background image

 

9

 

PROGRAMMING AND CALIBRATION CONT’D 

CALIBRATION*

:

 (NON-FLOWMETER MACHINES ONLY)

 This entry shows the amount of 

water the brewer dispenses in 30 seconds with no pauses. To run calibration, place a container 
able to hold at least 10 oz preferably greater. Press button D (see Fig 1) and the brewer will enter 
a brew cycle. The door will open to allow the user to place a beverage pod in the drawer. After 
the pod has been placed press the button D button (see Fig 1) again to start the brew cycle.  

After the cycle has completed, measure the amount of water dispensed and adjust the 
Calibration number shown in tenths of an ounce to match the amount dispensed by using 
button A and button B (see Fig 1) to increment or decrement by one. Press the Reset key (see 
Fig 1) to advance to the brew button programming selections. Range for the calibration volume 
is 10 to 320 tenths of an ounce. The default is 100 tenths of an ounce. 

 

 

BUTTON SET UP

:

 This entry takes the user into a sub menu to program the parameters 

unique to each key. When this entry is accessed the display will change to SELECT BUTTON 
indicating that the user should press the brew key (button B, C or D (see Fig 1)) to be 
programmed. When a brew key is selected the display will show the first entry in the Button Set 
up sub menu, PRE-INFUSION. While SELECT BUTTON is displayed the user may exit back to the 
Main menu by pressing the Reset key (see Fig 1). 

With these four entries in the BUTTON SET UP sub menu: 

PRE-INFUSION

:

 This entry sets the time of the pre-infusion pulse of water in tenths of a 

second. Range is 1 to 30, the default is 15 tenths of a seconds. 

BREW VOLUME

:

 This entry sets the volume in tenths of an ounce for this key to dispense. 

The Range is from 20 to 160 tenths of an ounce with the default set to 70 tenths of an ounce 

BREW TIME

:

 This entry sets the brew time in seconds for a 7-ounce cup of coffee with 

on/off pulses. The range is from ~30 to 99 seconds with the default being 35 seconds. 

RETURN

:

 Exit to Main Programming Menu. 

FILTER SELECT

:

 This entry allows the user to select the filter size for the filter used on the 

inlet for the water. Choices include OFF, 500 GAL, 1000 GAL and 1500 GAL. These set the 
counter for the filter warning. Whenever water is dispensed the counter is incremented to 
account for the water dispensed. When the counter is above 90% of the capacity of the chosen 
filter a warning message, “REPLACE WATER FILTER”, is displayed in place of the “READY” 
message. To reset the counter the user must enter the programming menu and enter the RESET 
FILTER entry described below. The following entries are only shown when a filter is selected. If 
the filter selection is OFF then following entries are not available. Press the Reset key (see Fig 1) 
to leave the entry and return to the Main Programming menu. 

FILTER REMAINING

:

 This entry scrolls the number of Gallons left before the filter should be 

replaced. Press the Reset key (see Fig 1) to leave the entry and return to the Main Programming 
menu. 

RESET FILTER

:

 When in this entry the message “PRESS OPEN TO RESET’. Press the Open 

Door key will reset the Filter Use counter to the value chosen in the FILTER SELECT entry 
above. Press the Reset key (see Fig 1) to leave the entry and return to the Main Programming 
menu. 

END

 – Exit to Main and save parameters. 

Summary of Contents for Fresh Cup

Page 1: ...ES INC 3650 NEW TOWN BLVD SAINT CHARLES MO 63301 1 800 325 7867 FAX 1 636 925 0029 Features Specifications AUTOMATIC POD REMOVAL FLOWMETER OPTION 20 OZ TRAVEL MUG LARGE POD WASTE TRAY THRU COUNTER OPT...

Page 2: ...PRODUCT WARRANTY 4 MACHINE SET UP 5 MACHINE OPERATION 6 MACHINE PROGRAMMING CALIBRATION 7 SERVICING THE MACHINE 11 TANK REMOVAL 12 POD BREWING MECHANISM 13 ELECTRICAL COMPONENTS 17 ERROR MESSAGES 18 F...

Page 3: ...1700W 120V CANADA 1400W 120V INTERNATIONAL 1700W 220V TANK CAPACITY 1 US GALLON DRIP TRAY CAPACITY 8 OUNCES POD WASTE TRAY CAPACITY 80 PODS USE WASTE TRAY PN 780306 FOR THRU COUNTER USE UP TO 20 OZ C...

Page 4: ...ANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE The agents dealers or employees of Newco are not authorized to make modifications to this warranty or to make additional warranties that are binding on N...

Page 5: ...t run use 1 4 tubing and connect to 1 2 or larger water line The inlet water fitting on the back of the brewer is a 1 4 flare fitting It may be necessary to remove the plumbing cover box on the rear o...

Page 6: ...R BEEPER CAN BE SHUT OFF AIR PUMP POD DRYING TIME PUMP STRENGTH CAN BE ADJUSTED POD COUNT TO EMPTY POD WASTE BIN AJDUSTABLE OR CAN BE TURNED OFF IF USING THROUGH THE COUNTER WASTE BIN COFFEE OR TEA PR...

Page 7: ...43 to 44 will alter the dispensed volume by approx 0 2 oz for a 7oz dispense If you want more in your cup decrease the number and if you want less in your cup increase the number Example 43 to 44 will...

Page 8: ...Power Save function has been turned off This entry sets the time the machine will operate normally until the power save function is activated The user can choose 1 through 4 hours in 1 hour increment...

Page 9: ...of a second Range is 1 to 30 the default is 15 tenths of a seconds BREW VOLUME This entry sets the volume in tenths of an ounce for this key to dispense The Range is from 20 to 160 tenths of an ounce...

Page 10: ...d to fine tune the amount of liquid that is dispensed The default value is 43 CYCLE COUNT This entry shows the number of brew cycles that has occurred on this machine since the last time the count was...

Page 11: ...OD WASTE TRAY CAUTION UNLESS THE TANK IS LEFT TO COOL THE WATER IS EXTREMELY HOT AND CAN CUASE HARMFUL BURNS REPLACE DRAIN PLUG ENSURE HOSE CLAMP IS TIGHT AND REPOSITION DRAIN HOSE BEFORE RE FILLING T...

Page 12: ...BOARD BRACKET OUT OF MACHINE TO ACCESS TRANSFORMER REMOVE 3 8 32 NUTS TO PREPARE TANK FOR REMOVAL TWO ON TOP OF TANK ONE ON BOTTOM OF PUMP BRACKET REMOVE 2 6 32 SCREWS TO REMOVE SIDE PANEL FOR PUMP A...

Page 13: ...13 POD BREWING MECHANISM 780234 61MM and 780330 56MM...

Page 14: ...TEM NEWCO PN DESCRIPTION QTY EA 1 780230 BREW MECH MOTOR 2 2 780231 DELTROL SOLENOID 1 3 780257 780329 UPPER BREW CHAMBER 61MM UPPER BREW CHAMBER 56MM 1 4 773246 U CUP SEAL RING 1 5 780262 780314 LOWE...

Page 15: ...15 780234 TANK ASS Y 1 10 2 3 4 5 6 7 8 9...

Page 16: ...T 30A 1 2 111593 HI LIMIT THERMOSTAT 1 3 706341 PUMP ASS Y 120 VOLT 1 4 781772 PUMP ASS Y W ELBOW 1 5 780253 PUNCHED TANK W STUD 1 6 773056 AIR PUMP POD 1 7 108022 LIQUID LEVEL PROBE 1 8 151677 DUAL T...

Page 17: ...17 ELECTRICAL COMPONENTS...

Page 18: ...TH LOW WATER LEVEL CHECK FILL VALVE OR WATER SUPPLY LINE Message UPPER LOWER MOTOR ERROR BREW CHAMBER DRIVE MOTOR ERROR CHECK FOR JAM OR OBSTRUCTION IN BREW CHAMBER Message BOARD ERROR CONTROL BOARD W...

Page 19: ...FLOW ADJUSTMENT CONTROL VIEW FROM TOP OF MACHINE COVER REMOVED ONLY USED FOR ADJUSTING WATER FLOW RATE FACTORY SET CALIBRATION PUMP FLOW ADJUSTMENT CLOCKWISE DECREASE FLOW COUNTER CLOCKWISE INCREASE F...

Page 20: ...3 2 1 2 1 4 3 COFFEE PUMP FILL SOLENOID BK WH BK WH BR BK WH BR YL VIO BK VIO WH VIO BK VIO BK BK BK BK BK VIO BK VIO BK WH WH GY GY GY GY OR GY BK RD OR GY RD BK WH WH BK YL BR BR WH GY BR RD RD RD...

Page 21: ...21...

Page 22: ...22...

Reviews: