TROUBLE SHOOTING GUIDE
SYMPTOM
POSSIBLE CAUSE
WHAT TO CHECK
REMEDY
WEAK COFFEE
1. Filters
2. Not siphoning properly
3. Improper loading of brew
basket
1. Are the correct filters being
used?
2. Refer to “Dripping” step 1
3. Filter & coffee in brew
basket
1. Insert correct filter
2. Refer to “DRIPPING” step 1
3. Filter centered, coffee bed
level
COLD WARMER STATION
1. Warmer – defective
2. Warmer ON/OFF switch
3. Bad harness
1. Voltage at warmer terminals
should be 120V AC
2. If voltage is not present on
warmer terminals check
continuity of switch
3. Check connections between
harness & switch, and
between switch & warmer
1. If voltage is present on
terminals, but warmer will
not heat, replace warmer
2. If switch does not make &
break continuity when
turned off, replace switch
3. All connections should be
tight
CONDENSATION ON THE
INSIDE OF CABINET
1. Tank lid gasket
2. Spray head tube assy.
3. Thermostat grommet
4. Receiving pan nut
5. Main thermostat set above
201°F
1. Nicks or cuts in the gasket
2. Tightness of assembly to lid
3. Tight fit, nicks, or cuts
4. Receiving pan nut loose
5. Check thermostat
calibration
1. Replace gasket
2. Tighten spray head tube
assy. to tank lid
3. Adjust or replace grommet
4. Tighten nut
5. Calibrate or replace
thermostat
WATER KEEPS RUNNING
1. 1.Solenoid Valve
2. Start Switch
3. Timer
1. Refer to “DRIPPING” step 1
2. Remove wires from switch
& check continuity
3. Solid state timers are not
repairable, if timer will not
shut off, replace timer
1. Refer to “DRIPPING” step 1
2. If start switch does not
make or break contact,
switch should be replaced
3. Replace timer