your local authority.
The owner of the house is personally responsible 
for ensuring compliance with the mandatory safety 
requirements and must have the installation 
approved by a qualified inspector. Your local 
chimney sweep must also be informed about the 
installation as this will affect the routines for 
regular chimney-sweeping services.

Structural support

Check that the wood joists are strong enough to 
bear the weight of the stove and chimney. The 
stove and chimney can usually be placed on a 
normal wooden joist in a single occupancy house if 
the total weight does not exceed
400 kg.

Hearth plate

Due to the risk of falling embers, a flammable 
floor must be protected by a hearth plate. It must 
extend 300 mm in front of the stove and 100 
mm on each side of the stove, or have a 200 mm 
extension on each side of the opening. The hearth 
plate can consist of natural stone, concrete, metal 
plate or glass. A glass hearth plate is available as 
an accessory for these models.

Final inspection of the 
installation

It is extremely important that the installation 
is inspected by an authorised chimney sweep 
before the stove is used. Also read the ”Lighting 
instructions”, before lighting for the first time. 

The insert becomes very hot

During operation, certain surfaces of the 
insert become very hot and can cause 
burn injury if touched. Be aware of the 
strong heat radiated through the hatch 
glass. Placing flammable material closer 
than the safe distance indicated may 
cause a fire. Pyre lighting can cause quick 
gas ignition with the risk of damage to 
property and personal injury. 

Connection to chimney

•  The insert must be connected to a chimney designed to withstand flue gas 

temperatures of up to 400°C.

•  The stove should not be installed in a chimney serving more than one 

appliance.

•  The diameter of the connection sleeve is designed to fit chimney pipes 

with an external diameter of Ø125 mm. A connection sleeve is available, 
as an optional extra, for chimney pipes with an internal diameter of Ø150 
mm. 

•  Normal chimney draw under nominal operation should be between 20-25 

Pa close to the connector. The draft is affected both by the length and 
area of the chimney, and by how well sealed it is. Minimum recommended 
chimney length is 3.5 m and suitable cross section area is 120-175 cm² 
(125-150 mm in diameter). 

•  A flue with sharp bends and horizontal routing reduces the draught in 

the chimney. Maximum horizontal flue is 1 m, on the condition that the 
vertical flue length is at least 5 m. 

•  It must be possible to sweep the full length of the flue and the soot 

hatches must be easily accessible.

•  Carefully check that the chimney is sealed and that there is no leakage 

around soot hatches and flue connections.

Supply of combustion air

When an insert is installed, the need for an adequate supply of air to the 
room increases. Air can be provided indirectly via a vent in the outer wall or 
via a duct from the outside that connects to the sleeve on the underside of 
the insert. The required volume of combustion air is about 20 m

3

/hour.

The connector (accessory) for the combustion air has an external diameter 
of 80 mm. When duct routing further than 1 m the pipe diameter must 
be increased to 100 mm and a correspondingly larger wall vent must be 
selected. 

In hot areas, the duct should be insulated with 30 mm mineral wool with a 
moisture inhibiting outer cover. It is also important to seal around the hole 
in the wall (or floor) of the lead-in using sealant.

A 1 m length of condensation insulated ducting for combustion air is 
available as an accessory.

Summary of Contents for Contura Ci2

Page 1: ...Ci2 Ci2G contura eu ...

Page 2: ...30 Montage 32 Fakta 3 Prestandadeklaration 4 EU försäkran om överrensstämmelse 5 Måttskiss 6 Inbyggnadsexempel 8 Montering 32 Fakta 18 Ytelseserklæring 19 EU samsvarserklæring 20 Målskisse 21 Innbyggingseksempel 23 Montering 32 Facts 10 Declaration of performance 11 EU Declaration of Confirmit 12 Dimensions diagram 13 Recess example 15 Assembly 32 ...

Page 3: ...ed Also read the Lighting instructions before lighting for the first time The insert becomes very hot During operation certain surfaces of the insert become very hot and can cause burn injury if touched Be aware of the strong heat radiated through the hatch glass Placing flammable material closer than the safe distance indicated may cause a fire Pyre lighting can cause quick gas ignition with the ...

Page 4: ...assification A1 Minimum distance to flammable materials Rear 200 mm Side 250 mm Ceiling 1200 mm Ceiling 700 mm front grate Front 1400 mm Floor 275 mm Fire hazard due to burning fuel falling out Pass EN 13229 2001 A2 2004 AC 2007 Cleanability Pass Emissions from combustion CO 1500 mg Nm3 13 O2 Surface temperatures Pass Temperature on the handle Pass Mechanical resistance Pass Temperature in the spa...

