NewMar Phase Three PT-CE Series Installation & Operation Manual Download Page 1

INSTALLATION/OPERATION MANUAL

PT-CE SERIES

Models:

PT-20CE, PT-40CE, PT-70CE

PT-24-20CE, PT-24-35CE

USA Headquarters:

 P.O. Box 1306 • Newport Beach, CA 92663 • Phone: 714-751-0488 • Fax: 714-957-1621

Shipping: 2911 W. Garry Ave., Santa Ana CA 92704

e-mail: [email protected]

Euro Warehouse:

 Holland • Phone: +31-35-603-2494 • Fax: +31-35-603-2149

e-mail:  [email protected]

THREE STAGE SMART CHARGER/

DC POWER SUPPLY

LIMITED WARRANTY

NEWMAR warrants with the original purchase of products sold by NEWMAR, that they shall be
free from defects in material and workmanship for two years from the date of purchase.

In the event of a product failure caused by defect of material or workmanship you must return the
entire product with the original packing if possible, freight pre-paid, to the place of purchase or to
NEWMAR, 2911 W. Garry Avenue, Santa Ana, California 92704. Besides paying to send back the
product, you must include proof of purchase reflecting where the product was purchased, the date
of purchase and a written explanation of the alleged defect. If this product is determined to be
defective by NEWMAR, we will repair the product and ship it back to you without charge. If non-
repairable within 30 days, we will ship an equivalent or better replacement product or provide you
with a refund of your purchase price.

Repairs or adjustments to be made on the defective product shall be determined by NEWMAR in
its sole discretion. If you have any questions concerning this Limited Warranty, contact us at the
above address or call Customer Service at 1-800-854-3906.

This Limited Warranty does not apply to products that have not been installed properly or maintained
adequately. This Limited Warranty does not apply to damage through accident, negligence, misuse,
abuse or normal wear and tear. Further, this warranty does not cover products that have been
altered or modified from their original sale condition. For information regarding proper installation,
please consult the instructions enclosed with the product. You may contact NEWMAR or an
authorized retailer for additional installation instructions. It is your responsibility to check the product
upon receipt for any damage during shipping and to contact the carrier or shipper regarding such
damage. No person including any NEWMAR dealer, is authorized to assume any further liability
for NEWMAR beyond this Limited Warranty, in connection with the products sold by NEWMAR.  A
customer’s sole and exclusive recourse against NEWMAR is this Limited Warranty, regardless of
a customer’s recourse against a seller.

THERE ARE NO OTHER WARRANTIES  EXPRESS OR IMPLIED WHICH EXIST BEYOND THE
TERMS OF THIS LIMITED WARRANTY. THIS LIMITED WARRANTY IS NEWMAR’S SOLE
OBLIGATION TO YOU FOR THIS PRODUCT AND CONSTITUTES YOUR EXCLUSIVE REMEDY
UNDER THE LAW. NEWMAR SHALL NOT BE LIABLE FOR ANY INCIDENTAL,
CONSEQUENTIAL OR INDIRECT DAMAGES CAUSED AS A RESULT OF ANY DEFECT IN
WORKMANSHIP, REPAIR OR MATERIAL WORKMANSHIP REPAIR OR REPLACEMENT OF
THIS PRODUCT. NEWMAR IS NOT RESPONSIBLE FOR ANY DAMAGE THIS PRODUCT
CAUSES TO ANY OTHER EQUIPMENT OR ANY OTHER PRODUCT.

Some states do not allow limitations on how long an implied warranty lasts, so the above limitation
may not apply to you. Also some states do not allow the exclusional limitation of incidental or
consequential damages, so the above limitation or exclusion may not apply to you. Finally, this
warranty gives you specific legal rights; however, you may also have other rights which vary from
state to state.

M-PT-CE-F

All manuals and user guides at all-guides.com

all-guides.com

Summary of Contents for Phase Three PT-CE Series

Page 1: ...y does not apply to damage through accident negligence misuse abuse or normal wear and tear Further this warranty does not cover products that have been altered or modified from their original sale co...

Page 2: ...detailed later in this manual Three step smart charging bulk absorption float Gel cell lead acid switch selects optimum charge float voltages based on battery type Multiple output banks charge indepen...

Page 3: ...wise damaged take it to a qualified serviceman 11 Do not disassemble the charger take it to a qualified serviceman when service or repair is necessary Incorrect reassembly may result in a risk of elec...

Page 4: ...D CABLE CLAMP except PT 70CE and PT 24 35CE 1 INPUT POWER CORD STRAIN RELIEF PT 70CE and PT 24 35CE only 1 INPUT FUSE FOR 115V a c APPLICATIONS 230V a c FUSE INSTALLED 1 a c INPUT WIRING COVER PT 70CE...

Page 5: ...ified service personnel should access the output terminals of the charger Pull off the black plastic terminal cover at the bottom of the front panel to expose the d c output terminals and attach d c w...

Page 6: ...ng conditions If the d c fuse s blow this may indicate a reverse polarity hook up or an internal short Always disconnect a c to the charger before checking fuses To check or replace the d c fuse the c...

Page 7: ...reen or Green with Yellow Stripe a c Ground safety earth As shipped from the factory the charger is set up for 230V a c input For 115V a c applications you must 1 Slide the recessed 115 230 input sele...

Page 8: ...se Replacement The a c input of your charger is protected by an input fuse The input fuseholder is located near the bottom of the unit on the left side 20 and 40 amp models or on the bottom of the uni...

Page 9: ...remote panel Note The PT CE charger is able to deliver its full rated output current while in the float mode Installation Note The time out circuit of the PT CE charger has been set at about 8 10 hou...

Page 10: ...ng in excessive loss of electrolyte Conversely if the batteries are in a consistently cool environment they may be chronically undercharged resulting in sulfation of the battery plates Either of these...

Page 11: ...er function plug in PCB which is located on the right side of the charger Locate TP1 and TP2 4 Route the two control wires of the timer through the bottom of the cover assembly and solder the ends to...

Page 12: ...he lower left hand corner of the charger front panel B Constant Versus Occasional Use In general it is recommended that the charger be left connected continuously to the a c distribution system so tha...

Page 13: ...cing power output 3 Clean or replace clogged fan filter or replace fan if necessary B Charger continues to charge at 3 amps or more does not taper back in charge 1 d c load still connected to batterie...

Page 14: ...a problem condition Verify proper operation by pressing reinitialize button on optional remote panel and applying a large d c load C Charger does not charge continued VII SPECIFICATIONS INPUT RANGE AL...

Page 15: ...s and scrub the battery with a baking soda solution Rinse with fresh water and dry with a clean cloth You may wish to purchase a set of terminal post corrosion prevention rings These are alkali satura...

Page 16: ...an accurate voltage reading on the output of the charger with no batteries attached This is checked merely to ensure that you do not have an open circuit on the output The battery charger has a therm...

Reviews: