background image

 

AeroVent® 1 Manual / 4290.0416   

 

 

AeroVent

®

 1 

ALWAYS wear safety goggles or protective eye-wear when operating the unit

 

OPERATION 

1)

 

Lift the operating handle to release clamp, and open the AeroVent

®

 1 lid.   

2)

 

Can stop should  be in slots at front of the trough liner.   

 

3)

 

Insert 1 aerosol can with 

the bottom of the can pointing toward the clamp, 

and up against the forward stop. 

 

4)

 

Close the lid.  Operate by pushing  down on the operating handle. (The clamp will  engage the lid  and push the lid 

down).  

5)

 

Push down until  the operating clamp “locks” into place (“Puncture & Drain position”).  The aerosol can has now 

been punctured.  Wait 15-30 seconds to allow  can to drain.   You may now lift  the handle to the “unload”  position 

and open the lid  to remove the can. 

Note:  If aerosol cans are mostly full, leave the handle in the locked position for 45-60 seconds to allow can to 

drain completely.   

 

 

PRECAUTIONARY WARNING!

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Do not use the AeroVent

®

 for draining  expanding  foam 

sealant aerosol products or spray adhesive products.

 

 

Always use the correct plunger block for the diameter of the 

can that you are draining. 

 

The clamp must remain locked until  the can drains. 

 

To insure that the can is drained,  wait 15-30 seconds before 

un-locking  the clamp and opening  the lid.

 

 

If a can is full  when punctured, wait at least 1 minute  before 

opening  the unit.  Full  cans take longer to empty and may 

discharge fumes or liquids  if the unit  is opened too soon.

 

 

We recommend changing the carbon filter every 60 days or 

600 cans.  If cans contain larger amounts of remaining  liquids, 

change the filter more often.  Also, we do not recommend 

allowing  the drum to become more than 70% (2/3) full.   An 

air space is needed in the drum to allow  for draining  and 

venting  of fumes

.

 

 

 

 

 

 

Page 3 of 7

Summary of Contents for AeroVent 1

Page 1: ...AeroVent 1 Manual 4290 0416 AeroVent 1 Product Manual...

Page 2: ......

Page 3: ...lations on your purchase of the AeroVent 1 aerosol can depressurizer The AeroVent 1 has been designed to puncture and drain aerosol cans that have been used and are mostly empty It is not intended to...

Page 4: ...when not in use Store in a cool low temperature well ventilated place away from heat and ignition sources Use only in well ventilated area Avoid contact with eyes skin and clothing Wear appropriate pe...

Page 5: ...r the handle and adjust the swivel foot so that it is centered in the plunger block Completely tighten all nuts and bolts of the handle assembly to the mounting post at this time Pic 2 5 Open lid and...

Page 6: ...tly full leave the handle in the locked position for 45 60 seconds to allowcan to drain completely PRECAUTIONARY WARNING Do not use the AeroVent for draining expanding foam sealant aerosol products or...

Page 7: ...04285 2 Support Foot 2 req 10004262 3 Operating Handle 10004208 4 Swivel Foot 10003788 5 Lid Handle 10004195 6 Lid Grommet 10002410 For plunger block 7 Plunger Block Kit 10004248 2 2 5 and 3 8 Trough...

Page 8: ...op Bellows may have to be gently pried off of lower bushings to rotate assembly up Rotate the trough assembly upward and allow it to rest against the lid 4 Loosen the setscrew with a 3 32 hex key and...

Page 9: ...nt 1 Assembly Drawing AeroVent 1 Manual 4290 0416 Operating Handle 3 Swivel Foot 4 Cobalt Point 13 Bellows Clamp 20 Trough Bellow 11 Trough Spring 12 Support Foot 2 Set Screw 21 Right Shroud 19 Page 6...

Page 10: ......

Page 11: ...he complete guidelines for warranty and returns please visit www newstripe com guidlinesforwarrantyandreturn Gasoline engines compressors pumps including airless and Transaxles are furnished with thei...