C) For flow meter sizes 10 inches and larger, use the lugs provided to lift, move and position the
instrument.
Do not lift the instrument with a fork lift as this could cause the casing to buckle
and damage the internal coils.
2.2 Storage
If storing the unit, care should be taken to avoid damage. The unit must be stored in a non-condensing atmosphere
less than 100% relative humidity. Store between -50° F and 200° F.
3.0 MEChaniCal inSTallaTiOn
3.1 guidelines
installation guidelines
a) Only use the bolts and gaskets as described in the technical data of the
operating manual
b) Ensure the mains supply is switched off during installation.
Install the flow meter at a location, such that the pipe is always full at that location
LOW
HI
SET
LA
EPD
BDF
SET
HA
LOW
HI
SET
LA
EPD
BDF
SET
HA
DIRECTION OF FLOW
DIRECTION OF FLOW
MINIMUM 3D
MINIMUM 5D
FLO W DIRECTION
FLOW CONTR OLLER
VA LVE
D = PIPE DIAMETER
D
i
RECTION OF FLOW
LO W
H I
LA
BDF