- Installation instructions for supplementary outriggers -
Via Mediterraneo, 6 - 42022 - Boretto - Reggio Emilia - Italy
Tel. +39 - 0522-96 30 08 - Fax +39 - 0522-96 30 39
- 33 -
Lower the foot plates one at a time by operating as follows:
18.2.2 Hydraulic stabilizer
Manual lock valve
(Pict. 34)
Open the manual lock valve (
1
), in order to allow the
lowering to the ground of the foot plate (
2
).
The valve is open when the lever is in position “
A
”.
Operate the lever of the valve bank and the flow divider
(if present) until the plate reaches the ground, without
unloading the suspensions of the vehicle.
Then put the manual lock valve back to “
C
” (closed)
position.
Double acting lock valve
Obviously the lock valve manual operation is omitted in
case of double acting lock valves.
18.2.3 Manually tilting hydraulic stabilizer
In case of tilting stabilizer legs, before operating the lock
valve, make sure that the cylinders are in vertical
position, with foot plates downwards, with the lock pin
(
1
) fully in and the split pin (
2
) inserted. If not so, remove
the split pin, pull out the lock pin and turn the stabilizer
leg with the plate downwards. Lock the leg by the lock
pin and the split pin. Open the lock valve (
3
) and operate
relevant lever (
4
) of the valve bank until the stabilizer
foot plate (
5
) reaches the ground, as described for the
standard hydraulic stabilizer. When duly positioned,
close the valve (
3
) on the stabilizer (Pict. 35).
ATTENTION
If the stabilizer is not in a stable vertical position, when removing the lock pin, it must be properly
supported, in order to prevent it from falling downwards, causing damages or injuries.
1
3
5
4
2
Pict. 34
Pict. 35
1
C
C
C
C
C
A
A
A
A
A
2
- Use and maintenance manual -