background image

 

AeroVent® 1 Manual / 4290.0416   

 

AeroVent

®

 1

 

ALWAYS wear safety goggles or protective eye-wear when operating the unit

MAINTENANCE 

ITEM 

CHECK 

*REPLACE 

Lid Gasket 10004249 

 

Before each use 

As Necessary 

Carbon Filters 100001941  (single)       

10001860  (2 pack) 

Monthly 

Every 60 days or 600  cans, more 

often for full cans 

Cobalt Points  10003377 

 

Before Each use 

As Necessary 

Bellow 10003791 

 

Every 180 days 

As Necessary 

Operating Clamp 10004208 

Before each use 

Lubricate regularly with light oil. 

(3-in-1, WD-40 etc.) 

 

 

    

      

       

 

 

 

PARTS LIST

 

Item   

 

 

 

Part   

Number    Description 

 

Number 

Item   

 

 

 

Part 

Number   Description  

 

Number

     Main  Base Plate 

 

10004285 

 

     Support  Foot  (2 req) 

10004262 

 

     Operating  Handle   

10004208 

 

     Swivel  Foot  

 

10003788 

 

     Lid  Handle   

 

10004195 

 

     Lid  Grommet   

 

10002410 

 

 

     For plunger  block   

 

 

     Plunger  Block  Kit     

10004248 

 

     

(2”, 2.5” and 3”)   

 

     Trough  Liner  w/can stop  10003970 

9  

     Trough  Liner  Grommet 

10001874 

10 

     Lid  Gasket   

 

10004249 

11 

     Trough  Bellow 

 

10003791 

12 

     Trough  Spring 

 

10004257 

13 

     Cobalt  Point 

 

10003377 

14 

     Filter  Housing  & Filter 

10001940 

15 

     Carbon  Filter  replacement  element   

 

     Package of 2 

 

10001860 

16 

     Single 

 

 

10001941 

17 

     Grounding  Cable  w/clamp  10003914 

18 

     Left Shroud   

 

10004286 

19 

     Right  Shroud 

 

10004287 

20 

     Bellows  Clamp  (2 req) 

10003794 

21 

     Set Screw 10-32  x 5/8” 

10004167 

 

Swivel Foot  

#4 

 

Operating 
Handle #3 

Filter Housing 

#14 

Support Foot   

#2 

Lid 

gasket 
#10 

Right Shroud 

#19 

Left Shroud 

#18 

Trough liner w/ 

can stop #8 

Trough Liner  
Grommet #9 

Page 4 of 7

Summary of Contents for AeroVent 1

Page 1: ...AeroVent 1 Manual 4290 0416 AeroVent 1 Product Manual...

Page 2: ......

Page 3: ...lations on your purchase of the AeroVent 1 aerosol can depressurizer The AeroVent 1 has been designed to puncture and drain aerosol cans that have been used and are mostly empty It is not intended to...

Page 4: ...when not in use Store in a cool low temperature well ventilated place away from heat and ignition sources Use only in well ventilated area Avoid contact with eyes skin and clothing Wear appropriate pe...

Page 5: ...r the handle and adjust the swivel foot so that it is centered in the plunger block Completely tighten all nuts and bolts of the handle assembly to the mounting post at this time Pic 2 5 Open lid and...

Page 6: ...tly full leave the handle in the locked position for 45 60 seconds to allowcan to drain completely PRECAUTIONARY WARNING Do not use the AeroVent for draining expanding foam sealant aerosol products or...

Page 7: ...04285 2 Support Foot 2 req 10004262 3 Operating Handle 10004208 4 Swivel Foot 10003788 5 Lid Handle 10004195 6 Lid Grommet 10002410 For plunger block 7 Plunger Block Kit 10004248 2 2 5 and 3 8 Trough...

Page 8: ...op Bellows may have to be gently pried off of lower bushings to rotate assembly up Rotate the trough assembly upward and allow it to rest against the lid 4 Loosen the setscrew with a 3 32 hex key and...

Page 9: ...nt 1 Assembly Drawing AeroVent 1 Manual 4290 0416 Operating Handle 3 Swivel Foot 4 Cobalt Point 13 Bellows Clamp 20 Trough Bellow 11 Trough Spring 12 Support Foot 2 Set Screw 21 Right Shroud 19 Page 6...

Page 10: ......

Page 11: ...he complete guidelines for warranty and returns please visit www newstripe com guidlinesforwarrantyandreturn Gasoline engines compressors pumps including airless and Transaxles are furnished with thei...

Reviews: