CONDITION
POSSIBLE CAUSE
SOLUTION
VI) TROUBLESHOOTING (cont.)
3. Charger output is not
properly connected to
batteries.
3. Refer to d.c. wiring
installation diagram for
proper connection to
batteries.
4. Blown output fuse
4. Replace with another of
correct value (see section
III D, “d.c. output Wiring”)
5. Defective charger.
5. Return for analysis/
repair by servicing dealer
where charger was
purchased or contact
NEWMAR for Return
Authorization Number.
D. Charger repeatedly
blows input fuse with no
batteries connected.
Internal short.
Same as above.
E. Reverse polarity
connection to charger has
caused charger to stop
charging.
d.c. Output fuse and
possibly other
components blown.
Replace output fuse with
another of correct value. If
fuse again blows, return to
servicing dealer or contact
NEWMAR for Return
Authorization Number.
F. High output voltage
measured across charger
output terminals.
1. Batteries not connected
to charger. It is normal to
read 1/2 volt higher across
any output bank when no
batteries are connected.
1. Check for tight
connection of charging
leads from charger to
batteries.
2. Equalize function
activated
2. Check to verify proper
installation and operation
of equalize timer
G. Charger will not stay in
bulk/absorption mode
when re-initialize button
on remote panel pressed
Batteries at or nearing full
charge (Not a problem
condition)
Verify proper operation by
pressing reinitialize button
(on optional remote panel)
and applying a large d.c.
load
C. Charger does not
charge. (continued)
VII) SPECIFICATIONS
INPUT RANGE (ALL MODELS): 85-135/170-270V a.c. (via selector switch or a.c.
input connector/adaptor); 47-63 HZ (automatic)
Derate Models, PT24-20CE and PT-40CE from 560 watts @ 95V a.c. to 500 watts
@ 85V a.c.
OUTPUT BANKS (ALL MODELS): 3
OUTPUT VOLTAGES WITHOUT TEMPERATURE COMPENSATION OPTION:
12 VOLT MODELS
24 VOLT MODELS
Charge
Float
Charge
Float
Setting
@ 50 % load
@ .1 amp load
@ 50 % load
@ .1 amp load
Gel-Cell
14.0V d.c.
13.6V d.c.
28.0V d.c.
27.2V d.c.
Lead Acid
14.2V d.c.
13.4V d.c
28.4V d.c.
26.8V d.c.
TEMPERATURE COMPENSATION:
- 3 mV per cell per ° F
- 5 mV per cell per ° C
TEMPERATURE RATINGS:
-40°C to + 60°C; Derate linearly from 100 % @ 50°C to 75 % @ 60°C
PROTECTION: Input fuse; Output fuse for reverse polarity protection; Current
limiting; Automatic high temperature power reduction; Time and load controlled
high rate charge circuit; Ignition protected
Model
Input Amps
Output
Weight
115/230V
Volts Amps (Cont.)
Lbs. Kg.
PT-20CE
4.3 / 2.2
12
20
11 5
PT-40CE
8.5 / 4.3
12
40
12 5.5
PT-70CE
16 / 8
12
70
24 10.9
PT-24-20CE
8.5 / 4.3
24
20
12 5.5
PT-24-35CE
16 / 8
24
35
24 10.9
INPUT/OUTPUT FUSE VALUES:
Model
a.c. Input Fuse
d.c. Output Fuse
115V a.c
230V a.c.
PT-20CE
AGC-6
AGC-3
(1 ea.) ATC-30
PT-40CE
ABC-12
AGC-6
(2 ea.) ATC-30
PT-70CE
ABC 20
ABC-12
(1 ea.) HBO-100
PT-24-20CE
ABC-12
AGC-6
(1 ea.) ATC-30
PT-24-35CE
ABC-20
ABC-12
(2 ea.) ATC-30
26
27