ELECTRICAL COMPONENTS CONT’D
ITEM #
NEWCO PN
DESCRIPTION
QTY/EA
1 780225
CONTROL
BOARD
1
2
110626
SWITCH, DPST, ON/OFF
1
3
SOLENOID FILL VALVE
1
TRANSFORMER
120VAC-24VAC
1
5 780224
DISPLAY
BOARD
1
ERROR MESSAGES
Message - "THERMISTOR ERROR"
THERMISTOR IS OPEN OR SHORTED-REPLACE PN
Message - "HIGH TEMP ERROR"
RAPID TEMPERATURE RISE-HEATER ON WITH LOW WATER LEVEL-
CHECK FILL VALVE OR WATER SUPPLY LINE
Message - "UPPER/LOWER MOTOR ERROR"
BREW CHAMBER DRIVE MOTOR ERROR-CHECK FOR JAM OR
OBSTRUCTION IN BREW CHAMBER
Message - "BOARD ERROR"
CONTROL BOARD WRITE ERROR-REPLACE BOARD IF MESSAGE
DOES NOT CLEAR PN 780225
Message - "FILL TIMEOUT ERROR"
WATER NOT REACHING LEVEL PROBE-CHECK WATER SUPPLY OR
CHECK FOR WATER LEAK
Message - "HEATER TIMEOUT ERROR"
WATER NOT HEATED DURING TIMEOUT PERIOD-CHECK HEATER
RELAY PN
OR HEATING ELEMENT PN 704166-10(1700W US) OR
704161-10 (1400W CANADA) OR HI-LIMIT THERMOSTAT PN
Summary of Contents for Fresh Cup