Page 5: ...ture control No In standby mode elSB kW With mechanic thermostat room temperature control No With electronic room temperature control No With electronic room temperature control plus day timer No With electronic room temperature control plus week timer No OTHER CONTROL OPTIONS Room temperature control with presence detection No Room temperature control with open window detection No With distance c...

Page 6: ...ements must be at least 1 4 metre from the front of the insert door When connecting to a steel chimney the requirements for safe distance to the chimney must also be observed A clearance of at least 300 mm must be allowed as a safe distance between an uninsulated flue pipe and com bustible building elements Dimensions diagram 3 sided frame 4 sided frame ...

Page 7: ...nce must stand on a constructional hearth which meet the building regulations and has minimum dimension as shown in the diagram Always check that the building has enough bearing capacity for the heart stove and chimney The stove can be loaded with maximum 100 kg of chimney ...

Page 8: ...t to the ceiling The recess must be sealed off above the convection exhaust The seal must be 100 mm above the convection exhaust s upper edge and must be made of 40 mm non flammable material according to the material requirements above Use heat resistant silicone for example between the seal and chimney Convection air The convection air ventilates the surround cools the insert and carries hot air ...

Page 9: ...t be a 20 mm air space between the building board and the combustible wall The air space must allow air to flow freely along the lower and upper edges see diagram to the right Diagram of aerated wall Two calcium silicate board battens ensure that the air space is maintained Firewall approved and fully complies with safety requirements according to the authorised inspection body Examples of approve...

Page 10: ...Air gap 550 40 30 275 1100 100 Area in min 300 cm2 Load bearing base Area out min 200 cm2 Combustible wall 700 min 100 20 40 40 55 100 275 1100 Area out min 200 cm2 Area in min 300 cm2 Heat shield Load bearing base 20 mm Air gap max 100 Ci2 Recess example Always observe the safety distances to combustible material required by a steel flue The dimensions are the minimum dimensions unless otherwise ...

Page 11: ...port 2 Fire bricks Vermiculite 3 Type plate 4 Grate 5 Ash pan 6 Hearth base 7 Serial number Før montering Montage Hvis innsatsen må legges ned for å flyttes bør løse deler demonteres Demontering av brennplater og hvelv er beskrevet på neste side 1 Stussplate 2 Brennplater og hvelv Vermikulitt 3 Typeskilt 4 Rist 5 Askeskuff 6 Ildstedsbunn 7 Serienummer Les éléments non fixés devront être déposés si...

Page 12: ...33 1 2 3 5 6 7 4 Handle with care ...

Page 13: ...eas This when burning wood logs and operated in accordance with these instructions and when fitted with a permanent stop to prevent closure of the air control unit beyond 31 open position Mandatory for smoke control areas The permanent stop must be installed if the appliance is to be used in a smoke control area this stop must not be removed in smoke control areas otherwise an offence will be comm...

Page 14: ...35 8 9 10 ...

Page 15: ...36 11 12 ...

Page 16: ...ara minst 10 mm luftspalt detta pga insatsens värmeutvidgning The insert is designed to be installed as a stove cassette in existing approved open hearths There must be an 10 mm air gap around the insert to allow for the expansion of the insert when hot L insert peut être installé comme une cassette dans un foyer ouvert existant et homologué Un espace d au moins 10 mm doit être prévu autour de l i...

Page 17: ...38 Accessory Tilbehør Accessoire Tillbehör GB NO FR SE 1 2 3 ...

Page 18: ...nnsatsen kan også kobles til med faste rør som føres opp i skorsteinen Raccordement à une cheminée de maçonnerie existante Pour simplifier le montage il est recommandé d utiliser un tuyau flexible proposé en option Fixez le manchon dans le tuyau Raccordez et scellez entre le tuyau et la cheminé selon les instructions séparées L insert peut également être raccordé avec des conduits fixes dans la ch...

Page 19: ...40 3 4 ...

Page 20: ...41 x4 5 x4 6 ...

Page 21: ...42 7 mm 7 8 ...

Page 22: ...43 9 10 ...

Page 23: ...44 11 12 ...

Page 24: ... de invändiga delarna i omvänd ordning Reinstall the internal components in reverse order Sett de innvendige delene tilbake på plass i motsatt rekkefølge Remontez les éléments intérieurs dans l ordre inverse SE GB NO FR ...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...811483 IAV SE EX Ci2 2 2022 05 24 NIBE AB Box 134 285 23 Markaryd Sweden contura eu ...

Reviews: