ADM-XF land call module
Technicaldata
ADMmanual
11
5
ADM-XF land call module
The ADM-XF controls the connected landing call panels via separate ribbon cable. The ADM-XF is installed
once in the control system and, from there, controls the buttons and direction indicators for up to 14 floors.
5.1
Technical data
Description
Value
Supply voltage
24 V DC ±10%
Typical power consumption
50 mA
Outputs
Short circuit-proof
Length x height x depth
72 x 144 x 15 mm
Temperature range: Storage & transport / operation
-20 – +70 °C / ±0 – +60 °C
Relative humidity: Storage & transport / operation
(non-condensing)
+5 – +95 % / +15 – +85 %
K1
K3
K2
X21
X14
X13
X12
X11
X10
X9
X8
X7
X6
X5
X4
X3
X2
X1
X22
J0
J1
J2
J3
J4
72
6
144
72
7
137
Fig. 5.1: ADM-XF circuit board marking
5.2
Installation and wiring
The ADM-XF is installed in the control cabinet and fixed in place there with threaded bolts. The wiring of the
landing call panels is carried out using prefabricated ribbon cable during on-site installation.
The ADM-XK is connected to the shaft bus (FST X5 and X6) and supplied via the FST X4 (X4.1: +24 V, X4.2:
GND).