background image

 

Enter Setup

 

 

**

Exit  Setup

                                                                                                                                                                                   

66

 

 

UPC-A 

Restore Factory Defaults 

 

 

Restore the Factory Defaults of UPC-A

 

 

 

 

Enable/Disable UPC-A 

 

 

 

**

Enable UPC-A

 

 

 

Disable UPC-A

 

 

If the scanner fails to identify UPC-A barcodes, you may first try this solution by scanning 

the 

Enter Setup

 barcode and then 

Enable UPC-A

 barcode. 

 

 

Transmit Check Digit 

UPC-A is 12 digits in length with the last one as its check digit used to verify the integrity of the data. 

 

 

 

**

Transmit UPC-A Check Digit

 

 

 

Do Not Transmit UPC-A Check Digit

 

Summary of Contents for HR3260-CS

Page 1: ...NLS HR3260 Series Cordless 2D Barcode Scanner User Guide...

Page 2: ...function or design at any time without notice The information contained herein is subject to change without prior notice The products depicted in this manual may include software copyrighted by Fujia...

Page 3: ...dded Note Maximum barcode length supported by the scanner is 1024 bytes in the Introduction section of Chapter 5 May 12 2015 V1 0 4 Added the following keyboard types Belgium Russia Sweden and Portuga...

Page 4: ...Port 6 USB RS 232 Port 7 Connecting Cradle to a Host 7 Use USB Cable 8 Use RS 232 Cable 9 Power On Sleep Power Off Reboot 10 Maintenance 10 Dimensions of Scanner 11 Side View 11 Front View 11 Top View...

Page 5: ...al Mode 27 Decode Session Timeout 27 Timeout between Decodes Same Barcode 28 Sense Mode 29 Decode Session Timeout 29 Image Stabilization Timeout 30 Continue after Good Read 30 Timeout between Decodes...

Page 6: ...USB HID POS 49 Introduction 49 Access the Scanner with Your Program 49 Acquire Scanned Data 50 Send Data to the Scanner 50 VID PID 50 Chapter 5 Symbologies 51 Introduction 51 General Settings 51 Disa...

Page 7: ...de Required 64 Transmit System Character 0 64 UPC E Extension 65 UPC A 66 Restore Factory Defaults 66 Enable Disable UPC A 66 Transmit Check Digit 66 Add On Code 67 Add On Code Required 68 Transmit Pr...

Page 8: ...y Defaults 85 Enable Disable Code 93 85 Set Length Range for Code 93 86 Check Digit Verification 87 UCC EAN 128 88 Restore Factory Defaults 88 Enable Disable UCC EAN 128 88 Set Length Range for UCC EA...

Page 9: ...Disable Standard 25 105 Set Length Range for Standard 25 106 Check Digit Verification 107 Plessey 108 Restore Factory Defaults 108 Enable Disable Plessey 108 Set Length Range for Plessey 109 Check Di...

Page 10: ...4 Set Custom Prefix 124 AIM ID Prefix 125 Code ID Prefix 125 Restore All Default Code IDs 126 Modify Code ID 126 Custom Suffix 130 Enable Disable Custom Suffix 130 Set Custom Suffix 130 Terminating Ch...

Page 11: ...r 3 Inquiry Command Describes how to obtain the information of HR32 cordless scanner by scanning programming barcodes Chapter 4 Communication Settings Describes how to configure communication mode ser...

Page 12: ...s manual This icon indicates this information requires extra attention from the reader This icon indicates handy tips that can help you use or configure the scanner with ease This icon indicates pract...

Page 13: ...lop a better understanding of this manual This chapter is written for normal users maintenance staff and software developers Features of the HR32 Comprehensive data capture most 1D and 2D barcodes Fas...

Page 14: ...decoded successfully Battery is fully charged Blue Zigbee is available Red Data transmission failed Device is charging Purple Firmware update is in progress There is data in FLASH memory Decode Trans...

Page 15: ...s P Batch Transmission M Pair Search LEDs Zigbee LED blue Zigbee is available Battery LEDs green Indicates battery level four levels Fig 1 3 Batch Transmission Pair Search Battery LEDs Zigbee LED Powe...

Page 16: ...navailable the decoded data will be first stored in the flash memory in a FIFO first in first out manner and be sent automatically to the cradle when Zigbee becomes available Batch Mode The decoded da...

Page 17: ...such as PC POS or any intelligent terminal with USB or RS 232 port via a communication cable either USB or RS 232 cable USB USB port on the Host RS 232 RS 232 port on the Host Note Please check the po...

