PLATINUM Series Controllers User’s Guide
22
Complete Menu Structure
Level
2
Level
3
Level
4
Level
5
Level
6
Notes
StRt
Initiates autotune after StRt confirmation
_P_
____
Manual Proportional Band setting
_I_
____
Manual Integral Factor setting
_d_
____
Manual Derivative Factor setting
____
Low clamping limit for Pulse, Analog Outputs
____
High clamping limit for Pulse, Analog Outputs
ENbL
Enable fuzzy logic adaptive tuning
dSbL
Disable fuzzy logic adaptive tuning
oFF
Use SP1, not remote Setpoint
oN
4–20
Remote analog Input sets SP1; range: 4–20 mA
Note:
This submenu is the same for all RM.SP ranges.
RS.Lo
____
Min Setpoint for scaled range
IN.Lo
____
Input value for RS.Lo
RS.HI
____
Max Setpoint for scaled range
IN.HI
____
Input value for RS.HI
0–24
0–24 mA
0–10
0–10 V
0–1
0–1 V
No
Multi-Ramp/Soak Mode off
yES
Multi-Ramp/Soak Mode on
RMt
M.RMP on, start with digital input
____
Select program (number for M.RMP program), options 1–99
Guaranteed Ramp: soak pnt must be reached in ramp time
SoAk
Guaranteed Soak: soak time always preserved
CYCL
Guaranteed Cycle: ramp can extend but cycle time can’t
Note: tIM.F does not appear for 6 digit display that use a HH:MM:SS format
“Minutes : Seconds” default time format for R/S programs
HH:MM
“Hours : Minutes” default time format for R/S programs
StOP
Stop running at the end of the program
HOLd
Continue to hold at the last soak setpoint at program end
LINk
____
Start the specified ramp & soak program at program end
1 to 8 Ramp/Soak segments (8 each, 16 total)
____
Select segment number to edit, entry replaces # below
____
Time for Ramp number, default = 10
MRE.#
oFF
Ramp events on for this segment
oN
Ramp events off for this segment
MSP.#
____
Setpoint value for Soak number
MSt.#
____
Time for Soak number, default = 10
MSE.#
oFF
Soak events off for this segment