Page 23
FEATURES AUTO GENSTART CONFIGURATION SCREENS AGS SCREEN 2
The second Autogen Configuration screen is
accessed by pressing the Next Button located
on the first Autogen Configuration screen or by
pressing the “Prev” Button located on the third
Autogen Configuration screen. This screen
allows you to change the following settings:
Autocharger Start Volts
(DC Voltage)
If the Auto Charger function is Enabled, this
setting determines the voltage level that will
automatically start the generator.
When the house battery voltage drops below
this value for approximately 2 minutes the
generator will automatically start and run
until the charger goes into Float Mode or the
Autocharger Max Run Time setting time has
expired.
Select value using the Up / Down Arrows
Autocharger Max Run Time
(min Time Set)
This setting controls the maximum time the
generator will run when started by the
Autocharger function.
Select value using the Up / Down Arrows
Topoff Volts
(DC Voltage)
This setting determines the voltage level that
will automatically start the generator based
on the Topoff Run Time settings.
Select value using the Up / Down Arrows
Topoff Run Time
(min Time Set)
This setting determines the amount of time
before Quiet Time begins to automatically
start the generator, if the Auto Charger
function is Enabled and the house battery
voltage is below the Topoff Volts setting.
If these conditions are met, the generator will
automatically start and run until Quiet Time
begins.
Select value using the Up / Down Arrows
FEATURES AUTO GENSTART CONFIGURATION SCREENS AGS SCREEN 3
The third Autogen Configuration screen is
accessed by pressing the Next Button located
on the second Autogen Configuration screen or
by pressing the “Prev” Button located on the
fourth Autogen Configuration screen.
This screen controls the generator Quiet Time
settings. During Quiet Time the generator is
inhibited from running. If the generator is
running in an Auto Gen function, the generator
will stop running during Quiet Time. When
Quiet Time expires, the generator will restart
and complete the Auto Gen cycle if required.
The Quiet Time Function is disabled if the Quiet
Time Begin and Quiet Time End setting are set
to the same value.
This screens controls the following settings:
Quiet Time Begin
Time of Day
Sets the Quiet Time start time
Select value using the Up / Down Arrows
Quiet Time End
Time of Day
Sets the Quiet Time end time
Select value using the Up / Down Arrows
Summary of Contents for SilverLeaf RV-C Control System
Page 1: ...2012 Newmar Corporation October 2011 SilverLeaf RV C Control System Training Manual ...
Page 2: ......
Page 41: ...Page 39 ALL ELECTRIC OPTION LP STANDARD ...
Page 43: ...Page 41 ...
Page 44: ...Page 42 ...
Page 45: ...Page 43 EXDP TANK CAPACITIES KGDB TANK CAPACITIES ...
Page 46: ...Page 44 ...
Page 47: ...Page 45 ...
Page 48: ...Page 46 ...
Page 49: ...Page 47 ...
Page 50: ...Page 48 ...
Page 51: ...Page 49 ...
Page 52: ...Page 50 ...
Page 53: ...Page 51 ...
Page 54: ...Page 52 ...
Page 55: ...Page 53 ...
Page 56: ...Page 54 ...
Page 57: ...Page 55 ...
Page 58: ...Page 56 ...
Page 59: ...Page 57 ...
Page 60: ...Page 58 Blank Page ...