Page 18: ...t through a USB cable with RJ45 and USB connectors 1 Plug the RJ45 connector into the data port see Fig 1 3 on the cradle 2 Plug the USB connector into the USB port on the Host 3 Plug the supplied pow...

Page 19: ...ough an RS 232 cable with RJ45 and RS 232 connectors 1 Plug the RJ45 connector into the data port see Fig 1 3 on the cradle 2 Plug the RS 232 connector into the RS 232 port on the Host 3 Plug the supp...

Page 20: ...fault 5 minutes programmable will be automatically turned off To change the time period see the Power Off Timeout in Chapter 2 Rebooting the scanner If the scanner stops responding to input or runs ab...

Page 21: ...11 Dimensions of Scanner Side View Fig 1 8 Front View Fig 1 9 Top View Fig 1 10 unit mm unit mm unit mm...

Page 22: ...12 Dimensions of CD32 Cradle Fig 1 11...

Page 23: ...2 Aim the red beam across the center of barcode as shown in Fig 1 12 3 Release the trigger when the red beam goes off If the barcode is decoded successfully the scanner will beep and the decoded data...

Page 24: ...thin a certain range of scan angles Any unreasonable deviation may cause decoding failure Scan angles of the scanner Pitch 55 0 Roll and 0 Skew Fig 1 13 Roll 360 0 Pitch and 0 Skew Fig 1 14 Skew 55 0...

Page 25: ...them This programming method is most straightforward However it requires manually scanning barcodes As a result errors are more likely to occur Command Programming The scanner can also be configured b...

Page 26: ...is an example that shows you the programming barcode and command for the Exit Setup function 1 The Exit Setup barcode 2 The Exit Setup command 3 The function feature that can be enabled by using the...

Page 27: ...scanner to enter the setup mode Then you can scan a number of programming barcodes to configure your scanner To exit the setup mode scan the Exit Setup barcode After scanning the Exit Setup barcode on...

Page 28: ...ry default settings You may need to reset your scanner cradle when 1 scanner cradle is not properly configured so that the scanner fails to decode barcodes or to communicate with cradle 2 you forget p...

Page 29: ...sful pairing Pair Cradle with Zigbee Router A cradle with its DIP switch see Fig 1 3 in the R position functions as a Zigbee router You can extend communication distance of the cradle by pairing multi...

Page 30: ...Enter Setup Exit Setup 20 Operating Mode Options Power Off Reboot Scanner Reboot Scanner...

Page 31: ...out Power off timeout specifies the amount of time the scanner remains in sleep mode before it powers off automatically Scan the barcode below to set this parameter 5 Minutes 10 Minutes 20 Minutes 30...

Page 32: ...provided to improve the lighting conditions during every image capture Normal Illumination LEDs are turned on only when scanner is reading barcode Always ON Illumination LEDs keep ON after scanner is...

Page 33: ...llows positioning the target barcode within its field of view and thus makes decoding easier Normal The scanner projects an aiming pattern only during barcode scanning capture Always ON Aiming pattern...

Page 34: ...p 24 Beep Good Read Beep Scan the appropriate barcode below to enable or disable the emission of beep when a non programming barcode is decoded Good Read Beep On Good Read Beep Off Good Read Beep Type...

Page 35: ...Enter Setup 25 Exit Setup Good Read Beep Volume Loud Low Medium Startup Beep Startup Beep On Startup Beep Off...

Page 36: ...nd the numeric barcodes corresponding to the ASCII values decimal of desired character s and then scan the Save barcode An NGR message can contain 0 7 characters ASCII value of character 0 255 Edit NG...

Page 37: ...de session continues during a scan attempt It is programmable in 1ms increments from 1ms to 3 600 000ms When it is set to 0 the timeout is infinite The default setting is 3 000ms Decode Session Timeou...

Page 38: ...Decodes Allow the scanner to re read same barcode The following parameter sets the timeout between decodes for same barcode It is programmable in 1ms increments from 0ms to 65 535ms The default setti...

Page 39: ...When the session ends the scanner continues to monitor ambient illumination Sense Mode Decode Session Timeout This parameter sets the maximum time decode session continues during a scan attempt It is...

Page 40: ...to 1 500ms 1 Scan the Enter Setup barcode 2 Scan the Image Stabilization Timeout barcode 3 Scan the numeric barcodes 1 5 0 and 0 See the Digit Barcodes in Appendix 4 Scan the Save barcode See the Save...

Page 41: ...Decodes Allow the scanner to re read same barcode Disable Timeout between Decodes Enable Timeout between Decodes The following parameter sets the timeout between decodes for same barcode It is progra...

Page 42: ...needs you may program the threshold value of illumination change Illumination changes that reaches or surpasses the predefined threshold value will cause the scanner to start a decode session The low...

Page 43: ...session continues during a scan attempt It is programmable in 1ms increments from 1ms to 3 600 000ms When it is set to 0 the timeout is infinite The default setting is 3 000ms Decode Session Timeout...

Page 44: ...es It is programmable in 1ms increments from 0ms to 65 535ms The default setting is 1 000ms Timeout between Decodes Set the Timeout between Decodes to 1 500ms 1 Scan the Enter Setup barcode 2 Scan the...

Page 45: ...quire the scanner information such as model number serial number manufacture date and firmware version The result will be sent to the Host Inquire All Information About Scanner Obtain Cradle Informati...

Page 46: ...6 Obtain FLASH Information To inquire the number of the barcodes stored in flash memory or empty the memory scan the appropriate barcode below Inquire the Number of Barcodes in Flash Memory Delete All...

Page 47: ...ood read if Zigbee is unavailable the transmission of decoded data cannot be accomplished Asynchronous Mode If Zigbee is available scanned data will be transferred to the cradle immediately after a go...

Page 48: ...eck data bit and stop bit to match the host device Baud rate is the number of bits of data transmitted per second Set the cradle s baud rate to match the Host requirements Otherwise data may not reach...

Page 49: ...Enter Setup 39 Exit Setup Parity Check By default the None option is enabled None Even Odd Stop Bit By default the 1 Stop Bit option is enabled 1 Stop Bit 2 Stop Bits...

Page 50: ...s disabled Disable Hardware Flow Control Enable Hardware Flow Control Before enabling hardware flow control make sure that RTS CTS signal line is contained in RS 232 cable Without the signal line RS 2...

Page 51: ...the Host via USB interface USB HID KBW and USB COM Port Emulation USB HID KBW USB HID KBW Examine KBW Connection By default the scanner examines whether KBW connection is available before data transmi...

Page 52: ...Enter Setup Exit Setup 42 USB Country Keyboard Types Keyboard layouts vary from country to country The default setting is U S keyboard U S Japanese Denmark Finland France Turkey F Italy Norway...

Page 53: ...Enter Setup 43 Exit Setup Spain Turkey Q UK Germany Belgium Russia Sweden Portugal...

Page 54: ...Enter Setup Exit Setup 44 Inter Keystroke Delay This parameter specifies the delay between emulated keystrokes No Delay 40ms 20ms 60ms 80ms...

Page 55: ...below to convert barcode data to your desired case No Case Conversion Convert All to Lower Case Convert All to Upper Case Invert Upper and Lower Case Characters When the Invert Upper and Lower Case C...

Page 56: ...elected keyboard type but falling into 0x20 0xFF are sent in the ALT Keypad way Mode 2 ASCII characters falling into 0x20 0xFF are sent in the ALT Keypad way Mode 3 All ASCII characters 0x00 0xFF are...

Page 57: ...tion characters 0x00 0x1F are sent as ASCII sequences over the keypad For more information see ASCII Function Key Mapping Table in Appendix Example Barcode data 0x16 Enable Function Key Mapping Ctrl V...

Page 58: ...ted as keystroke s on main keyboard To enable this feature scan the Emulate Numeric Keypad barcode Sending a number 0 9 is emulated as keystroke s on numeric keypad whereas sending other character lik...

Page 59: ...t in communication than keyboard emulation and traditional RS 232 interface Note USB HID POS does not require a custom driver However a HID interface on Windows 98 does All HID interfaces employ stand...

Page 60: ...s output report is used to send data to the device All programming commands can be used Bit Byte 7 6 5 4 3 2 1 0 0 Report ID 0x04 1 Length of the output data 2 63 Output data 1 62 VID PID USB uses VID...

Page 61: ...ecommended to disable those that are rarely used to improve the performance of the scanner Note Maximum barcode length supported by the scanner is 1024 bytes General Settings Disable All Symbologies I...

Page 62: ...ter Setup Exit Setup 52 Enable 1D Symbologies Enable 1D Symbologies Disable 1D Symbologies Disable 1D Symbologies Enable 2D Symbologies Enable 2D Symbologies Disable 2D Symbologies Disable 2D Symbolog...

Page 63: ...e and inverse barcode are shown below Regular Barcode Inverse Barcode Video Reverse is used to allow the scanner to read barcodes that are inverted Video Reverse ON Read both regular barcodes and inve...

Page 64: ...aults Restore the Factory Defaults of Code 128 Enable Disable Code 128 Enable Code 128 Disable Code 128 If the scanner fails to identify Code 128 barcodes you may first try this solution by scanning t...

