background image

Safety instructions and user guide for the automatic pool cover  - 6/8

This document is the property of AS POOL - NextPool group and cannot be reproduced or communicated without our authorisation.

6

5. Winterisation advice

Winterisation advice is described below, however, it is 

the installer's responsibility to recommend a solution 

depending on the availability of the customer and the 

geographical location of the swimming pool.

• 

Carry  out  active  winterisation  by  operating  the 

circulation of the water and filtering during the coldest 

moments of the day (An anti-freeze thermostat can 

trigger filtering as soon as the air temperature falls 

below 0°).

• 

Keep the water level normal, excess water will drain 

from the overflow.

• 

Clean the slats unrolled over the pool using a high-

pressure cleaner and then sweep the pool and the 

storage trench. Treat the water with winterisation 

products.

• 

Keep your cover unrolled over the body of water and, 

if it is surrounded by a lot of vegetation, fit a netting, 

permeable cover over it in order to avoid the decay 

of leaves and other plant debris on the PVC slats. Do 

not store the cover rolled with an accumulation of 

leaves or debris which would trigger an irremediable 

decaying process causing encrusted stains to form 

on the PVC slats. This physical phenomenon is not 

covered by the guarantee for the slats.

• 

Protect the skimmers and piping exposed to freezing.

• 

Protect the motors from flooding.

• 

Cut the power supply to the electric box. 

• 

Do not operate the cover or touch the slats when 

they are ice bound. If there is a risk of the pool icing 

over, have the submerged shaft and the roller motor 

removed.

• 

For models using solar power, the batteries can remain 

in place if the solar panel is not covered and continues 

its charging function. If the panel is covered and can 

no longer charge using sunlight, the batteries must be 

disconnected and stored in a dry place. When putting 

back into service, let the batteries charge (a half day of 

sunlight) before operating the cover.

6. 

Guarantee

Our one year guarantee only covers the replacement 

or the repair of a defective part as well as all defects 

or  faults  in  the  context  of  the  installation,  use, 

maintenance and winterisation in compliance with our 

instructions.
It only comes into effect on the shipping date if the 

reseller  or  installer  returns  us  the  defective  parts 

postage paid for analysis.
The guarantee covers all of the electrical equipment 

providing that the wiring was carried out in accordance 

with  our  instructions  and  in  compliance  with  the 

standard C 15.100.
The guarantee does not cover the immersion of motors 

not designed for this purpose and the consequences of 

lightning.
Apart from the general one-year guarantee, we grant 

the following guarantees:

-  sending the guarantee form duly completed within 

8 days of the slatted cover's installation, gives right 

to an extension of the geared motor guarantee 

from 1 to 3 years free of charge

- the roller mechanics: 3 years (1)
- the slatted cover PVC slats: 3 year (2)
- solar panel: 10 ans
- batteries: 1 year.

(1)  The  guarantee  covers  the  resistance  of  the 

materials used with the exception of corrosion and 

deterioration of certain materials due to the use of 

any device producing an electro-chemical or electro-

physical  reaction,  which  generally  accelerates  the 

corrosion of metals.
(2) The guarantee covers the buoyancy, watertightness 

and articulation of the slats. The guarantee does not 

cover brownish stains and discolouration of the slats. 

Distortion of the blue translucent solar slats caused 

by use in disregard of our technical recommendations 

is also excluded. Damage caused by hail is excluded. 

All modifications to a slat voids the guarantee on the 

apron.
All labour costs for removal, assembly, travel, water 

supply, products, damages and interests as well as any 

claims for compensation for any cause whatsoever are 

excluded.

Summary of Contents for ABRIBLUE DIVER

Page 1: ...2021 AUTOMATIC SUBMERGED SAFETY COVER Installation manual Please read carefully and keep available for later use 01 2021 Version DIVER Axial motorisation S l a t t ed cover s sta n da r d Compliant wi...

Page 2: ...ring automatic covers since 1995 The advice will allow the user to make the best use of this equipment which should give compete satisfaction to its users Compliant with the highest requirements our s...

Page 3: ...the order 7 3 3 Duckboard hinge assembly 12 3 4 Rear shelf fixture option 15 4 Electric connections 4 1 Box with PLC 16 4 2 Bluetooth key operated control box 17 4 3 Connection box 18 4 4 Uncoupling 1...

Page 4: ...ontrol between the box and the key operated Bluetooth control box using 5 x 1 mm wire Separate cables carrying different voltages 24 V and 220 V by passing them through different sheaths which are spa...

Page 5: ...2 between 2 and 3 If B1 and B2 are equal continue with the next step otherwise correct the position of marks 3 and 4 and start the operation again until B1 B2 1 2 2 Overflow Fig 3 Plan to control the...

Page 6: ...er weighs 610 Kg and measures 5 6 x 0 6 x 0 8 h Fig 6 0 8 m x 0 6 m 0 8 m 0 6 m l 4 2 4 7 5 2 6 2 7 2 8 2 9 2 10 2 11 2 12 2 X 4 6 5 1 5 6 6 6 7 8 8 6 9 6 10 6 11 6 12 6 2 2 Reception Open the contain...

