9
PROGRAMMING AND CALIBRATION CONT’D
CALIBRATION*
:
(NON-FLOWMETER MACHINES ONLY)
This entry shows the amount of
water the brewer dispenses in 30 seconds with no pauses. To run calibration, place a container
able to hold at least 10 oz preferably greater. Press button D (see Fig 1) and the brewer will enter
a brew cycle. The door will open to allow the user to place a beverage pod in the drawer. After
the pod has been placed press the button D button (see Fig 1) again to start the brew cycle.
After the cycle has completed, measure the amount of water dispensed and adjust the
Calibration number shown in tenths of an ounce to match the amount dispensed by using
button A and button B (see Fig 1) to increment or decrement by one. Press the Reset key (see
Fig 1) to advance to the brew button programming selections. Range for the calibration volume
is 10 to 320 tenths of an ounce. The default is 100 tenths of an ounce.
BUTTON SET UP
:
This entry takes the user into a sub menu to program the parameters
unique to each key. When this entry is accessed the display will change to SELECT BUTTON
indicating that the user should press the brew key (button B, C or D (see Fig 1)) to be
programmed. When a brew key is selected the display will show the first entry in the Button Set
up sub menu, PRE-INFUSION. While SELECT BUTTON is displayed the user may exit back to the
Main menu by pressing the Reset key (see Fig 1).
With these four entries in the BUTTON SET UP sub menu:
PRE-INFUSION
:
This entry sets the time of the pre-infusion pulse of water in tenths of a
second. Range is 1 to 30, the default is 15 tenths of a seconds.
BREW VOLUME
:
This entry sets the volume in tenths of an ounce for this key to dispense.
The Range is from 20 to 160 tenths of an ounce with the default set to 70 tenths of an ounce
BREW TIME
:
This entry sets the brew time in seconds for a 7-ounce cup of coffee with
on/off pulses. The range is from ~30 to 99 seconds with the default being 35 seconds.
RETURN
:
Exit to Main Programming Menu.
FILTER SELECT
:
This entry allows the user to select the filter size for the filter used on the
inlet for the water. Choices include OFF, 500 GAL, 1000 GAL and 1500 GAL. These set the
counter for the filter warning. Whenever water is dispensed the counter is incremented to
account for the water dispensed. When the counter is above 90% of the capacity of the chosen
filter a warning message, “REPLACE WATER FILTER”, is displayed in place of the “READY”
message. To reset the counter the user must enter the programming menu and enter the RESET
FILTER entry described below. The following entries are only shown when a filter is selected. If
the filter selection is OFF then following entries are not available. Press the Reset key (see Fig 1)
to leave the entry and return to the Main Programming menu.
FILTER REMAINING
:
This entry scrolls the number of Gallons left before the filter should be
replaced. Press the Reset key (see Fig 1) to leave the entry and return to the Main Programming
menu.
RESET FILTER
:
When in this entry the message “PRESS OPEN TO RESET’. Press the Open
Door key will reset the Filter Use counter to the value chosen in the FILTER SELECT entry
above. Press the Reset key (see Fig 1) to leave the entry and return to the Main Programming
menu.