Page 65: ...m length the scanner only decodes Code 128 barcodes with either the minimum or maximum length If minimum length is same as maximum length only Code 128 barcodes with that length are to be decoded Set...

Page 66: ...the Factory Defaults of EAN 8 Enable Disable EAN 8 Enable EAN 8 Disable EAN 8 Transmit Check Digit EAN 8 is 8 digits in length with the last one as its check digit used to verify the integrity of the...

Page 67: ...de Disable 2 Digit Add On Code Enable 2 Digit Add On Code Disable 5 Digit Add On Code Enable 5 Digit Add On Code Enable 2 Digit Add On Code Enable 5 Digit Add On Code The scanner decodes a mix of EAN...

Page 68: ...Required The scanner decodes a mix of EAN 8 barcodes with and without add on codes EAN 8 Add On Code Required EAN 8 Add On Code Not Required EAN 8 Extension Disable EAN 8 Zero Extend Transmit EAN 8 b...

Page 69: ...Exit Setup EAN 13 Restore Factory Defaults Restore the Factory Defaults of EAN 13 Enable Disable EAN 13 Enable EAN 13 Disable EAN 13 Transmit Check Digit Transmit EAN 13 Check Digit Do Not Transmit EA...

Page 70: ...e Disable 2 Digit Add On Code Enable 2 Digit Add On Code Disable 5 Digit Add On Code Enable 5 Digit Add On Code Enable 2 Digit Add On Code Enable 5 Digit Add On Code The scanner decodes a mix of EAN 1...

Page 71: ...Add On Code Required The scanner only decodes EAN 13 barcodes that contain add on codes EAN 13 Add On Code Not Required The scanner decodes a mix of EAN 13 barcodes with and without add on codes EAN 1...

Page 72: ...PC E If the scanner fails to identify UPC E barcodes you may first try this solution by scanning the Enter Setup barcode and then Enable UPC E barcode Transmit Check Digit UPC E is 8 digits in length...

Page 73: ...e Disable 2 Digit Add On Code Enable 2 Digit Add On Code Disable 5 Digit Add On Code Enable 5 Digit Add On Code Enable 2 Digit Add On Code Enable 5 Digit Add On Code The scanner decodes a mix of UPC E...

Page 74: ...dd on codes UPC E Add On Code Not Required The scanner decodes a mix of UPC E barcodes with and without add on codes UPC E Add On Code Required UPC E Add On Code Not Required Transmit System Character...

Page 75: ...up 65 Exit Setup UPC E Extension Disable UPC E Extend Transmit UPC E barcodes as is Enable UPC E Extend Extend UPC E barcodes to make them compatible in length to UPC A Disable UPC E Extend Enable UPC...

Page 76: ...PC A If the scanner fails to identify UPC A barcodes you may first try this solution by scanning the Enter Setup barcode and then Enable UPC A barcode Transmit Check Digit UPC A is 12 digits in length...

Page 77: ...e Disable 2 Digit Add On Code Enable 2 Digit Add On Code Disable 5 Digit Add On Code Enable 5 Digit Add On Code Enable 2 Digit Add On Code Enable 5 Digit Add On Code The scanner decodes a mix of UPC A...

Page 78: ...quired The scanner decodes a mix of UPC A barcodes with and without add on codes UPC A Add On Code Required UPC A Add On Code Not Required Transmit Preamble Character 0 The preamble character 0 is par...

Page 79: ...Defaults of Interleaved 2 of 5 Enable Disable Interleaved 2 of 5 Enable Interleaved 2 of 5 Disable Interleaved 2 of 5 If the scanner fails to identify Interleaved 2 of 5 barcodes you may first try th...

Page 80: ...gth the scanner only decodes Interleaved 2 of 5 barcodes with either the minimum or maximum length If minimum length is same as maximum length only Interleaved 2 of 5 barcodes with that length are to...

Page 81: ...ies with the check digit algorithm Barcodes passing the check will be transmitted whereas those failing it will not be transmitted Since Interleaved 2 of 5 must always have an even number of digits a...

Page 82: ...length of 14 characters and the last character as the check character Restore the Factory Defaults of ITF 14 Disable ITF 14 Enable ITF 14 But Do Not Transmit Check Digit Enable ITF 14 and Transmit Ch...

Page 83: ...a length of 6 characters and the last character as the check character Restore the Factory Defaults of ITF 6 Disable ITF 6 Enable ITF 6 But Do Not Transmit Check Digit Enable ITF 6 and Transmit Check...

Page 84: ...the Factory Defaults of Matrix 2 of 5 Enable Disable Matrix 2 of 5 Enable Matrix 2 of 5 Disable Matrix 2 of 5 If the scanner fails to identify Matrix 2 of 5 barcodes you may first try this solution b...

Page 85: ...length the scanner only decodes Matrix 2 of 5 barcodes with either the minimum or maximum length If minimum length is same as maximum length only Matrix 2 of 5 barcodes with that length are to be deco...

Page 86: ...lies with the check digit algorithm Barcodes passing the check will be transmitted whereas those failing it will not be transmitted Since Matrix 2 of 5 must always have an even number of digits a zero...

Page 87: ...de 39 barcodes you may first try this solution by scanning the Enter Setup barcode and then Enable Code 39 barcode Transmit Start Stop Character Code 39 uses an asterisk for both the start and the sto...

Page 88: ...um length the scanner only decodes Code 39 barcodes with either the minimum or maximum length If minimum length is same as maximum length only Code 39 barcodes with that length are to be decoded Set t...

Page 89: ...ter Verification The scanner checks the integrity of all Code 39 barcodes to verify that the data complies with the check digit algorithm Barcodes passing the check will be transmitted whereas those f...

Page 90: ...tup Exit Setup 80 Enable Disable Code 39 Full ASCII The scanner can be configured to identify all ASCII characters by scanning the appropriate barcode below Disable Code 39 Full ASCII Enable Code 39 F...

Page 91: ...efaults Restore the Factory Defaults of Codabar Enable Disable Codabar Enable Codabar Disable Codabar If the scanner fails to identify Codabar barcodes you may first try this solution by scanning the...

Page 92: ...um length the scanner only decodes Codabar barcodes with either the minimum or maximum length If minimum length is same as maximum length only Codabar barcodes with that length are to be decoded Set t...

Page 93: ...ter Verification The scanner checks the integrity of all Codabar barcodes to verify that the data complies with the check digit algorithm Barcodes passing the check will be transmitted whereas those f...

Page 94: ...her or not to transmit the start stop characters by scanning the appropriate barcode below Transmit Start Stop Character Do Not Transmit Start Stop Character ABCD ABCD as the Start Stop Character Star...

Page 95: ...efaults Restore the Factory Defaults of Code 93 Enable Disable Code 93 Enable Code 93 Disable Code 93 If the scanner fails to identify Code 93 barcodes you may first try this solution by scanning the...

Page 96: ...um length the scanner only decodes Code 93 barcodes with either the minimum or maximum length If minimum length is same as maximum length only Code 93 barcodes with that length are to be decoded Set t...

Page 97: ...After Verification The scanner checks the integrity of all Code 93 barcodes to verify that the data complies with the check digit algorithm Barcodes passing the checks will be transmitted whereas thos...

Page 98: ...store the Factory Defaults of UCC EAN 128 Enable Disable UCC EAN 128 Enable UCC EAN 128 Disable UCC EAN 128 If the scanner fails to identify UCC EAN 128 barcodes you may first try this solution by sca...

Page 99: ...length the scanner only decodes UCC EAN 128 barcodes with either the minimum or maximum length If minimum length is same as maximum length only UCC EAN 128 barcodes with that length are to be decoded...

Page 100: ...GS1 Databar Enable GS1 Databar Disable GS1 Databar If the scanner fails to identify GS1 Databar barcodes you may first try this solution by scanning the Enter Setup barcode and then Enable GS1 Databa...

Page 101: ...efaults Restore the Factory Defaults of Code 11 Enable Disable Code 11 Enable Code 11 Disable Code 11 If the scanner fails to identify Code 11 barcodes you may first try this solution by scanning the...

Page 102: ...um length the scanner only decodes Code 11 barcodes with either the minimum or maximum length If minimum length is same as maximum length only Code 11 barcodes with that length are to be decoded Set t...

Page 103: ...OD11 Len 10 Two Check Digits MOD11 MOD9 Len 10 Two Check Digits MOD11 MOD11 Do Not Transmit Check Digit Two Check Digits MOD11 MOD9 Transmit Check Digit If you select a check digit algorithm and the D...

Page 104: ...Restore the Factory Defaults of ISBN Enable Disable ISBN Enable ISBN Disable ISBN If the scanner fails to identify ISBN barcodes you may first try this solution by scanning the Enter Setup barcode and...

Page 105: ...igit Add On Code Disable 5 Digit Add On Code Enable 2 Digit Add On Code Enable 5 Digit Add On Code The scanner decodes a mix of ISBN barcodes with and without 2 digit 5 digit add on codes Disable 2 Di...

