SPECIFICATIONS 

 

TANK WATTAGES 

US 1700W 120V- CANADA 1400W 120V- INTERNATIONAL 1700W 220V 

 

TANK CAPACITY-1 US GALLON 

 

 

DRIP TRAY CAPACITY 8 OUNCES 

 
 

POD WASTE TRAY CAPACITY 80 PODS-

USE WASTE TRAY 

PN

  

780306 FOR THRU-COUNTER USE 

 

UP TO 20 OZ CUP SIZE

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

SHIPPING  WT-APPROX 35 LBS

 

Summary of Contents for Fresh Cup

Page 1: ...ES INC 3650 NEW TOWN BLVD SAINT CHARLES MO 63301 1 800 325 7867 FAX 1 636 925 0029 Features Specifications AUTOMATIC POD REMOVAL FLOWMETER OPTION 20 OZ TRAVEL MUG LARGE POD WASTE TRAY THRU COUNTER OPT...

Page 2: ...PRODUCT WARRANTY 4 MACHINE SET UP 5 MACHINE OPERATION 6 MACHINE PROGRAMMING CALIBRATION 7 SERVICING THE MACHINE 11 TANK REMOVAL 12 POD BREWING MECHANISM 13 ELECTRICAL COMPONENTS 17 ERROR MESSAGES 18 F...

Page 3: ...1700W 120V CANADA 1400W 120V INTERNATIONAL 1700W 220V TANK CAPACITY 1 US GALLON DRIP TRAY CAPACITY 8 OUNCES POD WASTE TRAY CAPACITY 80 PODS USE WASTE TRAY PN 780306 FOR THRU COUNTER USE UP TO 20 OZ C...

Page 4: ...ANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE The agents dealers or employees of Newco are not authorized to make modifications to this warranty or to make additional warranties that are binding on N...

Page 5: ...t run use 1 4 tubing and connect to 1 2 or larger water line The inlet water fitting on the back of the brewer is a 1 4 flare fitting It may be necessary to remove the plumbing cover box on the rear o...

Page 6: ...R BEEPER CAN BE SHUT OFF AIR PUMP POD DRYING TIME PUMP STRENGTH CAN BE ADJUSTED POD COUNT TO EMPTY POD WASTE BIN AJDUSTABLE OR CAN BE TURNED OFF IF USING THROUGH THE COUNTER WASTE BIN COFFEE OR TEA PR...

Page 7: ...43 to 44 will alter the dispensed volume by approx 0 2 oz for a 7oz dispense If you want more in your cup decrease the number and if you want less in your cup increase the number Example 43 to 44 will...

Page 8: ...Power Save function has been turned off This entry sets the time the machine will operate normally until the power save function is activated The user can choose 1 through 4 hours in 1 hour increment...

Page 9: ...of a second Range is 1 to 30 the default is 15 tenths of a seconds BREW VOLUME This entry sets the volume in tenths of an ounce for this key to dispense The Range is from 20 to 160 tenths of an ounce...

Page 10: ...d to fine tune the amount of liquid that is dispensed The default value is 43 CYCLE COUNT This entry shows the number of brew cycles that has occurred on this machine since the last time the count was...

Page 11: ...OD WASTE TRAY CAUTION UNLESS THE TANK IS LEFT TO COOL THE WATER IS EXTREMELY HOT AND CAN CUASE HARMFUL BURNS REPLACE DRAIN PLUG ENSURE HOSE CLAMP IS TIGHT AND REPOSITION DRAIN HOSE BEFORE RE FILLING T...

Page 12: ...BOARD BRACKET OUT OF MACHINE TO ACCESS TRANSFORMER REMOVE 3 8 32 NUTS TO PREPARE TANK FOR REMOVAL TWO ON TOP OF TANK ONE ON BOTTOM OF PUMP BRACKET REMOVE 2 6 32 SCREWS TO REMOVE SIDE PANEL FOR PUMP A...

Page 13: ...13 POD BREWING MECHANISM 780234 61MM and 780330 56MM...

Page 14: ...TEM NEWCO PN DESCRIPTION QTY EA 1 780230 BREW MECH MOTOR 2 2 780231 DELTROL SOLENOID 1 3 780257 780329 UPPER BREW CHAMBER 61MM UPPER BREW CHAMBER 56MM 1 4 773246 U CUP SEAL RING 1 5 780262 780314 LOWE...

Page 15: ...15 780234 TANK ASS Y 1 10 2 3 4 5 6 7 8 9...

Page 16: ...T 30A 1 2 111593 HI LIMIT THERMOSTAT 1 3 706341 PUMP ASS Y 120 VOLT 1 4 781772 PUMP ASS Y W ELBOW 1 5 780253 PUNCHED TANK W STUD 1 6 773056 AIR PUMP POD 1 7 108022 LIQUID LEVEL PROBE 1 8 151677 DUAL T...

Page 17: ...17 ELECTRICAL COMPONENTS...

Page 18: ...TH LOW WATER LEVEL CHECK FILL VALVE OR WATER SUPPLY LINE Message UPPER LOWER MOTOR ERROR BREW CHAMBER DRIVE MOTOR ERROR CHECK FOR JAM OR OBSTRUCTION IN BREW CHAMBER Message BOARD ERROR CONTROL BOARD W...

Page 19: ...FLOW ADJUSTMENT CONTROL VIEW FROM TOP OF MACHINE COVER REMOVED ONLY USED FOR ADJUSTING WATER FLOW RATE FACTORY SET CALIBRATION PUMP FLOW ADJUSTMENT CLOCKWISE DECREASE FLOW COUNTER CLOCKWISE INCREASE F...

Page 20: ...3 2 1 2 1 4 3 COFFEE PUMP FILL SOLENOID BK WH BK WH BR BK WH BR YL VIO BK VIO WH VIO BK VIO BK BK BK BK BK VIO BK VIO BK WH WH GY GY GY GY OR GY BK RD OR GY RD BK WH WH BK YL BR BR WH GY BR RD RD RD...

Page 21: ...21...

Page 22: ...22...