Enter Setup
】
49
**
【
Exit Setup
】
USB COM Port Emulation
To use this feature, a driver is required.
【
USB COM Port Emulation
】
USB HID-POS
Introduction
The USB HID-POS interface is recommended for new application programs. It can send up to 56
characters in a single USB report and appears more efficient than keyboard emulation.
Features:
HID based, no custom driver required.
Way more efficient in communication than keyboard emulation and traditional RS-232 interface.
Note:
USB HID-POS does not require a custom driver. However, a HID interface on Windows 98 does.
All HID interfaces employ standard driver provided by the operating system. Use defaults when installing
the driver.
【
USB HID-POS
】
Access the Scanner with Your Program
Use CreateFile to access the scanner as a HID device and then use ReadFile to deliver the scanned data
to the application program. Use WriteFile to send data to the scanner.
For detailed information about USB and HID interfaces, go to