Page 106: ...SBN Add On Code Required The scanner only decodes ISBN barcodes that contain add on codes ISBN Add On Code Not Required The scanner decodes a mix of ISBN barcodes with and without add on codes ISBN Ad...

Page 107: ...actory Defaults Restore the Factory Defaults of ISSN Enable Disable ISSN Enable ISSN Disable ISSN If the scanner fails to identify ISSN barcodes you may first try this solution by scanning the Enter S...

Page 108: ...igit Add On Code Disable 5 Digit Add On Code Enable 2 Digit Add On Code Enable 5 Digit Add On Code The scanner decodes a mix of ISSN barcodes with and without 2 digit 5 digit add on codes Disable 2 Di...

Page 109: ...SSN Add On Code Required The scanner only decodes ISSN barcodes that contain add on codes ISSN Add On Code Not Required The scanner decodes a mix of ISSN barcodes with and without add on codes ISSN Ad...

Page 110: ...Defaults Restore the Factory Defaults of AIM 128 Enable Disable AIM 128 Enable AIM 128 Disable AIM 128 If the scanner fails to identify AIM 128 barcodes you may first try this solution by scanning the...

Page 111: ...um length the scanner only decodes AIM 128 barcodes with either the minimum or maximum length If minimum length is same as maximum length only AIM 128 barcodes with that length are to be decoded Set t...

Page 112: ...e the Factory Defaults of Industrial 25 Enable Disable Industrial 25 Enable Industrial 25 Disable Industrial 25 If the scanner fails to identify Industrial 25 barcodes you may first try this solution...

Page 113: ...length the scanner only decodes Industrial 25 barcodes with either the minimum or maximum length If minimum length is same as maximum length only Industrial 25 barcodes with that length are to be deco...

Page 114: ...fter Verification The scanner checks the integrity of all Industrial 25 barcodes to verify that the data complies with the check digit algorithm Barcodes passing the check will be transmitted whereas...

Page 115: ...estore the Factory Defaults of Standard 25 Enable Disable Standard 25 Enable Standard 25 Disable Standard 25 If the scanner fails to identify Standard 25 barcodes you may first try this solution by sc...

Page 116: ...length the scanner only decodes Standard 25 barcodes with either the minimum or maximum length If minimum length is same as maximum length only Standard 25 barcodes with that length are to be decoded...

Page 117: ...fter Verification The scanner checks the integrity of all Standard 25 barcodes to verify that the data complies with the check digit algorithm Barcodes passing the check will be transmitted whereas th...

Page 118: ...Defaults Restore the Factory Defaults of Plessey Enable Disable Plessey Enable Plessey Disable Plessey If the scanner fails to identify Plessey barcodes you may first try this solution by scanning the...

Page 119: ...um length the scanner only decodes Plessey barcodes with either the minimum or maximum length If minimum length is same as maximum length only Plessey barcodes with that length are to be decoded Set t...

Page 120: ...git After Verification The scanner checks the integrity of all Plessey barcodes to verify that the data complies with the check digit algorithm Barcodes passing the checks will be transmitted whereas...

Page 121: ...estore the Factory Defaults of MSI Plessey Enable Disable MSI Plessey Enable MSI Plessey Disable MSI Plessey If the scanner fails to identify MSI Plessey barcodes you may first try this solution by sc...

Page 122: ...length the scanner only decodes MSI Plessey barcodes with either the minimum or maximum length If minimum length is same as maximum length only MSI Plessey barcodes with that length are to be decoded...

Page 123: ...igit MOD10 Do Not Transmit Check Digit Two Check Digits MOD10 MOD10 Transmit Check Digit If you select a check digit algorithm and the Do Not Transmit Check Digit option MSI Plessey barcodes with a le...

Page 124: ...y Defaults Restore the Factory Defaults of PDF417 Enable Disable PDF417 Enable PDF417 Disable PDF417 If the scanner fails to identify PDF417 barcodes you may first try this solution by scanning the En...

Page 125: ...ot allowed to be greater than maximum length If you only want to read PDF417 barcodes with a specific length set both minimum and maximum lengths to be that desired length Set the scanner to decode PD...

Page 126: ...Defaults Restore the Factory Defaults of QR Code Enable Disable QR Code Enable QR Code Disable QR Code If the scanner fails to identify QR Code barcodes you may first try this solution by scanning the...

Page 127: ...ot allowed to be greater than maximum length If you only want to read QR Code barcodes with a specific length set both minimum and maximum lengths to be that desired length Set the scanner to decode Q...

Page 128: ...Enter Setup Exit Setup 118 Micro QR Enable Micro QR Disable Micro QR...

Page 129: ...estore the Factory Defaults of Data Matrix Enable Disable Data Matrix Enable Data Matrix Disable Data Matrix If the scanner fails to identify Data Matrix barcodes you may first try this solution by sc...

Page 130: ...ot allowed to be greater than maximum length If you only want to read Data Matrix barcodes with a specific length set both minimum and maximum lengths to be that desired length Set the scanner to deco...

Page 131: ...rcodes having the same amount of modules in length and width 10 10 12 12 144 144 Rectangular barcodes having different amounts of models in length and width 6 16 6 14 14 22 Enable Rectangular Barcode...

Page 132: ...ters and other multi byte characters However in real applications they do not and should not have all information we need such as barcode type data acquisition time and delimiter in order to keep the...

Page 133: ...with no prefix suffix Enable All Prefix Suffix Allow user to append Code ID prefix AIM ID prefix custom prefix suffix and terminating character to the barcode data before the transmission Disable All...

Page 134: ...Custom Prefix barcode and then the numeric barcodes corresponding to the hexadecimal value of a desired prefix To save the settings scan the Save barcode Note A custom prefix cannot exceed 10 charact...

Page 135: ...x is enabled the scanner will add the symbology identifier before the scanned data after decoding Disable AIM ID Prefix Enable AIM ID Prefix AIM ID is not user programmable Code ID Prefix Code ID can...

Page 136: ...l symbologies Modify PDF417 Code ID to be p its hexadecimal value is 0x70 1 Scan the Enter Setup barcode 2 Scan the Modify PDF417 Code ID barcode 3 Scan the numeric barcodes 7 and 0 See the Digit Barc...

Page 137: ...nter Setup 127 Exit Setup Modify PDF417 Code ID Modify Data Matrix Code ID Modify QR Code ID Modify Matrix 25 Code ID Modify ISSN Code ID Modify AIM 128 Code ID Modify EAN 8 Code ID Modify ITF 6 Code...

Page 138: ...tup Exit Setup 128 Modify EAN 13 Code ID Modify Code 39 Code ID Modify UPC E Code ID Modify Codabar Code ID Modify UPC A Code ID Modify Code 93 Code ID Modify Interleaved 2 of 5 Code ID Modify Code 12...

Page 139: ...p Modify ITF 14 Code ID Modify ISBN Code ID Modify UCC EAN 128 Code ID Modify Industrial 25 Code ID Modify Code 11 Code ID Modify Standard 25 Code ID Modify Plessey Code ID Modify MSI Plessey Code ID...

Page 140: ...Custom Suffix barcode and then the numeric barcodes corresponding to the hexadecimal value of a desired suffix To save the settings scan the Save barcode Note A custom suffix cannot exceed 10 charact...

Page 141: ...CRLF can only be used to mark the end of data which means nothing can be added after it Disable Terminating Character Suffix Enable Terminating Character Suffix Set Terminating Character Suffix The s...

Page 142: ...I Table in Appendix for hexadecimal values of terminating characters Note A terminating character suffix cannot exceed 2 characters Set Terminating Character Suffix Set the terminating character suffi...

Page 143: ...indoor illuminance is around 1 000 lux while outdoor illuminance may reach 60 000 lux or even over 100 000 lux Two options are provided for ambient illumination settings Normal Illuminance applicable...

Page 144: ...134 Appendix Digit Barcodes After scanning numeric barcode s you need to scan the Save barcode to save the data 0 5 0 1 2 3 4 5...

Page 145: ...135 6 9 6 7 8 9...

Page 146: ...136 A F A B C D E F...

Page 147: ...git barcode and then the correct digit or scan the Delete All Digits barcode and then the digits you want For instance after reading the Maximum Length barcode and numeric barcodes 1 2 and 3 you scan...

Page 148: ...ode Sense mode and Continuous mode 1 3 600 000ms 0 Infinite Timeout between Decodes Same Barcode Disabled 1 500ms 0 65 535ms Sense Mode Decode Session Timeout 3 000ms Applicable to Trigger mode Sense...

Page 149: ...on Enabled USB Country Keyboard Type U S Inter Keystroke Delay No delay Convert Case No conversion Emulate ALT Keypad Disabled Function Key Mapping Disabled Emulate Numeric Keypad Disabled Prefix Suff...

Page 150: ...128 AIM 128 Enabled Maximum Length 127 Minimum Length 1 EAN 8 EAN 8 Enabled Check Digit Transmit 2 Digit Add On Code Disabled 5 Digit Add On Code Disabled Add On Code Not required Extend to EAN 13 Di...

Page 151: ...Disabled Add On Code Not required Extend to UPC A Disabled System Character 0 Do not transmit UPC A UPC A Enabled Check Digit Transmit 2 Digit Add On Code Disabled 5 Digit Add On Code Disabled Add On...

Page 152: ...Industrial 2 of 5 Enabled Check Digit Verification Disabled Check Digit Do not transmit Maximum Length 127 Minimum Length 6 Standard 2 of 5 Standard 2 of 5 Enabled Check Digit Verification Disabled Ch...

Page 153: ...93 Code 93 Enabled Check Digit Verification Enabled Check Digit Do not transmit Maximum Length 127 Minimum Length 3 GS1 Databar GS1 Databar Enabled Application Identifier 01 Transmit Code 11 Code 11 E...

Page 154: ...heck Digit Do not transmit Maximum Length 127 Minimum Length 2 PDF 417 PDF 417 Enabled Maximum Length 1024 Minimum Length 1 QR Code QR Code Enabled Micro QR Enabled Maximum Length 1024 Minimum Length...

Page 155: ...I1 Transmit check digit after verification I3 Do not transmit check digit after verification ITF 6 I1 Transmit check digit I3 Do not transmit check digit ITF 14 I1 Transmit check digit I3 Do not trans...

Page 156: ...0 do not transmit check digit M8 Two check digits M9 No check digit verification Matrix 2 of 5 X0 Specified by the manufacturer X1 No check digit verification X2 One check digit MOD10 transmit check d...

Page 157: ...2005 ECI included FNC1 is the 1st character after the start character Q5 QR Code 2005 ECI excluded FNC1 is the 2nd character after the start character Q6 QR Code 2005 ECI included FNC1 is the 2nd char...

Page 158: ...AIM 128 f EAN 8 d EAN 13 d ISSN n ISBN B UPC E c UPC A c Interleaved 2 of 5 e ITF 6 e ITF 14 e Matrix 2 of 5 v Industrial 2 of 5 D Standard 2 of 5 s Code 39 b Codabar a Code 93 i Code 11 H Plessey p...

Page 159: ...11 VT Vertical Tab 0c 12 FF Form Feed 0d 13 CR Carriage Return 0e 14 SO Shift Out 0f 15 SI Shift In 10 16 DLE Data Link Escape 11 17 DC1 XON Device Control 1 12 18 DC2 Device Control 2 13 19 DC3 XOFF...

Page 160: ...llar Sign 25 37 Percent 26 38 Ampersand 27 39 Single Quote 28 40 Right Closing Parenthesis 29 41 Right Closing Parenthesis 2a 42 Asterisk 2b 43 Plus 2c 44 Comma 2d 45 Minus Dash 2e 46 Dot 2f 47 Forwar...

Page 161: ...5 A 42 66 B 43 67 C 44 68 D 45 69 E 46 70 F 47 71 G 48 72 H 49 73 I 4a 74 J 4b 75 K 4c 76 L 4d 77 M 4e 78 N 4f 79 O 50 80 P 51 81 Q 52 82 R 53 83 S 54 84 T 55 85 U 56 86 V 57 87 W 58 88 X 59 89 Y 5a 9...

Page 162: ...0 d 65 101 e 66 102 f 67 103 g 68 104 h 69 105 i 6a 106 j 6b 107 k 6c 108 l 6d 109 m 6e 110 n 6f 111 o 70 112 p 71 113 q 72 114 r 73 115 s 74 116 t 75 117 u 76 118 v 77 119 w 78 120 x 79 121 y 7a 122...

Page 163: ...rtical Tab 0B Vertical Tab Ctrl K FF Form Feed 0C Backspace Crtl L CR Carriage Return 0D Enter Ctrl M SO Shift Out 0E Insert Ctrl N SI Shift In 0F Esc Ctrl O DLE Data Link Escape 10 F11 Ctrl P DC1 XON...

Page 164: ...B 1C 1D 1E 1F United States Ctrl Ctrl Ctrl Ctrl 6 Ctrl Belgium Ctrl Ctrl Ctrl Ctrl 6 Ctrl Scandinavia Ctrl 8 Ctrl Ctrl 9 Ctrl 6 Ctrl France Ctrl Ctrl 8 Ctrl Ctrl 6 Ctrl Germany Ctrl Ctrl Ctrl 6 Ctrl I...

Page 165: ...TEL 31 0 345 87 00 33 FAX 31 0 345 87 00 39 Email info newland id com WEB www newland id com Tech Support tech support newland id com Newland North America Inc Address 46559 Fremont Blvd Fremont CA 9...

Reviews: