- Installation instructions for supplementary outriggers -
Via Mediterraneo, 6 - 42022 - Boretto - Reggio Emilia - Italy
Tel. +39 - 0522-96 30 08 - Fax +39 - 0522-96 30 39
- 26 -
14 - INSTRUCTIONS FOR FIXING AND CONNECTING THE KIT MICROSWITCHES
FOR NOT LOCKED EXTENDABLE RODS
The kit warns the driver, when manually operated extension rods are not locked in the transport position. That kit is to be ordered
separately, and is supplied with instructions sheet.
WIRING INSTRUCTIONS (Pict. 28):
Microswitches (1) e (2) of the supplementary outrigger must be normally
open (NO) and series connected each other, by means of the bus bar (3).
Should the extensions of the crane main stabilizer be manually operated,
also their microswitches (4) and (5) will have to be normally open (NO)
and series connected each other and with the previous ones, layed on the
line supplying the solenoid of the relay (6). The contact (7), controlled by
the relay, must be normally closed (NC) on the line supplying the warning
light (8) in the driver’s cab, and series connected with the truck ignition
key (9). The warning light must be a RED lamp or LED.
FITTING OF THE COMPONENTS (Pict. 29):
Place the plate (1) on the centreline of the main beam, on the vertical
wall. Then, fix it with two small welds through holes (3).
Following the contour of the plate (1), apply a silicone bead to avoid penetration between and subsequent formation of rust.
Drill the wiring box (2), with three ø19 holes (4) as shown in pict. 29.
Fix the wiring box (2) on the plate, using the two screws (5), through holes (6).
Fit the holes (4) with relevant wire clamps (7) and secure them with relevant counternuts (8).
Mount, on each side of the beam, the two microswitches (11), fixing along with their spacer (13) on the locking latches (12) by
means of bolts (9)+(10) securing with soft loctite on their threads.
Drive the free end of the microswitches wires (14) into the box through the wire clamps (7).
Connect wires on the bus bar (15) following to the wirings shown in pict. 28.
Apply the self-adhesive clips (16) on the beam.
Secure the wires (14) to the adhesive clips (16), using cable ties (17).
Tighten the caps (18) on every wire clamp (7).
Close the box (2) with its cover (19), tightening the screws (20).
FINAL CHECKINGS:
With the truck ignition key turned ON:
The red lamp in the driver’s cab must be switched OFF when both lateral extensions are locked. The red lamp must be light ON if one
or both the lateral extensions are not locked.
Pict. 29
Pict. 28
2
6
3
5
1
4
7
8
9