Page 7: ...forator a set of flat spanners socket wrenches and hex keys a set of screwdrivers a mallet pliers a level a glue gun a cutter a multimeter a tape measure a saw an angle grinder and a marker Fig 7 3 2...

Page 8: ...pairs of TFHC M10 x 35 mm screws important all 4 screws per flange must be fitted Fig 11A Pool greater than 10 m Fig 11B Fix each flange to the beam support using the 2 pairs of TFHC M10 x 35 mm scre...

Page 9: ...13 Position the nylon M8 nuts in the beam support brackets Fig 13 3 2 3 Assembling the shaft to the mechanism Fig 14 Assemble the motorised tube to the flange on the side opposite the motor following...

Page 10: ...el and if necessary adjust using the oblong holes on the bearing of the flange on the side opposite the motor Check the level of the shaft at each end with the water level 0 mm Fig 20 X1 X2 X1 X2 0 mm...

Page 11: ...24 Position a backflow flange and a PVC pipe which reaches your deck as per this diagram Fig 24 Fig 25 Position a cable tie in the hole of the motor flange provided for this purpose Pass the cable ins...

Page 12: ...Fig 31 Fig 32 Draping plate Place the duckboard upside down and then position the hinges opposite the holes in the duckboard Fix the hinges using TRPZ 4 8 x 13 screws and M6 double tooth lock washers...

Page 13: ...en fix the two frames Make sure to align the duckboard elements with each other 1 2 Fig 34 Fig 35 Caution strike the duckboard elements gently to avoid damaging them Fig 36 Lower the assembled duckboa...

Page 14: ...beam supports using the 2 nylon M8 x 40 mm pan headed screws Screw on the M8 nylon nuts Note In cases where a cable rises along the wall a cut out will need to be made on the PVC frame on the motor si...

Page 15: ...helf and drill the wall to a diameter of 12 mm and a depth of 70 mm Fig 41 Fig 42 On the stainless steel corner part position the TH M10 x 45 mm screws fit the 50 mm diameter neoprene seals behind the...

Page 16: ...r cable to the screw terminal to the left of the terminal blocks respecting the L and N symbols In the box connect the motor power wires of the connecting cable to the RED and BLACK terminals taking c...

Page 17: ...ted switch is connected in parallel remember to remove the key after each use Setting In Continuous press mode action on the key operated switch or the smartphone button is required for the cover to m...

Page 18: ...tside of the volume 0 see fig 1 and accessible at any time Box wall mounting Fix the control box to the wall using the supplied anchorsandscrewsusingthefixingholesprovided Position in a location shelt...

Page 19: ...move the pin blocker to access Turn the stainless steel pin a quarter turn so that it is perpendicular to the wall and pull The cover axis now rotates freely Manually accompany the unrolling of the co...

Page 20: ...urself above the roller with your back to the pool Press once if the motor is on the right Press once if the motor is on the left Fig 52 Using the control key unroll the cover and validate the positio...

Page 21: ...t present or of a different value check again making sure that the multimeter tips are in contact with the terminals and that your multimeter is calibrated and on the correct measurement position A vo...

Page 22: ...age upkeep and winterisation advice They give them the cover instructions They demonstrate the use of the cover and explain it functional limits The installer and end user fill in and sign the guarant...

Page 23: ...the NO contact is closed the NC contact is open These contacts are free of electric potential Cut off power resistive load 0 3A at 125v 1A at 30 VDC inductive load 0 2A at 125Vac 0 5A at 30VDC max vo...

Page 24: ...DIVER automatic submerged safety cover axial 24 24 24 Product DIVER axial motorisation Company AS POOL Address ZAC de la Rouveli re F 72700 SPAY LE MANS Phone 33 0 811 901 331 Fax 33 0 243 479 850 con...

Page 25: ...Safety instructions and user guide for the automatic pool cover Please read carefully and keep available for later use 02 2021 Version AE 12 018 11EN 02 2021 Slatted covers...

Page 26: ...anger to your children Drowning happens very quickly Children close to a pool require constant monitoring and active supervision even if they can swim The physical presence of a responsible adult is i...

Page 27: ...d especially on the BANCS in order to correctly position the slats on the roller when rolling in is complete or on the water when unrolling is complete On the model without limit switches make sure no...

Page 28: ...r level regulation overflow not clogged automatic filling correctly set Make sure that the area where the cover motor is located is fitted with a drain preventing the motor from being submerged at all...

Page 29: ...on the specificities of the pool AS POOL does not communicate directly with pool owners Have the automatic cover serviced by a swimming pool professional we recommend your swimming pool installer whos...

Page 30: ...t the batteries must be disconnected and stored in a dry place When putting back into service let the batteries charge a half day of sunlight before operating the cover 6 Guarantee Our one year guaran...

Page 31: ...Blue PVC Light grey PVC Galet grey PVC Blue tinted two ply PVC Clear polycarbonate Blue tinted translucent polycarbonate Blue tinted two ply polycarbonate Mother of pearl tinted two ply polycarbonate...

Page 32: ...c box check the 10A 30mA ground fault circuit breaker The on off button on the box is ON Fuses are in good condition 12 V or 24 VDC voltage on the motor power terminals when the key is turned Continui...

Reviews: