Enter Setup
】
127
【
Exit Setup
】
Parity Check
A check digit is optional for Codabar and can be added as the last digit. It is a calculated value used to verify the
accuracy of the data. By default, the scanner does not run parity check.
No Parity Check:
The scanner transmits Codabar barcodes as is.
Do Not Transmit Check Digit After Parity Check:
The scanner will run a parity check using the last digit of
Codabar barcode as check digit. Barcodes passing the check will be transmitted except the last digit, whereas those
failing it will not be transmitted.
Transmit Check Digit After Parity Check:
The scanner will run a parity check using the last digit of Codabar
barcode as check digit. Barcodes passing the check will be transmitted, whereas those failing it will not be
transmitted.
**
【
No Parity Check
】
【
Transmit Check Digit After Parity Check
】
【
Do Not Transmit Check Digit After Parity Check
】
Note:
If the
Do Not Transmit Check Digit After Parity Check
option is enabled, Codabar barcodes with a length that
is less than the configured minimum length after having the check digit excluded will not be decoded. (For example,
when the
Do Not Transmit Check Digit After Parity Check
option is enabled and the minimum length is set to 4,
Codabar barcodes with a total length of 4 characters including the check digit cannot be read.)
Summary of Contents for NLS-HR1550-3E
Page 1: ...NLS HR15 Series NLS HR1550 3E Cordless 1D Barcode Scanner User Guide...
Page 22: ...12 Depth of Field Fig 1 8...
Page 24: ...14 Dimensions of Scanner Side View Fig 1 9 Front View Fig 1 10...
Page 25: ...15 Top View Fig 1 11 Dimensions of CD15 Cradle Fig 1 12...
Page 32: ...Enter Setup Exit Setup 22 Configuration Process Flow...
Page 166: ...Enter Setup Exit Setup 156 abcdefghijklmnopqrstuvwxyz...
Page 176: ...166 A F A B C D E F...