ALWAYS wear safety goggles or protective eye-wear when operating the unit
!
COBALT POINT REPLACEMENT
(See Assembly Drawing Page 6)
HELPFUL HINT:
Leave the unit mounted on the drum to replace cobalt points.
1.
Open the lid and remove the left and right shrouds.
2.
Loosen the bottom clamp on the bellows. There is no need to loosen the top bellows clamp, unless the
bellows are damaged and need replaced.
3.
Remove the trough liner can stop.
Bellows may have to be gently pried off of lower bushings to rotate
assembly up.
Rotate the trough assembly upward and allow it to rest against the lid.
4.
Loosen the setscrew with a 3/32” hex key and then replace the point. Tighten the setscrew against the new
point. Do not use locktight on this setscrew.
5.
Re-assemble the unit in reverse order.
CARBON FILTER REPLACEMENT
1)
Remove the wing nut on the top of the housing cover.
2)
Lift off the cover and remove the used filter element.
3)
Install the new filter element.
4)
Replace the cover and hand tighten the wing nut securely.
5)
Dispose of the old filter appropriately.
Filter Housing
Carbon Filter Element
Page 5 of 7