background image

14

BA-ST 9022-9100-FE

Chapter 6 |

Chapter 7 |

Chapter 8 |

Accessories and spare parts

Service

Recycling and disposal

Report any malfunctions in the buff er tank operation 

to the authorized service centres. 

7 Service

The storage tank may only be repaired/servi-

ced by an authorized service since improper 

repair can cause safety risks, and the loss of 

product warranty.

CAUTION

In order to prevent damage to piping systems 

and environmental pollution, the product sho-

uld only be disassembled and taken out of 

service by appropriately qualifi ed specialists.

CAUTION

At end-of-life, take care that the product and 

all the equipment were disposed of in accor-

dance with applicable regulations.

CAUTION

8 Recycling and 

 disposal

According  to  the  NIBE-BIAWAR  rules,  the  products 

have been manufactured of high quality materials us-

ing the latest technologies and solutions that do not 

endanger the environment.

When selecting materials, we took into account both 

the  possibility  of  reuse  of  materials  (recycling)  that 

can be disassembled and separated from materials 

unsuitable for recycling, as well as risks arising from 

the processing of materials not intended to reuse.

The purchased device consists in more than 90 % of 

parts that can be recycled and reused, so they are 

safe for the environment and human health.

The packaging, in which the product is de-

livered, is made mainly of materials suitable 

for recycling and utilization. After installa-

tion, you should ensure the proper disposal 

of packaging in accordance with applicable 

regulations.

INFORMATION

Storage tank 

model

Inspection 

opening dia.

Type of 

gasket

BA-ST 9022-FE

BA-ST 9030-FE

BA-ST 9040-FE

BA-ST 9050-FE

ø 120

Flanged 

gasket 

ø 150

BA-ST 9075-FE

BA-ST 9100-FE

ø 180

Flanged 

gasket 

ø 180

Type

Application

Mounting kit for electric heating 

module - 

1½” female

BA-ST 

9022-9050-FE

Mounting kit for electric heating 

module - 

2” female

BA-ST 

9075-9100-FE

Fig. 16. 

Mounting  kit  for  electric  heating  module  –        

– fl anged cover with 1 ½” or 2” sleeve.

Table 5. 

Mounting kit for electric heating module

Table 4. 

Inspection opening gaskets

Summary of Contents for BA-ST 9022 - FE

Page 1: ...17 01 2020 25619 Installation Operating Manual BA ST 9022 FE BA ST 9030 FE BA ST 9040 FE BA ST 9050 FE BA ST 9075 FE BA ST 9100 FE Hot Water Storage Tank ...

Page 2: ...r use by persons with reduced physical fitness mental efficiency or with out sufficient experience and knowledge if they are not supervised or instructed by a person responsible for their safety Operation of the product by children is strictly prohibited We reserve the right to make the product design changes and changes in the manual NIBE BIAWAR 2019 ...

Page 3: ..._____________________ 10 Start Up________________________ 10 Thermal Insulation of the System ____ 10 Warnings and Practical Requirements___________________ 10 5 Maintenance __________________ 11 Inspection of the Protective Magnesium Anode_______________ 11 Measurement of the Protective Magnesium Anode Wear___________ 11 Replacement of the Protective Magnesium Anode_______________ 12 Cleaning of ...

Page 4: ...the advices contained in this Manual The heated water can be supplied to several intake points at various mutually distant locations such as a bathtub wash basin sink etc 1 General Introduction Intended Use Sections of the Manual relating to the instal lation inspection and maintenance are in tended for the qualified installer CAUTION The manufacturer shall not be held liable for any damages cause...

Page 5: ... excellent thermal insulation properties of all devices Storage tanks have aesthet ic plastic housing a temperature indicator inspection opening and connectors for mounting electric heating unit and connecting the hot water circulation FR1 Protective magnesium anode UL1 Adjustable foot XL54 Thermometer XL35 Connector pipe for mounting electric heating unit QQ1 Inspection opening XL4 Hot water inta...

Page 6: ...ng XL4 Hot water intake connector pipe XL8 Hot water inlet connector pipe XL5 Hot water circulation connector pipe UL1 3 Temperature sensor cover XL9 Cold water inlet connector pipe XL3 Cold water supply connector pipe Fig 4 Section of the BA ST 9075 9100 FE storage tanks Fig 5 Side view of the BA ST 9075 9100 FE storage tanks UL1 QQ1 XL35 XL3 XL9 UA3 UA2 XL5 UA1 XL8 XL4 FR1 XL54 ...

Page 7: ...ing element connector pipe and blanking plate of the inspection opening 2 Remove the upper cover of the housing together with thermal insulation 3 Remove the plugs from the connector pipes and black bushings 4 Remove the fixing screws and the strip connect ing the housing jacket 5 Remove the jacket surrounding the tank housing jacket 6 Remove the four piece thermal insulation If space for the inst...

Page 8: ...tion Installation and commissioning of the storage tank shall only be done by appropriately qual ified installer The installer should inform the user of the functions of the product and pro vide the necessary information on its safe use CAUTION When heating water slight temporary di scharge from the safety valve can occur This is a correct safety valve function Any attempt to interfere in its oper...

Page 9: ...sure reducer option if the pressure in the system exceeds the allowable value HQ1 Strainer filter GP11 Hot water circulating pump GP12 Circulation pump return from the tank GP14 Circulation pump supply to the exchanger GP15 Pump for loading the hot water tank CM1 Hot water expansion vessel Fig 10 Preparing hot water using a plate heat exchanger and a BA ST water tank Fig 11 Loading of the BA ST ta...

Page 10: ...g 3 and Fig 5 Fill the storage tank with water and vent it after mak ing correct connections 1 Remove protecting plugs from the connector pipes 2 Connect the hot water intake line XL4 3 Connect the cold water supply line together with the required safety valves XL3 4 If the system has the hot water circulation system connect it to the connector pipe XL5 Otherwise plug the pipe 5 Connect all temper...

Page 11: ...ent without having to remove it and empty the tank interrupting operation of the storage tank This solution simplifies operation and additionally contributes to the reliability and long lifetime INFORMATION Inspection of the Protective Magnesium Anode It is forbidden to 5 Maintenance Fig 12 Insulated protective magnesium anode ture above 70 C This also eliminates the risk of Legionella bacteria gr...

Page 12: ...intensity PE M5 pin 0 3 mA Fig 14 Replacement of the protective magnesium anode Connect the anode protective conductor to the M5 pin fixed to the top head of the storage tank Once making the above steps the storage tank is ready to use Cleaning of the Storage Tank During the use of the tank the so called boiler scale precipitation occurs from the heated water The amount of deposited stone depends ...

Page 13: ... the inspection opening 10 Replace the insulation and inspection opening blanking plate Storage tank model Inspection opening diameter Tightening torque BA ST 9022 FE BA ST 9030 FE BA ST 9040 FE BA ST 9050 FE ø 120 25 5 Nm BA ST 9075 FE BA ST 9100 FE ø 180 35 5 Nm Table 1 Tightening torque Storage tank model Type Heating unit power Connec tor pipe dia BA ST 9022 FE ME 0015 1 5 kW 1 ME 0020 2 0 kW ...

Page 14: ... into account both the possibility of reuse of materials recycling that can be disassembled and separated from materials unsuitable for recycling as well as risks arising from the processing of materials not intended to reuse The purchased device consists in more than 90 of parts that can be recycled and reused so they are safe for the environment and human health The packaging in which the produc...

Page 15: ... 85 Max allowable instanta neous temp in the tank C 98 Max tank operating pressure bar 6 10 Electric heating module connection inch 1 female 1 female 2 female Corrosion protection ceramic enamel magnesium anode Anode connection inch 1 female 1 female Magnesium anode dimensions mm ø26x650 ø33x500 ø33x720 Weight kg 52 83 97 113 180 210 Acc to EU regulations No 812 2013 814 2013 9 Technical data Tabl...

Page 16: ...16 BA ST 9022 9100 FE Chapter 9 Technical data Dimensions Fig 18 Dimensions of the BA ST 750 9100 FE storage tanks C B W G D E F H I J O K L M N XL3 XL35 QQ1 XL4 XL9 UA2 UA1 XL8 XL5 XL54 UA3 ...

Page 17: ...osure mm ø16 Female XL5 Hot water circulation cal Male 1 Male UA3 Temp sensor enclosure mm ø16 Female XL8 Hot water supply cal Male 1 Male 1 Male XL4 Hot water outlet cal Male 1 Male 1 Male Dimen sions U m Tank BA ST 9022 FE BA ST 9030 FE BA ST 9040 FE BA ST 9050 FE BA ST 9075 FE BA ST 9100 FE B mm 665 743 844 897 1055 1165 C 600 676 774 832 977 1087 D 267 315 323 337 541 576 E 919 930 913 967 109...

Page 18: ...NOTES ...

Page 19: ......

Page 20: ......

Reviews: