8
PROGRAMMING AND CALIBRATION CONT’D
TEMPERATURE
:
In this entry the user may set the tank temperature in the range of 170 to 205
degrees Fahrenheit with the default at 200 degrees F. Pressing button D (see Fig 1) will toggle
the display so the user may view the real tank temperature. The real temperature display has all
three decimal points illuminated. Pressing button D (see Fig 1) again will switch the display back
to show the current set point. As with most of the entries, button A and button B (see Fig 1) will
change the set point, incrementing or decrementing by one. Pressing Reset key (see Fig 1) will
exit.
POWER SAVE
:
This entry allows the user to select the Power Save mode. Use button A and
button B (see Fig 1) to change the entry then press the Reset key to exit.
Off (default) – Turns Power Save function off.
Prt – Partial Power Save Mode. After the user selectable time out the tank temperature set
point is set to 180 until a key is pressed. When this mode is selected the right most decimal
point in the display is on.
FuL – Full Power Save Mode. After the user selectable time out the tank heater is disabled
until a key is pressed. When this mode is selected the left most decimal point in the display
is on.
POWER SAVE TIME:
This entry will not be displayed if the Power Save function
has been turned off. This entry sets the time the machine will operate normally
until the power save function is activated. The user can choose 1 through 4 hours
in 1-hour increments with the default set to 4 hours. As with most of the entries,
button A and button B (see Fig 1) will change the time, incrementing or
decrementing by one. Pressing Reset key (see Fig 1) will exit.
BEEPER VOLUME
:
The range is from 1 to 24. The default is 13.
AIR PUMP SPEED
:
In this entry the user may set the air pump strength in the range of 5 to 10
strength with the default at 9. As with most of the entries button A and button B (see Fig 1) will
change the Air Pump Strength, incrementing or decrementing by one. Pressing Reset (see Fig 1)
key will exit.
AIR PUMP TIME
:
In this entry the user may set the air pump time in the range of 2 to 10
seconds with the default at 5. As with most of the entries button A and button B (see Fig 1) will
change the Air Pump Time, incrementing or decrementing by one. Pressing Reset (see Fig 1)
key will exit.
POD COUNT
: In this entry the user may set the number of pods the brewer will hold before
signaling that the bin is full. The range is 10 to 100 pods, with the default at 40. Setting the pod
count under 10 turns off the count so the bin full alarm will never go off. As with most of the
entries button A and button B (see Fig 1) will change the Pod Count threshold, incrementing or
decrementing by one. Pressing Reset key (see Fig 1) will exit.